FNN-3200 Plane Electronic Compass
FNN-3200 Plane Electronic Compass
1 .Product Features
(1)Through two-axis magnetoresistive sensor measures plane Earth's magnetic field, and translates the measurements into heading information.
(2)High-speed and high-precision A / D conversion. The accuracy of magnetic field measurement is 100μGuass.
(3)Embedded microprocessors calculate the angle between sensor and Magnetic North.
(4)Operating temperature is -40℃to+85℃. Storage temperature is -55℃to+100℃.
2. Main Parameters (RT test):
Characteristic | Condition | Min | Typical | Max | unit |
Supply voltage | Direct-current | 4.5 | 5 | 5.5 | V |
Working current | Supply voltage = 5V | 30 | 35 | 40 | mA |
Settling Time |
|
| 5 |
| sec |
Field range | Ambient magnetic field environment | -2 |
| 2 | Gauss |
Accuracy | After user calibration |
| ±1 |
| º |
Resolution |
|
| ±0.2 |
| º |
Linear |
|
| ±0.7 | ±1 | % |
Repeatability |
|
| ±0.4 |
| º |
stability | Interval 24 hours |
| ±0.6 |
| º |
Thermal zero drift | Temperature range: -40 ℃ -85 ℃ |
| ±0.04 | ±0.06 | º/℃ |
Maximum magnetic interference+1 |
|
|
| 20 | Gauss |
Data update rate | Output continuous output |
| 3 |
| Hz |
Baud Rate | RS232、RS485、TTL |
| 9600 |
| Baud |
Communication parameters | RS232、RS485、TTL | 9600,n,8,1 |
|
storage temperature | Ambient temperature | -50 |
| 90 | ℃ |
Operating temperature | Ambient temperature | -40 |
| 80 | ℃ |
weight | Uncased(PCB50)*2 | 10 | 12 | 14 | g |
Uncased(PCB35)*2 | 4 | 6 | 8 | g |
size | Uncased(PCB50)*2 | Diameter: 50 Height: 18 | mm |
Uncased(PCB35)*2 | Diameter: 50 Height: 16 | mm |
Download:
FNN-3200.pdf