Physical Features CTH2 216-2AX35-0X40 |
Dimension(W×H×D) | 196.5×80×62mm |
Power dissipation | 11W |
Memory Features |
Program memory | 24KB+48KB |
Data memory | 10KB+100KB |
General Features |
Timers total 1ms 10ms 100ms | 512 4 272 236 |
Counters total | 256 |
Internal memory bits | 256 |
Stored permanently on power down | Data permanent stored |
Sequential control relay (S) | 256 |
Time Interrupts | 2*1ms resolution |
Edge Interrupts | 4 rising edges and/ or 4 falling edges |
Analog adjustment | Non |
Boolean execution speed | ≤0.15µs |
Float execution speed | ≤8µs |
Clock | embedded ,precision ±120s/m |
BD expansion board interface number | 1,Support CAN expansion board, analog expansion board |
System indicator | 5,STOP、RUN、SF、RMC、LINK/ACT |
RUN/STOP dial code | Yes,2 |
Battery card interface | Support,power supply below 2V,alarm bit SM195.0 |
Programming card and Memory card | Support |
Rated input voltage | 24VDC |
Power supply Native and extended bus+5V +24V | 660mA 200mA |
Integrated Communication Function |
Communication Interface | 2 communication ports ,PORT0:PPI/Free port,RS485;FPORT0:PPI/Free port,RS485
After plugging in the RS485 expansion board and restarting, PORT0 (RS485, PPI communication port) PORT1 (RS485, PPI/ free communication port), FPORT0 (free port) |
PPI baud rates(baud) | 9.6k、19.2k and 187.5k |
Freeport baud rates(baud) | 1.2k ~ 115.2k |
Maximum cable length Isolated repeater applied Isolated repeater unapplied | When it is 1000 m, baud rate is 187.5k; when it is 1200 m, 38.4k. 50m |
Maximum number of stations | 32 stations per segment,126 stations per network |
Maximum number of masters | 32 |
Point-to-point (PPI master station mode) | Yes(NETR/NETW), maximum 8 connections, and each connection has a maximum communication of 200 bytes |
MPI communication | (1PG/1OP) 8 in total, 2 reserved |
Ethernet Function |
Communication port | 1 Ethernet port |
Communication standard | IEEE802.3 standard |
Communication speed | 10Mbps and 100Mbps self-adaption |
Adaptive cross connection | Non support |
Interface to industrial Ethernet(10/100Mbps) | RJ45 port |
Protocol type | UDP/TCP protocol Support PDP_PPI, MODBUS_TCP, Socket, S7 protocols, support PLC Ethernet communication, support MiCo Ethernet programming. |
Collocation method | Support the upper computer through the Ethernet port search PLC, support the mouth download system configuration. |
Application interface | Support MiCo service, UDP_PPI, Modbus_TCP, S7 protocol, Socket programming.Support Ethernet port online firmware upgrade function. |
Maximum number of connections | 8 UDP_PPI, no master or slave 8 Modbus_TCP, no master or slave 4 Socket connections, 2 UDP, 2 TCP 8 S7 protocol, no master and slave, COTRUST PLC only as slave station |
User data number | Up to 200 bytes for UDP_PPI transmission. Up to 240 bytes are used for ModBus_TCP transmission. A maximum of 512 bytes is used for Socket transmission Up to 200 bytes for S7 transmission |
Port | local:1~65535 remote server:8888 |
Boot time or restart time after reset | 3 seconds |
Indicator lamp | Green RMC indicator: on: remote control in effect, off: remote control out
Green Ethernet indicator: on: connection, flicker: transmission; out: not connected |
Maximum cable length | 100m |
Isolation | Communication port isolation |