Model | YS6080(Pulsed xenon lamp) |
Optical Geometry | Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle); SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing); SCI (specular component included)/SCE (specular component excluded);Include UV / excluded UV light source; Haze(ASTM D1003); Conforms to CIE 5,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 |
|
|
Integrating Sphere Size | Φ 154mm |
Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp,420nm cut-off Xenon Lamp,460nm cut-off Xenon Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Pitch | 10nm |
Semiband Width | 5nm |
Reflectance Range | 0~200% |
Measuring Aperture | Reflective : Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; Transmissive : Φ25mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position |
|
Specular Component | Reflectance: SCI&SCE Transmittance: SCI&SCE |
|
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, APHA/Pt-Co Index, 555 Index, Haze(ASTM D1003),Saybolt,Color code (ASTM D1500) |
|
|
|
|
|
Observer Angle | 2° & 10° |
Illuminants | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30 |
Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.06% Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.012 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.06% Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) |
|
|
|
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles) |
|
Size | 370×300×200mm |
Weight | About 9.6kg |
Power Supply | DC 24V, 3A Power Adapter |
Light Source Device Life | 5 years, more than 3 million times measurements. |
Display | 7" TFT Capacitive Screen-touch Display |
Data Port | USB & Bluetooth & Print serial port |
Data Storage | Standard 5000 Pcs, Sample 40000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, (Optional Customized German, French and Spanish) |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Guide, CD Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4mm caliber, 15mm caliber, 8mm caliber, 4mm caliber,Transmissive Test Component,Micro Aperture(4mm) transmission test clamp component |
Optional Accessory | Micro-printer, Instrument inversion components,culture dish |
Notes: The specifications are subject to change without notice. |