Welcome Customer !

Membership

Fujian New Hongfu Motor Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 发电机组

Xwboo>Products
Product Categories

Fujian New Hongfu Motor Co., Ltd.Free·1YRS

  • E-mail

    director@hongfumotor.com

  • Phone

    0086-591-83973021

  • Address

    No.6 Jianye Road Tongxin Economic Development Zone Zhenghe County Nanping City Fujian Province China

Contact Now

GE 1000NG&SA1000NGS-T12-M-EN (Steam)Gas generator

Model
Nature of the Manufacturer
Other
Product Category
Gas generator
Place of Origin
City, Province
Overview
GE 1000NG&SA1000NGS-T12-M-EN (Steam)
Product Details

1000NGS/1000NG

Natural gas Generator Set

Main configuration and features:

• Highly efficient gas engine.

• AC synchronous alternator.

• Gas safety train and gas protection device against leakage.

• Cooling system suitable for ambient temperature up to 50℃.

• Strict shop test for all gensets.

• Industrial silencer with silencing ability of 12-20dB(A).

• Advanced engine control system: ECI control system including: ignition system, detonation control system ,speed control system , protection system,air/fuel ratio control system and cylinder temp.

• With cooler and Temperature Control System to make sure the unit can work normally at 50℃ environment temperature.

• Independent electrical control cabinet for remote control.

• Multi-functional control system with simple operation.

• Data communication interfaces integrated into control system.

• Monitoring battery voltage and charging automatically.

• Use safe and efficient steam boiler of which efficiency up to 92% and service life up to 20 years.

Unit type data
Fuel type

Natural gas

Equipment type

1000NGS/1000NG

Assembly

Power supply

+ Heat exchange system + The fume recovery steam boiler

Continuous output
Fuel type

Natural gas

power modulation

50%

75%

99%

Electrical outputkW

600

440

295

224

1505

900

635

455

350

2215

1000

840

645

479

2860

Coolant heat [1]kW
Exhaust gas heat (at 120 ℃)kW
Steam boiler heat output(max.)[2]kW
Energy inputkW

[1] Suppose the water return temperature from User is 60℃.

[2] The data is calculated under the condition of no circulating steam, and the temperature of exhaust for the boiler is 210°C.The data is influenced by the installation process, application way and environment.

Special statement:

1、 The technical data are based on natural gas with a calorific value of 10 kWh/Nm³ and a methane no. > 90%

2、 The technical data indicated is based on standard conditions according to ISO8528/1, ISO3046/1 and BS5514/1

Rated adjustment is made under the condition complies with DIN ISO 3046/1. In rated output condition, the tolerance of gas consumption is 5%, and the tolerance of steam production is ±8%.

Efficiency in mains parallel mode
Electrical efficiency %

33.4

29.2

14.8

77.4

34.5

28.6

15.8

78.9

35.1

29.3

16.7

81.1

Coolant Heat efficiency (max.)%
Steam boiler efficiency (max.)[2]%
Overall efficiency %
Steam boiler
Inlet temperatureWater or Steam℃

143

Inlet pressureAbsolute pressureMpa

0.4

Working temperatureSteam℃

151

Working pressureAbsolute pressureMpa

0.51

Rated evaporation(Inlet medium steam)Standard / Max.kg/h

53999~115510[2]

Rated evaporation(Inlet medium water)Standard / Max.kg/h

373~1798[3]

Thermal efficiency

%

16.7

Fume inlet temperatureMax.℃

520

Fume outlet temperatureMin.℃

210

Fume recovery standard temperature difference return/forward

K

310

Working mediumstandard

Water / Steam

Coolant filling quantityWater / Max

L

1000

Min. boiler coolant circulation quantityWaterkg/h

100

Highest pressure Mpa

1.25

Highest temperature ℃

250

[2] The data is the max evaporation made of recycling remaining exhaust gas under the condition of circulating steam.

[3] The data is calculated under the condition of no circulating steam, and the temperature of water supplement for the boiler is 20°C.

 

Special statement:

1、The technical data is measured in standard conditions: Absolute atmospheric pressure:100kPa

Ambient temperature:25°C Relative air humidity:30%

2、Rating adaptation at ambient conditions according to DIN ISO 3046/1.The tolerance for the specific fuel consumption is + 5 % at rated output.

3、The boiler is designed, produced and tested according to GB/T150.1-2011~GB/T150.4-2011 “Pressure Vessel" and GB/T151-2014 “Heat Exchanger".

Dimension and weight above are just for standard product and may be subject to change. As this document is used only for presale reference, take the specification supplied by Smart Action before ordering as final.

