YSI-ProDSS Multiparameter Digital Water Quality Meter

Model
Nature of the Manufacturer
Other
Product Category
Water Equipment
Place of Origin
City, Province
Overview
The YSI ProDSS (digital sampling system) is a portable water quality multiparameter instrument for the measurement of several critical parameters - dissolved oxygen (optical), total algae, turbidity, pH, ORP, conductivity, specific conductance, salinity, TDS, resistivity, TSS, ammonium, ammonia, chloride, nitrate, depth (optional), temperature and GPS coordinates.
Product Details

YSI-ProDSS

Multiparameter Digital Water Quality Meter


The YSI ProDSS (digital sampling system) handheld multiparameter meter provides extreme flexibility with two main cable options. Choose between the fully loaded 4-port cable assembly outfitted with any four DSS sensors (with depth or no depth) or the ODO/CT probe and cable - where you get accurate DO measurements every time with an optical dissolved oxygen sensor with an inline conductivity sensor, allowing for real-time salinity compensation.


ProDSS-英文内容.jpg


Features:

* Designed for use in applications such as surface water, groundwater, coastal/estuarine, aquaculture, and wastewater, the rugged and reliable ProDSS allows for the measurement of water quality parameters with digital sensors. The ProDSS water quality meter uses smart sensor technology that allows sensors to be automatically recognized by the handheld while retaining calibration data.

* An easy-to-read backlit color display, large memory capacity, simple calibration procedures, rechargeable battery and powerful data management program (KorDSS) all help to make your sampling experience more convenient.

* The optional GPS and depth along with a wide range of cables and sensors (sold separately) allows for complete customization of the ProDSS. Military spec connectors, IP-67 waterproof rating, rubber over-molded case and 1-meter drop tests ensures durability to provide years of sampling even in the harshest field conditions.

Parameters Available:
Dissolved Oxygen (optical) ,Turbidity ,New! - Total Algae-Phycocyanin, New! - Total Algae-Phycoerythrin ,pH ORP/Redox, Conductivity ,Specific Conductance ,Salinity ,Total Dissolved Solids (TDS) ,Resistivity ,Seawater Density, Total Suspended Solids (TSS) ,Depth ,GPS Coordinates Ammonium ,Ammonia, Chloride Nitrate ,Temperature Barometric ,Pressure
There are multiple features of the ProDSS water quality meter:
* Single cable design with lengths up to 100 meters
* User-replaceable cables provide versatility, reduce down time and reduce overall cost of ownership
* 4 port cables feature user-replaceable sensors; universal ports can accept any 4 sensors; optional depth sensor available (with depth and no depth)
* ODO/CT probe and cable assemblies feature integral (built-in) optical DO and conductivity sensors; rugged ODO sensor cap with 2-year warranty is pre-installed on new assemblies; kits with an ODO/CT assembly and a ProDSS handheld are available
* Long-life rechargeable lithium-ion battery to power handheld and sensors
* Color display and backlit keypad; menu-driven operation * Digital smart sensors are automatically recognized by the instrument and store calibration data
* Large memory (>100,000 data sets) with extensive site list and Data ID tag capabilities
* KorDSS software (included) and USB on-the-go connector assist with data management
* Global positioning system (GPS) (optional)
* Rugged, waterproof case (IP-67 rated) with rubber over-mold and metal, military-spec (MS) cable connectors as well as rugged titanium sensors
* Multiple languages: English, Spanish, Portuguese, French, German, Italian, Japanese, Norwegian, Chinese (simplified and traditional), Korean, and Thai


