The OMP600 is a compact, high-accuracy touch probe that offers all the benefits of automated job set-up as well as the ability to measure complex 3D part geometries on CNC machining centres, including multi-tasking machines.With patented RENGAGE™ strain gauge technology and interference-resistant optical transmission, the OMP600 provides the same superior performance found in all Renishaw high-accuracy probes.
KEY FEATURES AND BENEFITS
Unbeatable 3D accuracy and repeatability enables reliable on-machine gauging/measurement
Improved accuracy with long styli means difficult parts can be probed more easily
Ultra-low trigger force for delicate work helps eliminate possible surface and form damage
Compact design enables better access in restricted spaces and small machines
Robust, even in the harshest environment, means reliable measurement and long service life
DIMENSIONS

OMP600 SPECIFICATION
| Optical setting | Modulated | Legacy |
| Principal application | Workpiece inspection and job set-up on all sizes of machining centres and small to medium multi-tasking machines. |
| ransmission type | 360° infrared optical transmission (modulated or legacy) |
| Compatible interfaces | OMI-2, OMI-2T, OMI-2H, OMI-2C or OSI with OMM-2 or OMM-2C | OMI, OMM with MI 12 |
| perating range | Up to 6m (19.7 ft) |
| Recommended styli | High modulus carbon fibre, lengths 50 mm (1.97 in) to 200 mm (7.88 in) |
| Weight without shank (including batteries) | 1029 g (36.30 oz) |
| Switch-on/switch-off options | Optical on → Optical off or timer off Spin on → Spin off or timer off Shank switch on → Shank switch off |
Battery life (2 × AA 3.6 V lithium-thionyl chloride) | Standby life | 800 days maximum, dependent on switch-on/switch-off option. |
Continuous use low power | 380 hours maximum, dependent on switch-on / switch-off option. | 410 hours maximum, dependent on switch-on / switch-off option. |
| Sense directions | ±X, ±Y, +Z |
| Unidirectional repeatability | 0.25 μm (10 μin) 2s – 50 mm (1.97 in) stylus length (see note 1) 0.35 μm (14 μin) 2s – 100 mm (3.94 in) stylus length |
| X,Y(2D) form measurement deviation | ±0.25 μm (10 μin) – 50 mm (1.97 in) stylus length (see note 1) ±0.25 μm (10 μin) – 100 mm (3.94 in) stylus length |
| X, Y, Z (3D) form measurement deviation | ±1.00 μm (40 μin) – 50 mm (1.97 in) stylus length (see note 1) ±1.75 μm (70 μin) – 100 mm (3.94 in) stylus length |
Stylus trigger force(see notes 2 and 5) XY plane (typical minimum) +Z direction (typical minimum) | 0.15 N,15 gf(0.54 ozf) 1.75 N,178 gf(6.03 ozf) |
Stylus overtravel force XY plane (typical minimum) +Z direction (typical minimum) | 3.05 N,311 gf(10.98 ozf)(see note 3) 10.69 N,1090 gf(38.51 ozf)(see note 4) |
| Minimum probing speed | 3 mm/min(0.12 in/min) |
| Sealing | IPX8(EN/IEC 60529) |
| Operating temperature | +5 °C to +55 °C (+41 °F to +131 °F) |
PRODUCT SHOW