GE 1000NG&NGS-G9620-M-EN-400VGas generator

Model
Nature of the Manufacturer
Other
Product Category
Gas generator
Place of Origin
City, Province
Overview
GE 1000NG&NGS-G9620-M-EN-400V
Product Details

1000NG/1000NGS

Natural gas Generator Set

Main configuration and features:

• Highly efficient gas engine. & AC synchronous alternator.

• Gas safety train and gas protection device against leakage.

• Cooling system suitable for ambient temperature up to 50℃.

• Strict shop test for all gensets.

• Industrial silencer with silencing ability of 12-20dB(A).

• Advanced engine control system: ECI control system including: ignition system, detonation control system ,speed control system , protection system,air/fuel ratio control system and cylinder temp.

• With cooler and Temperature Control System to make sure the unit can work normally at 50℃ environment temperature.

• Independent electrical control cabinet for remote control.

• Multi-functional control system with simple operation.

• Data communication interfaces integrated into control system.

• Monitoring battery voltage and charging automatically.

Unit type data
Fuel type

Natural gas

Equipment type

1000NG/1000NGS

Assembly

Power supply

+ Heat Dissipation System+ Control cabinet

Genset compliance with standard

ISO3046,ISO8528,GB2820, CE,CSA,UL,CUL

Continuous output
power modulation

50%

75%

99%

Electrical outputkW

500

1253

750

1850

1000

2448

Fuel use kW
Efficiency in mains parallel mode
Continuous output

50%

75%

99%

Electrical efficiency %

40

40.5

41

Current(A)/ 400V / F=0.8

902

1353

1804

Special statement:

1. The technical data are based on natural gas with a calorific value of 10 kWh/Nm³ and a methane no. > 90%

2. The technical data indicated is based on standard conditions according to ISO8528/1, ISO3046/1 and BS5514/1

3. The technical data is measured in standard conditions: Absolute atmospheric pressure:100kPa Ambient temperature:25°C Relative air humidity:30%

4. Rating adaptation at ambient conditions according to DIN ISO 3046/1.The tolerance for the specific fuel consumption is + 5 % at rated output.

5. Dimension and weight above are just for standard product and may be subject to change. As this document is used only for presale reference, take the specification supplied by Smart Action before ordering as final.

6. The applicable ambient temperature is -30 ° C ~ 50 ° C; when the ambient temperature exceeds 40 ° C, the rated power is reduced by 3% for every 5 ° C increase in temperature. Applicable altitude is less than 3000 meters; when the altitude exceeds 500 meters, the rated power is reduced by 5% for every 500 meters of height.

Prime power Operating Data Insolated Mode
Synchronous alternator

Star, 3P4h

FrequencyHz

50

Power factor

0.8

Rating (F) KVA prime powerKVA

1250

Generator voltageV

400

CurrentA

1804

Genset performance data and manufacturing technology
Overload run-time at 1.1xSe(hour)

1

Telephone interference factor (TIF)

≤50
Voltage setting range

≥±5%

Telephone harmonious factor (THF)

≤2%,as perBS4999
Steady-state voltage deviation

≤±2%

Manufacturing technology

  • Special welded base frame, inner vibration isolators and design for whole lifting
  • With high-class paint, endurable brightness as well resistance against abrasion and defacing
  • Installation manual, operation and maintenance manual wiring program

Standards and certificate

  • ISO3046,ISO8528
  • GB2820BS5000PT99, AS1359
  • IEC34ISO9001:2008 quality system certification
Transient-state voltage deviation

-12%~18%

Voltage recovery time (s)

≤2

Voltage unbalance

1%

Steady-state frequency regulation

±1.5%

Transient -state frequency regulation

-15%~10%

Frequency recovery time (s)

≤5

Steady-state frequency band

1.5%

Recovery time response (s)

