| Physical Features |
| Dimension(W×H×D) | 196.5×80×62mm |
| Power consumption | 11W |
| Program memory | 128K+64K+64K |
| Data memory | 64KB+100KB,Data permanent stored |
| Maximum number of expansion modules | 7 |
| Maximum digital | 128DI/128DO(expand CAN expansion board up to 640DI/640DO) |
| Maximum analog | 32AI/32AQ(expand CAN expansion board up to 194AI/194AO) |
| Data stored | FlashROM Data permanent stored |
| Power supply features |
| Rated input voltage | AC220V |
| Impulse current | 264VAC,20A |
| Isolation (field and logic) | 1500VAC |
| Hold time (power off) | 20ms/80ms above,120/240VAC |
| Sensor +24V power output | Voltage range:20.4~28.8VDC |
| Rated current:300mA |
| Maximum ripple noise (<10MHz) :<1V peak-to-peak value |
| Isolation (sensor and logic):None |
| Power alarm | when it is lower than 15V, the alarm bit SM195.1 |
| Regular features |
| Total timers | 512 |
| 1ms | 4 |
| 10ms | 272 |
| 100ms | 236 |
| Counters | 256 |
| Accumulators | 4 |
| Memory bit | 256bit |
| Local storage(L) | 64 bytes independent |
| Sequence control relay(S) | 256 bit |
| Time interrupt | 2*1ms resolutions |
| Edge breaks | 8 |
| Boolean operation execution time | ≤0.15us |
| Floating operation execution time | ≤6.2us |
| Real time clock | Built-in |
| BD expansion board port | One ,BD expansion board supports RS485 expansion board, CAN expansion board, and analog expansion board |
| System indicator | SF indicator (red) | ON:Program error,OFF:Normal |
| DIAG indicator (orange) | ON:Program control,OFF:Normal |
| RUN indicator (green) | ON:running,OFF:stopped |
| STOP indicator (orange) | ON:stopped,OFF:running |
| RMC indicator (green) | ON:remote control is connected,OFF:remote control is disconnected |
| LNK/ACT indicator (green) | ON:Ethernet connection,Blinking: Transmission is underway,OFF:disconnect |
| Run switch | RUN/STOP |
| External battery port | 1、Special battery card; 2. Professional battery holder (CR1220) supports either external battery |
| Programming card | Support |
| Integrated communication capabilities (PPI/ free port) |
| Communication interface | 2 Communication port: PORT0:PPI/free port,standard RS485 PORT1:PPI/free port,standard RS485 After the RS485 expansion board is plugged in and restarted, PORT0 (RS485, PPI communication port) PORT1 (RS485, PPI/ free port), FPORT0 (free port) |
| Baud rate(baud) | 9.6k、19.2k and 187.5k |
| Free port baud rate(baud) | 1.2k ~ 115.2k |
| Maximum number of stations | 32 stations per segment, 126 stations per network |
| Maximum number of main stations | 32 |
| Point-to-point (PPI master mode) | Yes(NETR/NETW),With a maximum of 8 connections and a maximum communication of 200 bytes per connection |
| MPI connect | 8(1PG/1OP),2 reserved |
Maximum cable length per section Use an isolated repeater No isolated repeater is used | The baud rate is 1000 m at 187.5 K and 1200 m at 38.4 K 50m |
|
|
| Ethernet Communication |
| Communication port | 1 Standard Ethernet port |
| Communication standards | IEEE802.3 standards |
| Transmission speed | 10Mbps/100Mbps adaptive |
| Adaptive cross-connect | Support |
| Hardware interface | RJ45 |
| Protocol Type | UDP/TCP protocol Supports UDP_PPI, MODBUS_TCP, Socket, and S7 protocols, Ethernet communication between PLCS, and MiCo Ethernet programming. |
| Configuration mode | Ethernet port search PLC,support the mouth download system configuration. |
| Maximum number of connections | 8 UDP/PPI connections, no master or slave |
| 8 TCP/Modbus connections, no master or slave |
| 4 Socket connections, 2 UDP, 2 TCP |
| 8 S7 protocol, no master and slave, COTRUST PLC only as slave station |