ProDSS-英文内容2.jpg


ProDSS-英文内容3.jpg

Benchtop
Yes, optical BOD probe for the lab is available
Buffer RecognitionYes, auto-buffer recognition for USA (4.00, 7.00, 10.00) and NIST (4.01, 6.86, 9.18) buffer sets. Calibration values are
automatically compensated for temperature for both buffer sets.
CertificationsFCC, WEEE, UN Part III Section 38.3 test methods for lithium-ion batteries (class 9), RoHS, Assembled in USA, IP-67, 1-meter drop
test, CE
Connectivity / CommunicationsBuilt-in micro USB On-The-Go port for PC connection, recharging/powering the ProDSS and connecting directly to a USB stick
ConnectorMS (military spec) waterproof with quarter-turn bayonet lock (unsurpassed in regards to durability)
Data ManagementKorDSS desktop PC software (included), >100,000 data sets
Desktop Software CompatibleKorDSS desktop PC software (included)
Digital / Digital SensorsYes
Flow CellYes, flow cell is available
GLP Compliancedetailed GLP information is stored and is available to view, download or print, Yes
GPScoordinates are stored with measurement data and site lists, Optional internal GPS
Graphic DisplayColor, LCD graphic display, backlit keypad
LanguagesItalian, German, Norwegian, English, French, Portuguese, Japanese, Chinese (Simplified & Traditional), Spanish
Logging CapabilitiesSingle point or Continuous, Yes
Measurement Method / ChannelsDigital
Memory>100,000 data sets, 400 GLP files
MultiparameterYes
Operating Temperature0 to 50C (32 to 122F)
Parameters MeasuredDissolved Oxygen (%), Dissolved Oxygen (mg/L), Temperature, Turbidity, Conductivity, Specific Conductance, Resistivity, Salinity,
Water Density, pH, ORP, Ammonium, Nitrate, Chloride, Total Dissolved Solids (TDS), Total Suspended Solids (TSS), Depth, Barometer
PowerRechargeable lithium-ion battery pack providing ~48 hours of battery life (instrument only with backlight off)
SamplingYes
Security / Password Protection / UserIDYes
SizeInstrument: 8.3 cm width x 21.6 cm length x 5.6 cm depth (3.27 in x 8.5 in x 2.21 in)
Bulkhead with sensors, without depth (no guard): 33.3 cm (13.11 in) length - the length with the ISE sensors is 34.04 cm (13.4 in)
Bulkhead with sensors, with depth (no guard): 35.84 cm (14.11 in) length - the length with the ISE sensors is 36.58 cm (14.4 in)
Bulkhead with guard, without depth: 42.82 cm (16.86 in) length and 4.75 cm (1.87 in) outer diameter
Bulkhead with guard, with depth: 45.36 cm (17.86 in) length and 4.75 cm (1.87 in) outer diameter
Smart Sensors / Ports4 universal sensor ports on each cable, can accept any ProDSS sensor, Yes
Storage Temperature0 to 45C (32 to 113F) with battery installed0 to 60C (32 to 140F) without battery installed
User CalibratableYes
User ReplaceableYes
Warranty3-year instrument; 2-year bulkhead, cable assembly, and sensors; 1-year pH and pH/ORP sensor modules, ODO (opticalDO) sensor caps,
and Li-Ion battery pack; 6-months ammonium, nitrate, and chloride sensor modules
Waterproof
floats, IP-67 (even with the battery cover off)

ProDSS System Specifications (Instrument, Cables & Sensors):