0.5

Line Voltage Waveform Sine Distortion Ratio

≤ 5%

Emission data[1]
Exhaust flow rate4544 kg/h
Exhaust temperature480℃
Maximum allowable exhaust back pressure4 Kpa
Emission: (Option) NOx: ≤500 mg/Nm³ at 5% residual oxygen
CO≤600 mg/ Nm³ at 5% residual oxygen
NMHC≤125 mg/ Nm³ at 5% residual oxygen
H2S≤20 mg/ Nm3
Environmental noise
Sound pressure level at a distance of up to 7 m(based on surroundings)

98dB (A) / Open Type 82dB (A) / Silent Type

[1] Emission values downstream of catalytic converter based on dry exhaust.

API 15W-40 CF4 /API 10W-30 CF4
Gas Data
Fuel

[1]

Natural gas

Gas intake pressure

5Kpa~50Kpa

Methane volume content

≥ 80%

Low heat value(LHV)

Hu ≥ 31.4MJ/Nm3

Gas Consumption per hour at 50% load at 75% load at 99% load

125 m3

185 m3

247 m3

[1] After the Natural gas components need to be provided by users, the relevant data of the technical manual will be revised.Gas hoses are ECER110 approved. Components in the gas train meet Directive 90/356/EWG.
Service
Oil level (ambient temperature is higher than minus 5°C/ ambient temperature is[2] lower than minus 5°C)
Lubricating oil capacity min./max.

N/A

Coolant capacity

N/A

Coolant type

50% softened water and 50% anti-freezing solution (ethylene glycol, with the concentration of the anti-freezing solution between 40%-68% )

installation room ventilation (inlet air volume flow )

>15000 m³/h

[2] The oil standard refers to factors such as local ambient temperature and air pressure.

AC alternator performance data Efficient gas engine
Alternator brand

MECC ALTE

Engine brand

LIEBHERR

Motor type

ECO43-2L/4A

Engine model

G9620

Voltage(V)

400

Engine type

V-20 cylinders , turbocharger with intercooler

Rating (H) KW prime power

1040

Bore x stroke

135mm×170mm

Rating (H) KVA prime power 1300Displacement (L)

48.7

Alternator efficiency (%)

96

Compression ratio

N/A

Power factor

0.8

Rated output power

1060kW/1500rpm

Wiring connection

D/Y

Oil consumption max.

0.3 g/kw*h

Rotor insulation class

H class

Min Intake flow, (kg/h)

4365

Temperature-rise rating

F class

Ignition method

Electrically controlled single cylinder independent high-energy ignition

Excitation method

Brush-less

Fuel control mode

Equivalent combustion, closed loop control

Rated speed(min-1)

1500

Speed regulation mode

Electronic governor

Housing protection

IP23

Alternator compliance withGB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standard.

In case of nominal mains voltage variations by ± 2%, an automatic voltage regulator (AVR) must be used.

Scope of Supply
EngineAlternator Canopy and base Electrical cabinet
Gas engine Ignition system Lambda controllerElectronic governor actuatorElectrical start motorBattery systemAC alternatorH class insulationIP55 protectionAVR voltage regulatorPF control Steel sheel base frameEngine bracket Vibration isolators Soundproof canopy (optional)Dust filtration (optional)Air circuit breaker7-inch touch screenCommunication interfaces Electrical switch cabinetAuto charging system
Gas supply systemLubrication systemStandard voltageInduction/exhaust system
Gas safety trainGas leakage protectionAir/fuel mixerOil filterDaily auxiliary oil tank (optional)Auto refilling oil system380/220V400/230V415/240V Air filterExhaust silencerExhaust bellows
Gas Train Service and documents
Manual cut-off valve2~7kPa pressure gaugeGas filterSafety Solenoid valve (anti-explosion type is optional) pressure regulatorFlame arrestor as optionTools package Engine operation Installation and operation manual Gas quality specification Maintenance manual Control system manual Software manual After service guide Parts manual Standard package
Optional configuration
EngineAlternatorLubrication system
Coarse air filterBackfire safety control valveWater heater Generator Brand: Stamford, Leroy-Somer, MECCTreatments against humidity and corrosionBrand new oil tank with large capacityOil consumption measuring gaugeFuel pumpOil heater
Electrical systemGas supply systemVoltage
Remote monitoring Grid-connection remote control sensorGas flow gaugeGas filtrationPressure reducer gas pretreatment alarm system220V230V240V
Service and documentsExhaust systemHeat exchange system
Service toolsMaintenance and service partsThree-way catalytic converterGuard shield from touchResidential silencerExhaust gas treatmentEmergency radiatorElectric heaterHeat recovery systemThermal storage tank