| Maximum single data transmission | Up to 200 bytes for UDP_PPI transmission. |
| Up to 240 bytes are used for ModBus_TCP transmission. |
| Up to 512 bytes is used for Socket transmission |
| Up to 200 bytes for S7 transmission |
| Startup time of network port | 5 to 10 seconds. The startup time varies depending on the network environment. |
| Indicator | RMC | On: The remote server is successfully connected |
| Off: The remote connection is disconnected or the remote function is disabled |
| LINK/ACT | On: The hardware of the network port is connected |
| Blinking: Data is being exchanged |
| Off: The hardware of the network port is disconnected |
| The length of the communication cable | 100M,cable type is CAT5e or above |
| Isolation | Communication isolation |
| IP address reset function | Five consecutive times within two seconds |
| Upgrade Firmware function | Use MagicWorks PLC and MiCo to remotely upgrade firmware from company servers over Ethernet |
| I/O Features |
| Number of integrated digital inputs | 24 |
| Input type | Leak/Source |
| Number of integrated digital outputs | 16 |
| Output type | Source |
| Maximum digital | 128DI/128DO(expand CAN expansion board up to 640DI/640DO) |
| Maximum analog | 32AI/32AQ(expand CAN expansion board up to 194AI/194AQ) |
| The maximum number of local expansion IO modules | 7 |
| Pulse capture input | 14 |
| High-speed counters | Total
Uniphase counters AB-phase counters | 6 6×50KHz 4×30KHz |
|
|
Integrated Communication Function (CANopen) - use for CAN communication board model CTH2-CAN-01S2-EB |
| Communication Interface | 1(8 Pin) |
| Communication speed(kbps) | 1000 | 800 | 500 | 250 | 150 | 50 | 20 |
| Maximum cable length(m) | 25 | 50 | 100 | 250 | 500 | 1000 | 2500 |
| Maximum station address | 127 |
| Station address range | 1-127 |
| Maximum number of master and slave stations | 32 |
| Configuration method | CAN configuration blocks and EDS files |
| Maximum digital access | Nomal IO | CANopen IO |
| Byte | Memory starting address |
| Byte | Memory starting address |
| Input | 16 | IB0 | Input | 64 | IB16 |
| Output | 16 | QB0 | Output | 64 | QB16 |
| Maximum analog access | Normal IO | CANopen IO |
| Channel | Memory starting address |
| Channel | Memory starting address |
| Input | 32 | AIW0 | Input | 162 | AIW64 |
| Output | 32 | AQW0 | Output | 162 | AQW64 |
| Integrated Communication Function (CANFree) - Used when extending the CAN communication board |
| Communication Protocol | CanFree |
| Use method | Supported by internal library instructions |
| Digital input features |
| Number of interated digital input | 24 |
| Input type | Leak/source |
| Rated voltage | 24 VDC |
| Maximum continuous allowable voltage | 30 VDC |
| Logic 1 signal (min.) | 18 VDC,3.0mA |
| Logical 0 signal (Max.) | 5 VDC,1mA |
Isolation (field and logic) Isolation group | 500 VAC,1min |
| Simultaneously connected input | 24 |
| Maximum cable length | 500m |
| Shielding: 50 m (high speed counter input); Unshielded: 300 meters (standard input) |
| Digital Output Features |
| Number of integrated digital output | 16 |
| Output type | Relays, dry contacts |
| Output frequency (maximum) | 100KHz(Q0.0-Q0.2),1KHz(Q0.3-Q1.7) |
| Rated voltage output | 24VDC,or 110V/220VAC |
| Output voltage range | 5-30VDC or 5-250VAC |
| Rated current per point | 2A |
| Rated current for each common point | 8A |
| Surge current | 7A,100ms |
| Lamp load (maximum) | 30W DC/200W AC |
| On resistance (contact) | 0.2Ω |
Contact life (rated load) | 100,000 times on and off |
|
| Output of simultaneously connected | 10 |
| Parallel output | None |
| Maximum cable length | Shielde | 500m |
| Unshielded | 150m
|