Gas Data
Fuel

[3]

Natural gas

Gas intake pressure

3.5Kpa~50Kpa & ≥4.5bar

Methane volume content

≥ 80%

Low heat value(LHV)

Hu ≥ 31.4MJ/Nm3

Gas Consumption per hour at 50% load at 75% load at 99% load

155 m3

225 m3

300 m3

[3] The relevant data of the technical manual will be revised after the natural gas components being supplied by User.Special statement:1、The technical data are based on natural gas with a calorific value of 10 kWh/Nm³ and a methane no. > 90%2、The technical data indicated is based on standard conditions according to ISO8528/1, ISO3046/1 and BS5514/13、The technical data is measured in standard conditions: Absolute atmospheric pressure:100kPa Ambient temperature:25°C Relative air humidity:30%4、Rating adaptation at ambient conditions according to DIN ISO 3046/1.The tolerance for the specific fuel consumption is + 5 % at rated output.
Emission data[3]
Exhaust flow rate ,moist [4]

5190 kg/h

Exhaust flow rate ,dry

4152 Nm3/h

Exhaust temperature

220℃~210℃

Maximum allowable exhaust back pressure

4.0Kpa

Genset compliance with standard Emission:

ISO3046,ISO8528,GB2820, CE,CSA,UL,CUL

Standard

SCR(Option)

NOx, at 5% residual oxygen&99% load

< 500 mg/Nm³

< 250 mg/Nm³

CO, at 5% residual oxygen&99% load

≤ 600 mg/Nm3

≤ 300 mg/Nm3

Environmental noise
Sound pressure level at a distance of up to 7 m(based on surroundings)SA1000NG/89dB (A) & SA1000NGS/75dB (A)

 

[3] Emission values downstream of catalytic converter based on dry exhaust.

Standard conditions TA-LUFT: Air temperature: 0 °C, Atmospheric pressure absolute: 100 kPa。

Prime power Operating Data Mode
Synchronous alternator

Star, 3P4h

FrequencyHz

50

Rating (F) KVA prime powerKVA

1500

Power factor

0.8

Generator voltageV

380

400

415

440

CurrentA

2279

2165

2086

1968

Alternator compliance withGB755, BS5000, VDE0530, NEMAMG1-22, IED34-1, CSA22.2 and AS1359 standard.

In case of nominal mains voltage variations by ± 2%, an automatic voltage regulator (AVR) must be used.

Genset performance data and manufacturing technology
Overload run-time at 1.1xSe(hour)

1

Telephone interference factor (TIF)

≤50
Steady-state voltage deviation

≤±1%

Telephone harmonious factor (THF)

≤2%,as perBS4999
Transient-state voltage deviation

-15%~20%

Manufacturing technology

  • Special welded base frame, inner vibration isolators and design for whole lifting
  • With high-class paint, endurable brightness as well resistance against abrasion and defacing
  • Installation manual, operation and maintenance manual wiring program

Standards and certificate

  • ISO3046,ISO8528
  • GB2820BS5000PT99, AS1359
  • IEC34ISO9001:2008 quality system certification
Voltage recovery time (s)

≤4

Voltage fluctuation

1%

Steady-state frequency regulation

±0.5%

Transient -state frequency regulation

±5%

Frequency recovery time (s)

≤3

Steady-state frequency band

0.5%

Recovery time response (s)

0.5

AC alternator performance dataEfficient gas engine
Alternator brandMECCEngine brandCNHTC
Motor typeECO38 1L4AEngine modelSTEYR T12
Rated output power (kVA)250Engine type6 cylinders inline, turbocharger with intercooler
Alternator efficiency93.40%Bore x stroke (mm)126mm×155mm
Power factor0.8Displacement (L)11.6
Wiring connectionD/YCompression ratio11
Rotor insulation classH级Rated output power235kW/1500rpm
Excitation methodBrush-lessOil consumption max.≤0.3 g/kW.hr
Voltage(V)380/400/415/440Ignition method Electrically controlled single cylinder independent high-energy igni-
Rated speed(min-1)1500Fuel control modeLean combustion, closed loop control
Housing protectionIP23Speed regulation modeElectronic governor
Service
Oil level (ambient temperature is higher than minus 5°C/ ambient temperature is lower than minus 5°C)API 15W-40 CF4 API 10W-30 CF4
Lubricating oil capacity (min./max.) 35 L / 37 L
Added fresh oil tank N/A
Coolant capacity

5 L (Min. mixture cooling water circulation quantity LT)

40 L (Min. engine coolant circulation quantity)

Coolant type

50% softened water and 50% anti-freezing solution (ethylene glycol, with the concentration of the anti-freezing solution between 35%-68% )

Supply air temperature

10℃~45℃

installation room ventilation (inlet air volume flow )

>15000 m³/h

 

