DRK-UV-300UV weathering test chamber

Model
Nature of the Manufacturer
Other
Product Category
Plastic soft package testing instrument
Place of Origin
City, Province
Overview
DRK-UV-300UV weathering test chamber
Product Details

Product details


Compliant with international testing standards:

ASTM G 153, ASTM G 154, ASTM D 4329, ASTM D 4799, ASTM D 4587, SAEJ2020, ISO 4892 All current UV aging test standards.

Technical parameter:

Studio size: mm (D×W×H) 450×1170×500

Dimensions: mm (D×W×H) 600×1310×1350

Center distance of lamp: 70mm

The distance between the specimen and the nearest parallel surface of the lamp surface: about 50mm

Wavelength range: UV-A wavelength range is 315~400nm

Radiation intensity: 1.5W/m2/340nm

Temperature Resolution: 0.1℃

Lighting temperature range: 50℃~70℃/temperature tolerance is ±3℃

Condensing temperature range: 40℃~60℃/temperature tolerance is ±3℃

Black panel thermometer measuring range: 30~80℃/tolerance is ±1℃

Temperature control method: PID self-tuning temperature control method

Humidity range: about 45%~70%R.H (light state)/98% or more (condensation state)

Sink requirements: the water depth is not more than 25mm, and there is an automatic water supply controller

Standard specimen size: 75×150mm 48pcs

Recommended use environment for the instrument: 5~35℃, 40%~85%R·H, 300mm away from the wall

Item introduction:

A. Light source

The light source adopts 8 imported ultraviolet fluorescent lamps with a rated power of 40W as the light source. UV fluorescent tubes, distributed on both sides of the machine, 4 on each side. There are UVA-340 and UVB-313 light sources for users to choose from. The luminous spectral energy of UVA-340 lamps is mainly concentrated at the wavelength of 340nm, and the luminous spectrum of UVB-313 lamps is mainly concentrated around the wavelength of 313nm.

We use UVA-340 lamps. Since the energy output of fluorescent light will gradually decay with time, in order to reduce the influence of the test caused by the attenuation of light energy, this test box is used in all eight lamps every 1/1/2 When the life of the fluorescent lamp is 4, an old lamp is replaced by a new lamp, so that the ultraviolet light source is always composed of a new lamp and an old lamp, so as to obtain a constant output light energy. The effective life of the lamp can be about 1600 hours.

BElectrical control

a. The temperature of the blackboard and the condensation temperature are controlled by the controller;

b. The rest basically use imported electronic components;

Irradiance uniformity: ≤4% (at the sample surface)

Blackboard temperature monitoring: The standard Pt-100 blackboard temperature sensor is used to precisely control the surface temperature of the sample during the testing process.

Blackboard temperature setting range: BPT 40-75℃; but the actual maximum temperature limit of the temperature protection device inside the machine is 93℃±10%.

Blackboard temperature control accuracy: ±0.5℃.

c. Water tank temperature monitoring: During the cycle test, there is a test section that is a dark condensation process, which requires saturated water vapor at a higher temperature in the box. When the water vapor encounters a relatively cold sample surface, it will Condensation of dew on the surface of the sample.

The sink is located in the lower part of the box and has a built-in electric heater.

Water tank temperature control range: 40~60℃

d. The test box is equipped with a time controller, the range is 0~530H, and the power failure memory function.

e. Safety protection device:

◆Over-temperature protection in the box: When the temperature in the box exceeds 93℃±10%, the machine will automatically cut off the power supply of the lamp and heater, and enter into a balanced state for cooling.

◆Sink low water level alarm to prevent heater from burning empty.

CStandard sample holder

◆ Several standard sample holders of 75×150mm or 75×290mm are randomly equipped, and the maximum thickness of the sample can reach 20mm.

Non-standard size users need to specify when ordering. When the sample holder is not required, it can be loaded directly. The standard sample holder has 14 rows/side, and a blackboard thermometer is placed in one row on the back. The machine is easy to open the door.

DBox making material

◆ The inner tank of the box is made of SUS304# stainless steel plate

◆ The shell is made of SUS304# stainless steel plate

◆ The sample rack is made of stainless steel and aluminum alloy mesh frame, which is convenient for sample access

EMachine overview

◆ Size: about 1370×1350×530 mm

◆ Weight: about 150 kg

FKUV3 Host requirements for working environment conditions

◆ Power requirements: 220V±5%, single-phase three-wire, 50Hz, 8A, 10A slow-blow fuse is required.

◆ Environment: 5~35℃, 0~80%RH, good ventilation, clean indoor environment.

◆ Work area: about 234×353cm

Drainage: Gutters are required on the floor near the main unit.

For ease of movement, casters are installed at the bottom of the instrument, and U-rings are used to fix the position of the testing machine after the position is fixed.

Control instrument:

The equipment uses a true color touch screen PID temperature intelligent controller, which has high temperature control accuracy and good stability.