Parameter(units)
Sensor TypeRangeAccuracyResolutionCalibrationMaximumDepth
Dissolved Oxygen
(% saturation)
Optical Luminescence - Lifetime Method0 to 500%0 to 200% (±1% of reading or 1% air saturation, whichever is greater)
200% to 500% (±8% of reading)
0.1% or 1% air saturation (user selectable)1 or 2 points100 m
Dissolved Oxygen (mg/L, ppm)
temp comp range -5 to 50°C
Optical Luminescence - Lifetime Method0 to 50 mg/L0 to 20 mg/L
(±0.1 mg/L or 1% of reading, whichever is greater)
20 – 50 mg/L (±8% of reading)
0.1 or 0.01 mg/L (user selectable)1 or 2 points (user selectable)100 m
Temperature
(°C, °F, K)
Thermistor; Combination Sensor with Conductivity-5 to 70°C (23 to 158°F)±0.2°C0.1°C or 0.1°F (user selectable)None100 m
Turbidity
(FNU, NTU)
Nephelometric - Optical, 90° Scatter0 to 4000 FNU0 to 999 (0.3 or ±2% of reading, whichever is greater)
1000 to 4000 (±5% of reading)
0.1 FNU1, 2, or 3 points (user selectable)-
Conductivity*
(µS, mS)
Four Nickel Electrode Cell0 to 200 mS/cm0 to 100 mS/cm (±0.5% of reading or 0.001 mS/cm, whichever is greater)
100 to 200 mS/cm (±1% of reading)
0.001, 0.01 or 0.1 mS/cm (range dependent)1 point100 m
Specific Conductance
(µS, mS)
Calculated from Conductivity and Temperature0 to 200 mS/cm±0.5% of reading or 0.001 mS/cm, whichever is greater0.001, 0.01, 0.1 mS/cm1 point-
Resistivity
(ohm-cm, kohm-cm, Mohm-cm)
Calculated from Conductivity and Temperature0 to 2 Mohms±0.1% Full Scale0.001, 0.01, 0.1 ohms--
Salinity
(ppt, PSU)
Calculated from Conductivity and Temperature0 to 70 ppt±1.0% of reading or ±0.1 ppt, whichever is greater0.01 ppt1 point-
Water Density
(Sigma, Sigma T)
Sigma is Calculated from Salinity, Temperature, and Pressure
Sigma T is Calculated from Salinity and Temperature
0.0 to 50.0 sigma, sigma T-0.1 sigma or sigma T--
pH
(mV, pH units)
Glass Bulb Combination Electrode; Ag/AgCl Reference Gel0 to 14 units±0.2 units0.01 units1, 2, or 3 points (user selectable)100 m
ORP
(mV)
Platinum Button; Ag/AgCl Reference--1999 to +1999 mV±20 mV0.1 mV1 point100 m
Ammonium**
(NH4-N mg/L, NH4-N mV)
ammonia with pH sensor
Ion Selective Electrode0 to 200 mg/L NH4-N±10% of reading or 2 mg/L, whichever is greater0.01 mg/L1, 2, or 3 point
(user selectable)
20 m
Ammonia***
(NH3-N mg/L)
Calculated from Ammonium, Temperature, Salinity and pH0 to 200 mg/L NH4-N-0.01 mg/L--
Nitrate**
(NO3-N mg/L, NO3-N mV)
Ion Selective Electrode0 to 200 mg/L NO3-N±10% of reading or 2 mg/L, whichever is greater0.01 mg/L1, 2, or 3 point
(user selectable)
20 m
Chloride**Ion Selective Electrode0 to 18000 mg/L Cl±15% of reading or 5 mg/L, whichever is greater0.01 mg/L1, 2, or 3 point
(user selectable)
20 m
Total Dissolved Solids (TDS)
(mg/L, kg/L, g/L)
Calculated from Conductivity and Temperature0 to 100 g/LUser-Selectable TDS Multiplier (0.30 to 1.00; 0.65 default)0.001, 0.01, 0.1g/L--
Total Suspended Solids (TSS)
(mg/L)
Correlated from Turbidity Field Measurements and Lab TSS Measurements from Grab Samples0 to 30000 mg/LCalculated from Turbidity and User-Entered Correlation Points0.01, 0.1 mg/L--
Chlorophyll
(RFU or µg/L chl)
Optical Luminescence0 to 100 RFU or 0 to 400 µg/L chlLinearity: r2 ≥ 0.999 for Rhodamine WT across full range0.01 RFU or 0.01 µg/L chl2 point-
Phycocyanin
(RFU or µg/L PC)
Optical Luminescence0 to 100 RFU or 0 to 100 µg/L PCLinearity: r2 ≥ 0.999 for Rhodamine WT across full range0.01 RFU or 0.01 µg/L PC2 point-
Phycoerythrin
(RFU or µg/L PE)
Optical Luminescence0 to 100 RFU or 0 to 280 µg/L PELinearity: r2 ≥ 0.999 for Rhodamine WT across full range0.01 RFU or 0.01 µg/L PE2 point-
Depth
(m, ft)
Pressure Transducer0 to 100 m (0 to 328 ft)±0.004 m (±0.013 ft) for 1, 4 and 10-m cables
±0.04 m (±0.13 ft) for cables 20-m and longer
0.001 m or 0.01 ft1 point-
Barometer
(mmHg, inHg, mbar, psi, kPa, ATM)
Piezoresistive375 to 825 mmHg
±1.5 mmHg from 0 to 50°C
0.1 mmHg1 point-
Similar Product Recommend