Scope of Supply
EngineAlternator Canopy and base Electrical cabinet
Gas engine Ignition system Lambda controllerElectronic governor actuatorElectrical start motorBattery systemAC alternatorH class insulationIP55 protectionAVR voltage regulatorPF control Steel sheel base frameEngine bracket Vibration isolators Soundproof canopy (optional)Dust filtration (optional)Air circuit breaker7-inch touch screenCommunication interfaces Electrical switch cabinetAuto charging system
Gas supply systemLubrication systemStandard voltageInduction/exhaust system
Gas safety trainGas leakage protectionAir/fuel mixerOil filterDaily auxiliary oil tank (optional)Auto refilling oil system380/220V400/230V415/240V Air filterExhaust silencerExhaust bellows
Gas Train Service and documents
Manual cut-off valve2~7kPa pressure gaugeGas filterSafety Solenoid valve (anti-explosion type is optional) pressure regulatorFlame arrestor as optionTools package Engine operation Installation and operation manual Gas quality specification Maintenance manual Control system manual Software manual After service guide Parts manual Standard package
Optional configuration

 

EngineAlternatorLubrication system
Coarse air filterBackfire safety control valveWater heater Generator Brand: Stamford, Leroy-Somer,MECCTreatments against humidity and corrosionBrand new oil tank with large capacityOil consumption measuring gaugeFuel pumpOil heater
Electrical systemGas supply systemVoltage
Remote monitoring Grid-connection remote control sensorGas flow gaugeGas filtrationPressure reducer gas pretreatment alarm system220V230V240V
Service and documentsExhaust systemHeat exchange system
Service toolsMaintenance and service partsThree-way catalytic converterGuard shield from touchResidential silencerExhaust gas treatmentEmergency radiatorElectric heaterHeat recovery systemThermal storage tank

SAC-200 Control system

Programmable control system is adopted with touch screen display , and various functions, including: engine protection and control, paralleling between gensets or gensets and grid, as well as communication functions. etc.

Main advantages

→ Premium gen-set controller for both single and multiple gensets operating in standby or parallel modes.

→ Support of complex applications for power production in data centres, hospitals, banks and also CHP applications.

→ Support of engines both with electronic unit – ECU and mechanical engines.

→ Complete control of the engine, alternator and controlled technology from one unit provides access to all measured data in a coherent and time corresponding way.

→ Wide range of communication interfaces allows smooth integration into local monitoring systems (BMS, etc.)

→ Internal built-in PLC interpreter allows you to configure customised logic to meet demanding customer requirements on your own without extra programming knowledge and in a fast way.

→ Convenient remote control and service

Main functions
Engine running timeAlarm Protection Function

  • low oil pressure
  • high coolant temperature

Emergency Stop

  • emergency stop button pressed
  • speed signal lost

Engine monitor:coolant, lubrication, Intake, exhaust

Voltage and power factor control

12V or 24V DC StartingRemote Control Interface as an optionAutomatic Start/Stop Control SwitchSet Input, Output, Alarm and TimeNumbers Control Input, Relays Control OutputAutomatic failure state emergency stop and fault display battery voltage genset frequencyProtection with IP44Gas leaking detection
Standard configuration
Engine Control: Lambda closed loop controlIgnition systemElectronic governor actuatorStart up control speed control load controlGenerator Control:Power control RPM control (synchronous) Load distribution (island mode) Voltage control Voltage tracking (synchronous) Voltage control (island mode)Reactive power distribution(island mode) Other controls: Oil filling automaticallyIntake Valve controlFan control
Early warning monitoring
battery voltageAlternator data:U、I、Hz、kW、 kVA、kVAr、PF、kWh、kVAhGenset frequencyEngine SpeedEngine running timeInlet pressure temperatureOil pressureCoolant temperatureMeasurement of oxygen content in exhaust gasIgnition status inspectionCoolant temperatureFuel gas inlet pressure
Protection functions
Engine protection Low oil pressureSpeed protectionOver speed/short speedStarting failureSpeed signal lost Alternator protection

  • Reverse power
  • Overload
  • Overcurrent
  • Overvoltage
  • Under voltage
  • Over/under frequency
  • Unbalanced current
Busbar/mains protection

  • Overvoltage
  • Under voltage
  • Over/under frequency
  • Phase sequence
  • ROCOF alarm
System protection Alarm Protection FunctionHigh coolant temperatureCharge faultEmergency Stop

Paints, Dimensions and Weights of the Genset —1000NGS

Genset size (length * width * height) mm12192×2435×5500(Container)
Genset dry weight(Open Type) kg 22000(Container
Spraying Process High quality powder coating(RAL 9016))

Dimensions are for reference only.

1000kW Natural gas Generator Set— Silent Type



  • Similar Product Recommend