GE 200NG-MAN2876-ENGas generator

Model
Nature of the Manufacturer
Other
Product Category
Gas generator
Place of Origin
City, Province
Overview
GE 200NG-MAN2876-EN
Product Details

200NG/200NGS

Natural gas Generator Set

Main configuration and features:

• Highly efficient gas engine. & AC synchronous alternator.

• Gas safety train and gas protection device against leakage.

• Cooling system suitable for ambient temperature up to 50℃.

• Strict shop test for all gensets.

• Industrial silencer with silencing ability of 12-20dB (A).

• Advanced engine control system: ECI control system including: ignition system, detonation control system ,speed control system , protection system,air/fuel ratio control system and cylinder temp.

• With cooler and Temperature Control System to make sure the unit can work normally at 50℃ environment temperature.

• Independent electrical control cabinet for remote control.

• Multi-functional control system with simple operation.

• Data communication interfaces integrated into control system.

• Monitoring battery voltage and charging automatically.

Unit type data
Fuel type

Natural gas

Equipment type

200NG/200NGS

Assembly

Power supply

+ exhaust gas heat exchanger kit + Control cabinet

Genset compliance with standard

ISO3046,ISO8528,GB2820, CE,CSA,UL,CUL

Continuous output
power modulation

50%

75%

99%

Electrical outputkW

100

284

150

423

200

537

Fuel use kW
Efficiency in mains parallel mode
Continuous output

50%

75%

99%

Electrical efficiency %

34.3

35

37.1

Current(A)/ 400V / F=0.8

Special statement:

1. The technical data are based on natural gas with a calorific value of 10 kWh/Nm³ and a methane no. > 90%

2. The technical data are based on biogas with a calorific value of 6 kWh/Nm³ and a methane no. > 60%

3. The technical data indicated is based on standard conditions according to ISO8528/1, ISO3046/1 and BS5514/1

4. The technical data is measured in standard conditions: Absolute atmospheric pressure:100kPa Ambient temperature:25°C Relative air humidity:30%

5. Rating adaptation at ambient conditions according to DIN ISO 3046/1.The tolerance for the specific fuel consumption is + 5 % at rated output.

6. Documentation technical parameters are for standard product use only and are subject to change. As this document is for pre-sale reference only, the final order is subject to the technical specifications provided.

Prime power Operating Data Insolated Mode
Synchronous alternator

Star, 3P4h

FrequencyHz

50

Power factor

0.8

Rating (F) KVA prime powerKVA

250

Generator voltageV

380

400

415

440

CurrentA

380

361

348

328

Genset performance data and manufacturing technology
Overload run-time at 1.1xSe(hour)

1

Telephone interference factor (TIF)

≤50
Voltage setting range

≥±5%

Telephone harmonious factor (THF)

≤2%,as perBS4999
Steady-state voltage deviation

≤±1%

Manufacturing technology

  • Special welded base frame, inner vibration isolators and design for whole lifting
  • With high-class paint, endurable brightness as well resistance against abrasion and defacing
  • Installation manual, operation and maintenance manual wiring program

Standards and certificate

  • ISO3046,ISO8528
  • GB2820BS5000PT99, AS1359
  • IEC34ISO9001:2008 quality system certification
Transient-state voltage deviation

-15%~20%

Voltage recovery time (s)

≤4

Voltage unbalance

1%

Steady-state frequency regulation

±0.5%

Transient -state frequency regulation

-15%~12%

Frequency recovery time (s)

≤3

Steady-state frequency band

0.5%

Recovery time response (s)

0.5

Line Voltage Waveform Sine Distortion Ratio

≤ 5%

Emission data[1]
Exhaust flow rate1120 kg/h
Exhaust temperature60℃~120℃
Maximum allowable exhaust back pressure2.5Kpa
Emission: (Option) NOx: < 500 mg/Nm³ at 5% residual oxygen
CO≤600 mg/ Nm³ at 5% residual oxygen
NMHC≤125 mg/ Nm³ at 5% residual oxygen
H2S≤20 mg/ Nm3
Environmental noise
Sound pressure level at a distance of up to 1 m(based on surroundings)

87dB (A) / Open Type 75dB (A) / Silent Type

[1] Emission values downstream of catalytic converter based on dry exhaust.

Gas Data
Fuel

[1]

Natural gas

Gas intake pressure

5Kpa~50Kpa

Methane volume content

≥ 80%

Low heat value(LHV)

Hu ≥ 31.4MJ/Nm3

Gas Consumption per hour at 50% load at 75% load at 99% load

29 m3

43.5 m3

55 m3

[1] After the Natural gas components need to be provided by users, the relevant data of the technical manual will be revised.Gas hoses are ECER110 approved. Components in the gas train meet Directive 90/356/EWG.
Service
Oil level (ambient temperature is higher than minus 5°C/ ambient temperature is lower than minus 5°C)

API 15W-40 CF4 /API 10W-30 CF4

Lubricating oil capacity min./max.

30 L/41L

Coolant capacity

40 L

Coolant type

50% softened water and 50% anti-freezing solution (ethylene glycol, with the concentration of the anti-freezing solution between 40%-68% )

[2]

Maintenance (hour)

8000

[2] maintenance time shall be subject to the application environment, fuel quality as well as maintenance intervals; the data is not offered as the basis for sales.

