Welcome Customer !

Membership

KAYCAN INSTRUMENT (Dalian) Co.,Ltd
Free Member ·1YRS
,
Other

Main Products: 仪器仪表

Xwboo>Products
Product Categories

KAYCAN INSTRUMENT (Dalian) Co.,LtdFree·1YRS

  • E-mail

    jimmychou@kaycantest.com;info@kaycantest.com

  • Phone

    +86-411-86315116

  • Address

    DAXINZHAIZI village, Ganjingzi District, Dalian,Liaoning province China.

Contact Now

KN-6595 Rotary Disc Electrode Atomic Emission Spectrometer (ROE-AES)

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
KN-6595 Rotary Disc Electrode Atomic Emission Spectrometer (ROE-AES)
Product Details

D6728.png

KN-6595 Rotary Disc Electrode Atomic Emission Spectrometer (ROE-AES)

1, Product introduction
KN-6595 Rotary Disc Electrode Atomic Emission Spectrometer (ROE -AES) which is capable of directly testing the contents of various metallic elements in liquid samples, such as lubricating oil, hydraulic oil, fuel oil, and etc., and finishing the analysis of various elements with a single injection with a single injection within 2 minutes. No sample pretreatments, auxiliary gas or cooling water is needed before and during the instrument is operating. Because of the strong adaptability to the environment, this instrument can be operated in warship or in the field. The instrument conforms to the ASTM D6595 Standard Test Method for Determination of Wear Metals and Contaminants in Used Lubricating Oils or Used Hydraulic Fluids by Rotating Disc Electrode Atomic Emission Spectrometry and ASTM D6728 Standard Test Method for Determination of Contaminants in Gas Turbine and Diesel Engine Fuel by Rotating Disc Electrode Atomic Emission Spectrometry.


The instrument can be widely used in fields of oil quality monitoring for large equipment, such as aircrafts, warships, high-speed railways, engineering machinery, and etc. It can be applied to the monitoring of mechanical wear and fault diagnosis analysis. It is commonly applied to the field of metallic elements analysis in oil.

2, Key parameters
•The instrument can be equipped with up to 8 high-performance CCD detector systems, 3648 pixels of each CCD.
•Dual-optical chamber system , the wavelength of short wavelength : 200nm-470nm, while the wavelength of long wavelength: 470-800nm diffraction grating
•High performance holographic diffraction grating, the Rowland circle grating has 2700 grating lines
.
•Focal length of Rowland circular optical chamber: 500mm.
•The maximum optical resolution is 0.006nm.
•The excitation voltage of the instrument is 14000-volt, the high-performance spark light source can be realized by bidirectional excitation.
•Both the Rowland circle and the main engine are equipped with constant temperature systems. These two constant temperature systems work together to remain the steady of the temperature.
•The main engine adopts hermetically sealed isolation cooling system, which can effectively prevent the invasion of dust and water mist.
•The design of the optical analytic software is based on the traditional industrial control habits, so it's easy to be used. Moreover, the instrument provides many different functions like automatic pixel calibration, work curve calibration, two-section work curve, reference line setting and automatic calculation the concentration, etc.
 
•The following table shows the testable element that conforms to ASTM D6595, and the other spectral line of elements can be added if needed.
•A disc electrode can accomplish five measurements. 


3, Elements can be tested:

 

Fe

Cu

Si

Mo

P

Sb

Al

Ag

Ti

V

Ba

Li

Mg

Ni

Pb

Cd

B

Na

Zn

Cr

Sn

Ca

Mn

K


4, Instrument specifications

•Size: L112xW50xH75 cm

•Weight:  125Kg

 

   5, Power supply

•       220V +/- 10%, one-phase

•       50/60 Hz, 1.0KVA