2.56KWH Rack UPS Battery Module 51.2V 50AH

Model
Nature of the Manufacturer
Other
Product Category
Rack UPS Battery Module 51.2V
Place of Origin
XiAn City, ShanXi Province
Overview
YouthPOWER rack 19 inch lithium battery series is a perfect solution for residential storage facilities, with standard 51.2V / 50AH specification, up to 99% usable capacity.
Product Details

Product Introduction

1200X600(001)


YouthPOWER 19-inch series rack items including 2U-5U models 50-200Ah. Provides 2.4KWH up to 10kwh for sing module. Modular design gives end-customers the ability to choose more capacity with more units. Compatible with most off grid / hybrid inverters in the market.

Easy fastening of the buckles that minimized the installation time and cost!


Product Parameter

We are always ready to supply the first-class products and meet the various needs of the customers.

Part Number: YP 2U-5150

Brand: YouthPOWER

Battery Voltage: 51.2V

Capacity: 50AH / 2.56KWH


PDF-Datasheet: Download Here. (need to download the file)


Product Specification
Model No.YP 2U-4850
YP 2U-5150
YP 4U-48100
YP 4U-51100
YP 5U-48150
YP 5U-51150
YP 5U-48200
YP 5U-51200
Voltage48V/51.2V
Combination15S/16S 1-4P
Capacity50AH100AH150AH200AH
Energy2.4KWH5KWH7KWH10KWH
Weight23/28KG46/49KG64/72KG83/90KG
Cell3.2V 50AH UL1642
BMSBuilt - in Battery Management System
ConnectorsWaterproof connector
Dimension442x480x88mm483x460x178mm483x620x178mm483x680x178mm
Cycles (80% DOD)6000 cycles
Depeth of dischargeUpto 99%
Lifetime10 years
Standard charge20A50A50A50A
Standard discharge20A50A50A50A
Maximum continuous charge50A100A100A120A
Maximum continuous discharge50A100A100A120A
Operation temperatureCharge: 0-45℃, Discharge: -20--55℃
Storage temperatureKeep at -20 to 65℃
Protection standardIp21
Cut off voltage45V
Max.charging voltage54V
Memory effectNone
MaintenanceMaintenance free
CompatibilityCompatible with all standard oifgrid inverters and charge controllers.
Battery to inverter output sizing keep 2:1 ratio.
Warranty Period5-10 Years
RemarksYouth Power rack battery BMS must be wired in parallel only.
Wiring in series will void the warranty.
Allow max, 14 units in parallel to expand more capacity.


Product Feature

500x500-1

●Green energy

●Non-toxic, no harmful heavy metals used that can harm the environment

●Advanced BMS

●Integrated advanced BMS with smart user-friendly features.

●Fast charging

●Super-fast charging capability (90% in 1hour)

●Lighter battery weight

●Far lighter than equivalent lead acid batteries.

●Zero maintenance

●No need for maintenance

●Easy Implementation

●No need to assign extra man-power to install.

●6000Life cycles@80%DOD

●Extremely longer life cycles than lead acid batteries, Superior DOD.

●Low self-discharge

●Self-discharge is less than half that of nickel-based batteries.




For household use, night time use of stored solar energy or reducing electricity bill.

●Home solar energy storage system, hospital, school, office space charged by grid or solar

●Back-up emergency power supply when no enough grid or solar supply.

●Replaced of diesel generator to avoid noise.

●For small office, or outdoor for real independence of electricity.



1200x800(001)

1.6(002)

1.7(002)


1.8(001)


6.1



Q: Which inverter brand is ok to work with your battery units?

A:. Please find the inverter list as below for 48V series.

20220309124258bc5e1f1b9a654e899cb9a15ab5cf17e4

Q: Can you do OEM and ODM?

A: Yes, OEM and ODM are both acceptable. The material, color, style can be customized, the basic quantity we will advise after discussion.


Q: Can we use our own logo?

A: Yes, we can arrange silk print private logo according to your request. Just share with our sales engineer with your logo in AI file in advance.


Q:If there is a planned power outage, can the system last for the full power outage time?

A:Yes, but the system has to be correctly sized to begin with. These systems are capable of bridging power outages from 2 – 24 hours or (e.g. for 2 hours per day twice a day) as the battery chargers are powerful enough to recharge the battery bank to cater for the second outage on the same day (providing there is enough time between the 2 outages – at least 4-6 hours). Again, this process if fully automatic.


Q: Which items should not be powered by a backup power system or need more careful.

A: We need try to avoid connecting the following items which have high inrush currents or use a lot of power:

● Geysers

● Underfloor heating

● Stoves

● Air conditioners

● Washing machines

● Tumble driers

● Dishwashers

● Pool motors


Q : Which appliances that run well on a backup power system:

A: You can connect the following appliances to the inverter systems as long as the total power consumption does not exceed the maximum VA rating of the unit:

● Small to large Plasma or LCD TV

● DSTV and MNet decoders

● Surround sound systems

● 5 to 10 energy saver lights

● a Fan

● Fridge and deep freezer

● Home alarm system

● Automatic garage door motor

● Intercom

● Electric fence

● Microwave oven

● Small kettle

● Fax machine

● Some standard home Power tools


Similar Product Recommend