Parameters:
Types of control: straight acting operation |
Applicable medium: coal gas, natural gas, liquefied petroleum gas, etc. No corrosive gas |
Which gives: diaphragm seal seat valve |
Maximum working pressure: 0.2 MPa |
Nominal pressure: PN16 |
Connection mode: thread interface, interface flange (1-12) (optional) |
The power supply voltage: AC220V / 50 hzdc24v (optional) |
Closing time: < 1 seconds (about 20 milliseconds) |
Open mode: manual reset type |
Enclosure protection grade: IP54 |
Adaptive temperature :-10℃~ +60℃ |
Sealing material: special NBR/FKM rubber |
Voltage tolerance :-15% ~ +10% |
Body material: die-casting alloy aluminum |
Operating factor: pulse type |
Explosion proof grade :ExmbIIT4 |
Metal internals: stainless steel and brass |
Electrical connections: plugin (regardless of is the cathode) |
Specifications:

Structure:

Installation requirements:
Read the product manual carefully before installation and related technical information
Valve installed unit shall have corresponding qualifications and according to the relevant gas pipeline construction specifications required to install, explosion-proof electrical specifications and manufacturers.
Specification for emergency cut-off valve should be set before the manual shut-off valve.
Should be in accordance with the requirements of the position of the graphic and body mark the airflow direction of installation.
Should be to pipe purging after clean, then install the solenoid valve, so as not to purge tube material damage to the sealing in the valve material, air tightness.
The valve should be carefully check prior to power connection, it is forbidden to wrong wiring. Add wrong voltage, so as not to damage the solenoid valve.
On pipeline leakage testing, must first open the valve.
Valve installed in the outdoor, rain, snow cover should form a complete set of installation, and should be set up warning signs to inform the user: should do the maintenance management of protective cover, the valve's own shield used in dustproof, waterproof, shall not damage and loss, so as not to affect the reliability of the product.
Open valve to handle should be proper force when pulling a piece of, after being import and export pressure balance valve, can smoothly lift to the open position, began to lift velocity shoulds not be too fast, so as not to open the difficult or damage to the handle.
Open valve to restore gas before, must by the professional security first, after confirm no safe hidden trouble, before artificial open.
Strong vibration when the valve closed automatically belong to the normal situation. If the valve fails to maintain normal open, should notify the maintenance.
Connection:

Line connection:
First of all, according to the actual wiring length and line of total pressure drop is not less than 20% of the rated voltage requirements, correct calculation and selection of cable diameter. Line of polarity for the red and black, with the valve control line by introducing explosion-proof junction box flameproof winding hose and reliable on the terminal pressure, external control cable should be used in steel pipe laying, the introduction of explosion-proof junction box, and a reliable pressure welding in the correct polarity on the corresponding terminal, terminal box and steel pipe should be conduction grounding.