Features
1. 5 - inch LED screen (touch screen), NIBP (blood pressure), SPO2 (blood oxygen), TEMP (body temperature) /EtCO2 ( end-tidal carbon dioxide ) (one of them can be selected)
2. It can be flexibly configured with NIBP/SPO2/WIFI/base , desktop, hand-held, bracket, and flexible assembly methods, which can meet various clinical environments
3. Capacitive touch screen, shortcut keys, and random operation
4. High - resolution LED screen, stable user interface style, highlighting professional equipment
5. The blood oxygen weak perfusion performance can reach 0.05%, which can meet the blood oxygen saturation measurement in various environments
6. The battery can work for up to 15 hours
technical parameter
model | VSM 50 |
Display parameters | 5 inch LED touch screen , high resolution LED |
Package Size | 320*220*90mm |
weight | 1.5KG |
SpO2 | |
SpO2 measurement range | 0% to 99% |
SpO2 measurement accuracy | The error is ±2% within the range of 70% to 99%, other ranges are undefined |
SpO2 alarm range | Consistent with the display range, the step length of the alarm limit setting is 1% |
Pulse rate measurement range | 20bpm ~ 254bpm |
Pulse rate alarm range | Consistent with the display range, the step length of the alarm limit setting is 1bpm |
Pulse rate measurement accuracy | ±3 bpm |
Average SpO2 pulse rate | 8 seconds |
wavelength range | 500nm ~ 1000nm for all sensors |
maximum luminous power | 150 mW for all sensors |
perfusion index | 0.015% |
operating mode | Manual, automatic, continuous |
measurement accuracy | The maximum average error is ±5 mmHg (±0.67 kPa), and the maximum standard deviation is 8 mmHg (1.067 kPa), whichever is greater in absolute value. |
Alarm delay time | <10s |
Cuff pressure range | Cat: 0 mmHg to 210 mmHg (0 kPa to 28.0 kPa) Dog: 0 mmHg to 300 mmHg (0 kPa to 40.0 kPa) Horse: 0 mmHg~300 mmHg (0 kPa~40.0kPa) |
NIBP | |
Measurement methods | Oscillation |
Measurement parameters | Systolic, diastolic, mean arterial pressure |
operating mode | Manual, automatic, continuous |
systolic blood pressure range | Cat: 30 mmHg ~ 145mmHg (4.0kPa ~ 19.3kPa) Dog: 30 mmHg ~ 230mmHg (4.0kPa ~ 30.7kPa) Horse: 30 mmHg ~ 280mmHg (4.0kPa ~ 37.3kPa) |
Diastolic range | Cat: 10mmHg ~ 105mmHg (1.3kPa ~14.0kPa) Dog: 10 mmHg to 220 mmHg (1.3 kPa to 29.3 kPa) Horse: 10mmHg ~ 100mmHg (1.3kPa ~ 13.3kPa) |
Average pressure range | Cat: 10 mmHg ~ 115mmHg (1.3kPa ~ 15.3kPa) Dog: 10 mmHg~175mmHg (1.3kPa~23.3kPa) Horse: 10mmHg ~ 240mmHg (1.3kPa ~ 32.0kPa) |
measurement accuracy | The maximum average error is ±5 mmHg (±0.67 kPa), and the maximum standard deviation is 8 mmHg (1.067 kPa), whichever is greater in absolute value. |
Alarm range | Consistent with the display range, the alarm limit setting step length is 1mmHg or 0.1kPa |
TEMP | |
TEMP measurement range | 0℃~50.0℃ (32.0℉~122.0℉) |
TEMP measurement accuracy | ±0.1℃ |
Alarm setting range | Consistent with the display range, the step length of the alarm limit setting is 0.1°C |
Alarm delay time | <10s |
Minimum time to display correct TEMP reading | 10 seconds |
update time | about 1 second |
CO 2 | |
Operating mode | Measurement mode, standby mode |
Measuring range | 0mmHg~150mmHg(0kPa~19.95kPa) |
precision | Within the range of 0 mmHg~40 mmHg (0 kPa~5.33 kPa), the error is ±2 mmHg (±0.3 kPa); Within the range of 41 mmHg~100mmHg (5.47 kPa~ 13.3 kPa), the error is ±5 mmHg (±0.7 kPa); Within the range of 101 mmHg~150 mmHg ( 13.5 kPa~19.95 kPa), the error is ±8 mmHg (±1.1 kPa) |
Alarm setting range | 0 mmHg ~ 150 mmHg (0 mmHg ~ 19.95 kPa), Alarm limit setting in steps of 1 mmHg or 0.1 kPa |
Alarm delay time | <10s |
Waveform sweep speed | 6.25mm/s, 12.5mm/s |
Response time | System delay when concentration changes: <1s Waveform rise time: 0.15s |
configuration list:
Standard | Blood oxygen, non-invasive blood pressure, body temperature for animals |
Accessories: Animal Y-type blood oxygen probe (3 meters), blood pressure extension tube (2 meters), animal blood pressure cuff No. 2 and No. 3 | |
Power adapter, charging cable 2 meters, charging base | |
Optional | WIFI, two microcode scanning, mainstream CO2 (UGS20) , body cavity probe |
1 | Repetitive SpO2 probe Y200 Y200-300183G-5(V) |
2 | Blood pressure extension tube reusable 2 meters |
3 | Veterinary Blood Pressure Cuff No. 1 |
4 | Veterinary Blood Pressure Cuff No. 2 |
5 | Veterinary blood pressure cuff size 3 |
6 | Veterinary blood pressure cuff size 4 |
7 | Veterinary blood pressure cuff size 5 |
8 | EP29 US adapter 5V 2A USB white |
9 | Charging data cable type-c 5A |
10 | 8-core dual-slot 2.25K body cavity temperature probe |
11 | Mainstream CO2 Modules |
12 | Handheld product base |