KN-AAS Flame Furance Atomic Absorption Spectrophotometer

Model
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
KN-AAS Flame Furance Atomic Absorption Spectrophotometer
Product Details


AAS.flame.png


KN-AAS Flame Furnace Atomic Absorption Spectrophotometer

Overview

KN-AAS Flame Furnace Atomic Absorption Spectrophotometer conforms to ASTM D5863 Standard Test Methods for Determination of Nickel, Vanadium, Iron, and Sodium in Crude Oils and Residual Fuels by Flame Atomic Absorption Spectrometry. When fuels are combusted, metals present in the fuels can form low melting compounds that are corrosive to metal parts. Metals present at trace levels in petroleum can deactivate catalysts during processing. These test methods provide a means of quantitatively determining the concentrations of vanadium, nickel, iron, and sodium. Thus, these test methods can be used to aid in determining the quality and value of the crude oil and residual oil.

 

Features

1.      High precision automatic optical system

2.      Polymer spray chamber, Polymer materials corrosion spray chamber, acid and alkali resistance

3.      Titanium burner, the optional 50mm and 100mm burner

4.      Automatic analysis, It can automatically accomplish safety ignition, extinction and switching, Reliable structure, low fault rate, thus ensuring the sensitivity and reproducibility of the flame method. He light source system six lamp automatic conversion, can be directly used high performance hollow cathode lamp, improve the sensitivity analysis of the flame, the automatic adjustment of the power supply parameters and the beam position, automatic wavelength scanning and searching peak

 

Technical parameters

 Mainframe

Light Source: ≤3 lamps automatic turret, automatic alignment

Power Supply: 110/220V (+5% ~ -10%), 60/50Hz; 5000VA

Lamp Current: pulsed power supply

Optical System: large 1800 /mm grating ruling, full closed optical system

Wavelength Range: 190nm-900nm , Automatically peak find, a key optical optimization function

Wavelength Accuracy:≤0.15nm

Wavelength Repeatability:±0.1nm

Spectral Bandwidth: 0.1nm、0.2nm、0.4nm、1.0nm、2.0nm,(5 steps with automatic changeover)

Baseline Stability:≤±0.002A/30 min (Static), ≤±0.005A/30min (Dynamic)

Absorbance Range: 0-4A

Flame Analytical System

Detector: imported photomultiplier tube

Burner Head: full titanium combustion head, 50mm or 100mm general combustion head

Atomization Chamber: polymer explosion-proof spray chamber

Nebulizer : atomizer efficient glass atomizer, can also be customized

Ignition Type: microcomputer control, automatic ignition

Gas Control: automatic gas control system

Detection Limits(Cu): 0.002μg/mL

Precision: RSD≤0.5%