Standards compliant:

GB/T14522-93 GB/T16422.3-1997 GB/T16585-96 and other current UV aging test standards

Installation site:

In order to facilitate the cooling and maintenance of the box, the place where the device is installed must meet the following conditions:

1. After installation, there should be enough maintenance space between the equipment and the adjacent wall or other equipment;

2. In order to stably exert the function and performance of the test equipment, a place with an annual temperature of 15°C to 28°C and a relative humidity of not more than 85% should be selected;

3. The ambient temperature of the installation site should not change rapidly;

4. It should be installed on a level ground (use a spirit level to determine the level on the ground during installation);

5. It should be installed in a place without direct sunlight;

6. It should be installed in a well-ventilated place;

7. It should be installed in a place away from combustibles, explosives and high temperature heat sources;

8. It should be installed in a place with less dust;

9. Install it as close to the power supply as possible.

Introduction to structure:

The equipment shell and inner chamber are made of high-quality SUS304 stainless steel, which is processed and formed by the most advanced processing equipment in China. The colors are coordinated and the lines are smooth. It avoids the disadvantage of surface damage caused by long-term use of aluminum plate surface spraying. The equipment studio is equipped with humidification heaters, liquid level switches, blackboard temperature sensors, etc., and eight ultraviolet radiation fluorescent lamps and ultraviolet radiation meters (optional). The bottom of the machine is installed with high-quality fixable PU movable wheels, which can easily move the machine to the designated position, and finally fix the casters.

Precautions:

1. During the operation of the equipment, a sufficient water source must be maintained;

2. In the test phase, the time for opening the door should be minimized;

3. Non-professional operators shall not operate at will;

4. When the equipment fails to troubleshoot by itself, please contact our company;

5. If you need to use it again after a long time of use, you must carefully check the water source, power supply and various components, and then start the equipment after confirming that it is correct; because ultraviolet radiation has strong hazards to personnel (especially eyes), operators should try their best to Reduce exposure to ultraviolet light (contact time should be <1min).

maintenance, maintenance, inspection:

1. Keep the appearance of the box clean and tidy; avoid dust intrusion into the box;

2. Avoid external force hitting the box;

3. Chemicals are prohibited from contacting the equipment;

4. The laboratory should be kept in a dry environment;

5. It is absolutely forbidden to set the temperature to exceed the maximum temperature specified by the equipment;

6. Check the circuit control system before each startup;

7. Confirmation of power supply and grounding wire;

8. Whether the power cord is properly connected in accordance with the specifications, and whether it is properly grounded;

9. Check whether the over-temperature protector has been set (it has been adjusted at the factory, and generally does not need to be adjusted);

10. A ventilation fan should be installed in the laboratory to maintain indoor ventilation;

11. During the spray test, pay attention to observe the water level of the water tank and replenish tap water in time;

12. The waste water discharge system of the equipment must be installed in place;

13. After the test, cut off the power of the whole machine;

14. After each test, take out the sample and clean the inner tank of the equipment;

15. Non-professionals are strictly prohibited from operating this equipment.

Parts list:

controller

TEMI P990 7 inch

South Korea

light tube

UVA 340

America

water pump

Stainless Steel Quiet Corrosion Resistant Pump

custom made

Temperature Sensor

VAISALA

Netherlands

heater

bench

Taiwan

circulation motor

TECO

Taiwan

contact switch

Heaven

Taiwan

main power switch

Fuji

Japan

AC relay

Izumi

Japan

SSR

American Express

America

Equipment appearance supporting device:

1. Equipment packing list 1 copy

2. Equipment instruction manual 1

3. 1 copy of equipment certificate

4. 1 equipment warranty card

5. 5 pieces of wet ball gauze

6. Controller monitoring software CD 1

7. Test sample holder 1 set

Equipment use conditions and installation site requirements:

1. Use environmental conditions

Ambient temperature is 530℃, relative humidity ≤85%R.H;

The installation site must be a flat and vibration-free ground;

The equipment should be kept away from heat sources and flammable and explosive substances;

The installation location should not be exposed to direct sunlight and maintain indoor air circulation;

5. The equipment installation site needs to be clean, and cannot be installed in dusty places or dust outlets, etc.

2. Requirements for storage environment

The ambient temperature of the equipment should be kept within 0℃+45℃

When the ambient temperature is lower than 0°C, (the equipment has been stopped for a long time), the water retained in the equipment should be drained to prevent the water in the pipeline from freezing and swelling and damaging the pipeline.

3. Installation site requirements

The ground is flat, well ventilated, free of flammable, explosive, corrosive gas and dust; there is no strong electromagnetic radiation source nearby;

The ground bearing capacity of the site: not less than 600kg/m2;

Allow adequate maintenance space around the equipment.

A: not less than 600mm

B: not less than 600mm

C: not less than 1100mm