Automatic Belt Microwave Sterilization Machine Air Cooling Dry Heat Sterilizers

Model
Nature of the Manufacturer
Manufacturer
Product Category
Microwave Sterilization Machine
Place of Origin
City, Province
Overview
Product Details: Place of Origin: China Brand Name: ......
Product Details

Automatic Belt Microwave Sterilization Machine Air Cooling Dry Heat Sterilizers

Description
Product Name:Automatic Belt Type Microwave Drying And Sterilization EquipmentApplication:Dry And Sterilize Food, Medicine, Tobacco, Wood, Etc
Voltage:CustomizedFeature::High Efficiency Drying And Sterilization Machine
Cooling Method:Air Cooling, Water CoolingTemperature:0-220°C Adjustable
Usage:Food ,chemical , Herbs,etc.Energy:Electric
High Light:

Automatic Belt Microwave Sterilization Machine

,

Air Cooling Microwave Sterilization Machine

,

Microwave Dry Heat Sterilizers

Automatic Belt Type Microwave Drying And Sterilization Equipment

 

 

Scope of application:

 

Microwave sterilization equipment is suitable for the sterilization of various materials in the food field. Such as: condiments, additives, chicken powder, meat products, fish products, seafood, fruit pieces, beans, vegetables, mushrooms, flour, starch, rice flour products, soy products, pickles, braised products, feed, Nutrients and other materials.

 

Microwave sterilization can be divided into post-packaging sterilization and pre-packaging sterilization. The packaging container cannot be made of metal, and medium materials are required. Generally, plastic flexible packaging or glass is used, and engineering plastics are suitable. In order to prevent the bag from expanding during the microwave sterilization process, the equipment can apply pressure in the working chamber and adopt the back pressure sterilization process, which can prevent the loss of the bag from expanding.

 

Automatic Belt Microwave Sterilization Machine Air Cooling Dry Heat Sterilizers 0

 

 

Theory of Microwave Sterilization Equipment

 

Microwave sterilization is the result of the combined effect of the thermal effect and biological effect of the electromagnetic field. The thermal effect of microwave on bacteria is to change the protein, so that the bacteria lose the conditions for nutrition, reproduction and survival and die.

 

The biological effect of microwave on bacteria is that the microwave electric field changes the potential distribution of the cell membrane section, affects the concentration of electrons and ions around the cell membrane, and thus changes the permeability of the cell membrane. Therefore, the bacteria are malnourished, unable to metabolize normally, the cell structure and function are disordered, and growth and development are inhibited. And death.

 

In addition, the nucleic acid RNA and deoxyribonucleic acid DNA that microwave can make bacteria grow normally and stably reproduce is caused by several hydrogen bonds relaxation, breakage and recombination, thereby inducing genetic mutation, or chromosomal aberration or even breakage.

 

Automatic Belt Microwave Sterilization Machine Air Cooling Dry Heat Sterilizers 1

 

Features of Microwave Drying and Sterilization Equipment

 

1. The microwave drying and sterilization equipment has a fast heating speed:
Conventional heating, such as flame, hot air, electric heating, steam, etc., uses the principle of heat conduction, heat is transferred from the outside of the heated object to the inside, and the temperature of the center of the object is gradually increased, which is called external heating. It takes a certain amount of time to reach the temperature required for the center, and longer for substances with poor thermal conductivity.

 

Microwave sterilization is to convert the heating material province into a heating element, which is called internal heating mode. In the process of heat conduction, heating inside and outside at the same time can achieve the heating effect in a lot of time.

 

2. Microwave drying and sterilization equipment is easy to control:
The thermal inertia of microwave heating is very small. If it is controlled by a microcomputer, it is especially suitable for the automatic control of the heating process and the heating process.


3. Microwave drying and sterilization equipment is pollution-free:
Microwave energy itself does not contaminate food. Microwave has a dual sterilization effect of thermal effect and non-thermal effect, and can sterilize at low temperature. This provides a heat sterilization method for maintaining more nutrients in the food.

 

Automatic Belt Microwave Sterilization Machine Air Cooling Dry Heat Sterilizers 2

Technical Specifications

 

ModelNT-20NT-40NT-60
Working frequency2450+50MHz2450+50MHz2450+50MHz
Rated input apparent power≤25kw≤50kw≤75kw
Microwave output power≥20kw≤40kw≤60kw
Working process temperature70-20070-20070-200
Equipment cooling modeWater cooled/air cooledWater cooled/air cooledWater cooled/air cooled
Working timeContinuous 24 hoursContinuous 24 hoursContinuous 24 hours
Height of importand export material40-100mm40-100mm40-100mm
Transmission belt height600-1000mm600-1000mm600-1000mm
Transmission speed0-0.45m/min0-0.45m/min0-0.45m/min
Dehydration rate16-20 kg/h30-40 kg/h48-60 kg/h
Overall dimensions8640*1220+2200mm10960+1500+2200mm13200+1500+2200mm
Conveyor width500+100mm800+100mm800+100mm

 

 

Equipment production steps

 

Automatic Belt Microwave Sterilization Machine Air Cooling Dry Heat Sterilizers 3

Payment terms:

 

T/T, L/C or other formal import and export payment method

 

 

Packing and Shipping:

 

1. Plastic film as inner packaging

 

2. Formal export packaging or packaging according to customer requirements

 

3. Shipping by sea, land or rail.

Choose the best shipping method according to the actual situation or customer requirements

 

Automatic Belt Microwave Sterilization Machine Air Cooling Dry Heat Sterilizers 4

 

FAQ

 

Q: How long is your production cycle?

A: Usually 7-25 working days, depending on the quantity.

 

Q: Can you help design the entire process line?

A: Of course, our experienced engineers and technicians can help you arrange the layout and installation of the entire production line according to the actual situation such as your workshop layout.

 

Q: How to install?

A: Due to the epidemic, we can currently provide online guidance services by experienced engineers.

 

Q: How is the payment:

A: T/T, L/C or other formal import and export payment method

 

Q: How long is your warranty period?

A: One year after commissioning is completed.

 

Q: Will you help us if we have any problems in future production?

A: It is necessary, you can contact me through phone, WhatsApp, etc. We are always at your service. We will help resolve your issue as soon as possible.

Similar Product Recommend