Welcome Customer !

Membership

Shanghai TOW Intelligent Technology Co., Ltd.
Free Member ·1YRS
,
Other

Main Products: 动物实验设备

Xwboo>Products

Handheld Animal Monitor

Model
Nature of the Manufacturer
Other
Product Category
en小动物
Place of Origin
City, Province
Overview
Handheld Animal Monitor
Product Details

Features

1. 5 - inch LED screen (touch screen), NIBP (blood pressure), SPO2 (blood oxygen), TEMP (body temperature) /EtCO2 ( end-tidal carbon dioxide ) (one of them can be selected)

2. It can be flexibly configured with NIBP/SPO2/WIFI/base , desktop, hand-held, bracket, and flexible assembly methods, which can meet various clinical environments

3. Capacitive touch screen, shortcut keys, and random operation

4. High - resolution LED screen, stable user interface style, highlighting professional equipment

5. The blood oxygen weak perfusion performance can reach 0.05%, which can meet the blood oxygen saturation measurement in various environments

6. The battery can work for up to 15 hours

 

technical parameter

model

VSM 50

Display parameters

5 inch LED touch screen , high resolution LED

Package Size

320*220*90mm

weight

1.5KG

SpO2

SpO2 measurement range

0% to 99%

SpO2 measurement accuracy

The error is ±2% within the range of 70% to 99%, other ranges are undefined

SpO2 alarm range

Consistent with the display range, the step length of the alarm limit setting is 1%

Pulse rate measurement range

20bpm ~ 254bpm

Pulse rate alarm range

Consistent with the display range, the step length of the alarm limit setting is 1bpm

Pulse rate measurement accuracy

±3 bpm

Average SpO2 pulse rate

8 seconds

wavelength range

500nm ~ 1000nm for all sensors

maximum luminous power

150 mW for all sensors

perfusion index

0.015%

operating mode

Manual, automatic, continuous

measurement accuracy

The maximum average error is ±5 mmHg (±0.67 kPa), and the maximum standard deviation is 8 mmHg (1.067 kPa), whichever is greater in absolute value.

Alarm delay time

<10s

Cuff pressure range

Cat: 0 mmHg to 210 mmHg (0 kPa to 28.0 kPa)

Dog: 0 mmHg to 300 mmHg (0 kPa to 40.0 kPa)

Horse: 0 mmHg~300 mmHg (0 kPa~40.0kPa)

NIBP

Measurement methods

Oscillation

Measurement parameters

Systolic, diastolic, mean arterial pressure

operating mode

Manual, automatic, continuous

systolic blood pressure range

Cat: 30 mmHg ~ 145mmHg (4.0kPa ~ 19.3kPa)

Dog: 30 mmHg ~ 230mmHg (4.0kPa ~ 30.7kPa)

Horse: 30 mmHg ~ 280mmHg (4.0kPa ~ 37.3kPa)

Diastolic range

Cat: 10mmHg ~ 105mmHg (1.3kPa ~14.0kPa)

Dog: 10 mmHg to 220 mmHg (1.3 kPa to 29.3 kPa)

Horse: 10mmHg ~ 100mmHg (1.3kPa ~ 13.3kPa)

Average pressure range

Cat: 10 mmHg ~ 115mmHg (1.3kPa ~ 15.3kPa)

Dog: 10 mmHg~175mmHg (1.3kPa~23.3kPa)

Horse: 10mmHg ~ 240mmHg (1.3kPa ~ 32.0kPa)

measurement accuracy

The maximum average error is ±5 mmHg (±0.67 kPa), and the maximum standard deviation is 8 mmHg (1.067 kPa), whichever is greater in absolute value.

Alarm range

Consistent with the display range, the alarm limit setting step length is 1mmHg or

0.1kPa

TEMP

TEMP measurement range

0℃~50.0℃ (32.0℉~122.0℉)

TEMP measurement accuracy

±0.1℃

Alarm setting range

Consistent with the display range, the step length of the alarm limit setting is 0.1°C

Alarm delay time

<10s

Minimum time to display correct TEMP reading

10 seconds

update time

about 1 second

CO 2

Operating mode

Measurement mode, standby mode

Measuring range

0mmHg~150mmHg(0kPa~19.95kPa)

precision

Within the range of 0 mmHg~40 mmHg (0 kPa~5.33 kPa), the error is ±2 mmHg (±0.3 kPa);

Within the range of 41 mmHg~100mmHg (5.47 kPa~ 13.3 kPa), the error is ±5 mmHg (±0.7 kPa);

Within the range of 101 mmHg~150 mmHg ( 13.5 kPa~19.95 kPa), the error is ±8 mmHg (±1.1 kPa)

Alarm setting range

0 mmHg ~ 150 mmHg (0 mmHg ~ 19.95 kPa),

Alarm limit setting in steps of 1 mmHg or 0.1 kPa

Alarm delay time

<10s

Waveform sweep speed

6.25mm/s, 12.5mm/s

Response time

System delay when concentration changes: <1s

Waveform rise time: 0.15s

 

configuration list:

Standard

Blood oxygen, non-invasive blood pressure, body temperature for animals

Accessories: Animal Y-type blood oxygen probe (3 meters), blood pressure extension tube (2 meters), animal blood pressure cuff No. 2 and No. 3

Power adapter, charging cable 2 meters, charging base

Optional

WIFI, two microcode scanning, mainstream CO2 (UGS20) , body cavity probe

1

Repetitive SpO2 probe Y200 Y200-300183G-5(V)

2

Blood pressure extension tube reusable 2 meters

3

Veterinary Blood Pressure Cuff No. 1

4

Veterinary Blood Pressure Cuff No. 2

5

Veterinary blood pressure cuff size 3

6

Veterinary blood pressure cuff size 4

7

Veterinary blood pressure cuff size 5

8

EP29 US adapter 5V 2A USB white

9

Charging data cable type-c 5A

10

8-core dual-slot 2.25K body cavity temperature probe

11

Mainstream CO2 Modules

12

Handheld product base


Similar Product Recommend