AC alternator performance data Efficient gas engine
Alternator brand STAMFORD Engine brand

MAN

Motor type HCI 444C Engine model

E 2876 LE 302

Voltage(V)380 400 415440Engine type

6 cylinders inline, Exhaust turbocharger with water-cooled turbine

housing

Rating (F) KW prime power

Bore x stroke (mm)

128mm×166mm

Rating (F) KVA prime power 250 Displacement (L)

12.82

Alternator efficiency (%)94.694.6 94.694.6Compression ratio

11

Power factor

0.8

Rated output power

210kW/1500rpm

Wiring connection

D/Y

Oil consumption max.(kg/h)

0.15

Rotor insulation class

H class

Min Intake flow, (kg/h)

Temperature-rise rating

F class

Ignition method

Electrically controlled single cylinder independent high-energy ignition

Excitation method Brush-less Fuel control mode

Equivalent combustion, closed loop control

Rated speed(min-1) 1500 Speed regulation mode

Electronic governor

Housing protection

IP23

Alternator compliance withGB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standard.

In case of nominal mains voltage variations by ± 2%, an automatic voltage regulator (AVR) must be used.

Scope of Supply
EngineAlternator Canopy and base Electrical cabinet
Gas engine Ignition system Lambda controllerElectronic governor actuatorElectrical start motorBattery system AC alternatorH class insulationIP55 protectionAVR voltage regulatorPF control Steel sheel base frameEngine bracket Vibration isolators Soundproof canopyDust filtration Air circuit breaker7-inch touch screenCommunication interfaces Electrical switch cabinetAuto charging system
Gas supply systemLubrication systemStandard voltageInduction/exhaust system
Gas safety trainGas leakage protectionAir/fuel mixerOil filterDaily auxiliary oil tankAuto refilling oil system380/220V400/230V415/240V Air filterExhaust silencerExhaust bellows
Gas Train Service and documents
Manual cut-off valve2~7kPa pressure gaugeGas filterSafety Solenoid valve (anti-explosion type is optional) pressure regulatorFlame arrestor as optionTools package Engine operation Installation and operation manual Gas quality specification Maintenance manual Control system manual Software manual After service guide Parts manual Standard package
Optional configuration
EngineAlternatorLubrication system
Coarse air filterBackfire safety control valveWater heaterSynchron – generator Brand: Stamford, LeroySomer, MECCTreatments against humidity and corrosionBrand new oil tank with large capacityOil consumption measuring gaugeFuel pumpOil heater
Electrical systemGas supply systemVoltage
Remote monitoring Grid-connection remote control sensorGas flow gaugeGas filtrationPressure reducer gas pretreatment alarm system220V230V240V
Service and documentsExhaust systemHeat exchange system
Service toolsMaintenance and service partsThree-way catalytic converterGuard shield from touchResidential silencerExhaust gas treatmentEmergency radiatorElectric heaterThermal storage tankPumpFlowmeter

SAC-300 Control system

Programmable control system is adopted with touch screen display , and various functions, including: engine protection and control. paralleling between gensets or gensets and grid, and CHP control functions, as well as communication functions. etc.

Main advantages

→ Premium gen-set controller for both single and multiple gensets operating in standby or parallel modes.

→ Support of complex applications for power production in data centres, hospitals, banks and also CHP applications.

→ Support of engines both with electronic unit – ECU and mechanical engines.

→ Complete control of the engine, alternator and controlled technology from one unit provides access to all measured data in a coherent and time corresponding way.

→ Wide range of communication interfaces allows smooth integration into local monitoring systems (BMS, etc.)

→ Internal built-in PLC interpreter allows you to configure customised logic to meet demanding customer requirements on your own without extra programming knowledge and in a fast way.

→ Convenient remote control and service

→ Enhanced stability and safety

Main functions
Engine monitor:coolant, lubrication, exhaust, battery Fuel gas inlet loop monitoring Parallel connection and power distribution automaticallyVoltage and power factor controlUnit monitoring and protectionModbus communication protocol based on RS232 and RS485 interfaces 1000 history events log Remote control

Parallel and grid connection system

Protection with IP44Set Input, Output, Alarm and Time Automatic failure state emergency stop and fault display LCD display functionExtensible FunctionATS (Automatic Transfer Switch)GPRS function with SMSUtomatic floating charger Gas leaking detection
Standard configuration
Engine Control: Lambda closed loop controlIgnition systemElectronic governor actuatorStart up control speed control load controlGenerator Control:Power control RPM control (synchronous) Load distribution (island mode) Voltage control Voltage tracking (synchronous) Voltage control (island mode)Reactive power distribution(island mode) Other controls: Oil filling automaticallyWater pump controlValve control Fan control
Early warning monitoring
battery voltageAlternator data:U、I、Hz、kW、 kVA、kVAr、PF、kWh、kVAhGenset frequencyEngine SpeedEngine running timeInlet pressure temperatureOil pressureOil TemperatureCoolant temperatureMeasurement of oxygen content in exhaust gasIgnition status inspectionCoolant temperatureFuel gas inlet pressurePressure and temperature of the heat exchanger system
Protection functions
Engine protection Low oil pressureSpeed protectionOver speed/short speedStarting failureSpeed signal lost Alternator protection- 2xReverse power- 2xOverload- 4xOvercurrent- 1xOvervoltage- 1xUndervoltage- 1xOver/under frequency- 1xUnbalanced current Busbar/mains protection - 1xOvervoltage- 1xUndervoltage- 1xOver/under frequency- 1xPhase sequence - 1xROCOF alarm System protection Alarm Protection FunctionHigh coolant temperatureCharge faultEmergency Stop

 

Dimensions are for reference only.

Paints, Dimensions and Weights of the Genset
Genset size (length * width * height) mm3880×1345×2020
Genset dry weight(Open Type) kg3350
Spraying ProcessHigh quality powder coating(RAL 9016 & RAL 5017 )
Dimensions are for reference only.
200kW Cogeneration Unit — 200NC