Welcome Customer !

Membership

KAYCAN INSTRUMENT (Dalian) Co.,Ltd
Free Member ·1YRS
,
Other

Main Products: 仪器仪表

Xwboo>Products
Product Categories

KAYCAN INSTRUMENT (Dalian) Co.,LtdFree·1YRS

  • E-mail

    jimmychou@kaycantest.com;info@kaycantest.com

  • Phone

    +86-411-86315116

  • Address

    DAXINZHAIZI village, Ganjingzi District, Dalian,Liaoning province China.

Contact Now

KN-5133 Gel Index Tester (LTLS)

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
KN-5133 Gel Index Tester (LTLS)
Product Details

凝胶 D5110-450.png

KN-5133 Gel Index Tester (LTLS)

Overview

  KN-5133 Gel Index Tester (LTLS) conforms to ASTM D5133 Standard Test Method for Low Temperature, Low Shear Rate, Viscosity/Temperature Dependence of Lubricating Oils Using a Temperature Scanning Technique. This test method covers the measurement of the apparent viscosity of engine oil at low temperatures and ASTM D7110 Standard Test Method for Determining the Viscosity-Temperature Relationship of Used and Soot-Containing Engine Oils at Low Temperature. This Test method covers how to measure the apparent viscosity of used and soot-containing engine oils at low temperature.


Features

1.        Metal bath cold well, no noise

2.        Microcomputer temperature controller, PID adjustment, PT100 temperature sensor with high precision

3.        One-button automatic lifting system, hydrometer automatic positioning

4.        Unique test tube lock device, it is able to fix the test tube stable

5.        Big touch screen operation

6.        Dedicated software, be able to correct the viscosity and analysis the linear accuracy

7.        Automatic calibration process, the calibration data will be shown in diagram

8.        Multiple temperature correction, also can add the correction point freely

9.        Automatic scan the viscosity and generate the gel curve. Will automatic analysis the gel index and temperature

10.    Adopts linear curve cooling, cooling rate could be edited


Technical Parameters

1.        Cooling mode: Semi-conductor analysis the linear accuracy

2.        Temperature control mode: Digital display PID temperature controller

3.        Temperature control range: Ambient~40±0.1℃

4.        Measuring range: 0~40000mPa·s

5.        Operation mode: Touch screen

6.        Lifting mode: Automatic

7.        Rated voltage: AC220V, 50Hz

8.        Total power: Main host: 800W,

9.                   Low temperature bath:1200W

10.    Dimension: Main host: 400*250*700mm,

Low temperature bath: 430*540*730mm

11.    Net weight: Main host: 32kg,

Low temperature bath: 45kg