SAC-200 Control system

Programmable control system is adopted with touch screen display , and various functions, including: engine protection and control, paralleling between gensets or gensets and grid, as well as communication functions. etc.

Main advantages

→ Premium gen-set controller for both single and multiple gensets operating in standby or parallel modes.

→ Support of complex applications for power production in data centres, hospitals, banks and also CHP applications.

→ Support of engines both with electronic unit – ECU and mechanical engines.

→ Complete control of the engine, alternator and controlled technology from one unit provides access to all measured data in a coherent and time corresponding way.

→ Wide range of communication interfaces allows smooth integration into local monitoring systems (BMS, etc.)

→ Internal built-in PLC interpreter allows you to configure customised logic to meet demanding customer requirements on your own without extra programming knowledge and in a fast way.

→ Convenient remote control and service

→ Enhanced stability and safety

Main functions
Engine running timeAlarm Protection Function

  • low oil pressure
  • high coolant temperature

Emergency Stop

  • emergency stop button pressed
  • speed signal lost

Engine monitor:coolant, lubrication, Intake, exhaust

Voltage and power factor control

12V or 24V DC StartingRemote Control Interface as an optionAutomatic Start/Stop Control SwitchSet Input, Output, Alarm and TimeNumbers Control Input, Relays Control OutputAutomatic failure state emergency stop and fault display battery voltage genset frequencyProtection with IP44Gas leaking detection
Standard configuration
Engine Control: Lambda closed loop controlIgnition systemElectronic governor actuatorStart up control speed control load controlGenerator Control:Power control RPM control (synchronous) Load distribution (island mode) Voltage control Voltage tracking (synchronous) Voltage control (island mode)Reactive power distribution(island mode) Other controls: Oil filling automaticallyIntake Valve controlFan control
Early warning monitoring
battery voltageAlternator data:U、I、Hz、kW、 kVA、kVAr、PF、kWh、kVAhGenset frequencyEngine SpeedEngine running timeInlet pressure temperatureOil pressureCoolant temperatureMeasurement of oxygen content in exhaust gasIgnition status inspectionCoolant temperatureFuel gas inlet pressure
Protection functions
Engine protection Low oil pressureSpeed protectionOver speed/short speedStarting failureSpeed signal lost Alternator protection

  • Reverse power
  • Overload
  • Overcurrent
  • Overvoltage
  • Under voltage
  • Over/under frequency
  • Unbalanced current
Busbar/mains protection

  • Overvoltage
  • Under voltage
  • Over/under frequency
  • Phase sequence
  • ROCOF alarm
System protection Alarm Protection FunctionHigh coolant temperatureCharge faultEmergency Stop
Paints, Dimensions and Weights of the Genset—1000NG
Genset size (length * width * height) mm5200×2000×2400
Genset dry weight(Open Type) kg8200
Spraying ProcessHigh quality powder coating(RAL 9016 & RAL 5017 & RAL 9017 )
Paints, Dimensions and Weights of the Genset—1000NGS
Genset size (length * width * height) mm12192×2438×2896(Container)
Genset dry weight(Silent Type) kg16000(Container)
Spraying ProcessHigh quality powder coating(RAL 9016 & RAL 5017 & RAL 9017 )

Dimensions are for reference only.