DRK648 Ozone Aging Oven

Model
Nature of the Manufacturer
Other
Product Category
Plastic soft package testing instrument
Place of Origin
City, Province
Overview
DRK648 Ozone Aging Oven
Product Details

Product details

Product Introduction:

The ozone aging box selection of high quality materials, the use of the most advanced domestic processing equipment processing molding, plastic sprayed shell surface, beautiful, smooth. The colors are coordinated and the lines are smooth. The liner is made of imported high-quality stainless steel plate. Indoor sample racks, fixtures and conduits are made of stainless steel materials that are not easily decomposed by ozone and affect ozone concentration. The sample holder can rotate 360 degrees.

 

Product use:

The ozone aging test equipment can be used for rubber products such as rubber, thermoplastic rubber, cable insulation sheath, etc, under static tensile or continuous dynamic tensile deformation, or in the discontinuous dynamic tensile deformation of alternating with static stretching, exposed to the airtight no light contains a constant concentration of ozone in the air and constant temperature test chamber, according to the scheduled time to test the sample, To evaluate the resistance of rubber to ozone aging by the degree of cracking or other properties on the surface of the sample.

 

Technical specifications:

The test equipment is prohibited from:

Test and storage of flammable, explosive and volatile material samples

Testing and storage of corrosive material samples

Testing or storage of biological specimens

Test and storage of strong electromagnetic emission source specimens

 

Equipment model

DRK648

Studio size

Width × depth × height 500*500*600mm

Carton size

Width × depth × height 950*1000*1710mm

The total power

5.5KW

Main performance parameters

Temperature range

RT+10℃+70℃

The temperature deviation

≤±2.0℃

Temperature fluctuation

≤±0.5℃

Ozone concentration

500pphm

Ozone concentration deviation

10%pphm

Humidity range

30%-98%

Humidity deviation

2.0℃3.0℃

The power supply voltage

AC380V/50HZ

Ozone frame

Static (dynamic) tensile test sample frame

Rotation speed

0.1 ~ 2 RPM

Rotating stents

360 degrees rotating sample holder speed adjustable

Rate of rise and fall

Average heating rate is 3~ 5/min (no load)

Fuji temperature control meter imported from Japan (96*96)

 

display

LED digital display

Set way

Push-button control

precision

0.01(display range)

Collect temperature and humidity measurement data

PT100 platinum resistance

The body material

 

 

Inside the box material

1.5mmSUS304 advanced corrosion resistant stainless steel

Carton material

1.5mm cold plate by CNC machine tool electrostatic spraying

Thermal insulation material

The insulation layer is superfine glass wool with a thickness of 100mm and excellent insulation performance.

Enclosure structure

 

 

 

 

Lab door

Single door, equipped with internal and external handle. Both sides of the door and box are equipped with imported sealed silicone rubber, reliable sealing, good aging resistance. Connecting mode: hinge lock, hinge and other hardware accessories for The Japanese "TAKEN".

Watch window

Insulating glass observation window with conductive film and high and low temperature resistant lighting device,

Sealing material

Imported silicone rubber, reliable sealing, good aging resistance

castor

We designed four sets of casters at the bottom of the device, which can be moved and fixed



Heating system

Nickel-chrome electric wire heater

Control mode of heater: PID control mode, using contactless equiperiodic pulse broadening SSR (solid state relay)

Ozone system

Ozone generator for silent discharge tube ozone generator (with low noise volume, high purity)

Ozone generation source: air

Ozone detection probe and shell, electronic circuit board, shielding wire and so on.

Output signal of ozone detection probe: 4 ~ 20mA

Ozone detection probe acquisition accuracy: ≤± 5%F.s

Ozone generator: using voltage silent discharge tube to produce ozone

Ozone Concentration Controller: LED digital Display (PolyU)

Safety device

 

 

Leakage protector

Overtemperature protector in the box

Fan overheat protector

Electrical components

 

 

 

 

 

 

Delixi DH48A Digital Time Relay (made in Shanghai)

Delixi DH48A Digital Time Relay (made in Shanghai)

Schneider Intermediate relay (made in Shanghai)

Schneider Intermediate relay (made in Shanghai)

Electric leakage protector Schneider (made in Shanghai)

Electric leakage protector Schneider (made in Shanghai)

Schneider AC contactor (made in Shanghai)

Schneider AC contactor (made in Shanghai)

Solid state relay Taiwan Yangming

Solid state relay Taiwan Yangming

Fast fuse Shanghai

Fast fuse Shanghai

Contactor Schneider (made in Shanghai)

Contactor Schneider (made in Shanghai)

The standard configuration

Hollow electric tempered glass observation window 1

One copy of operation manual

One copy of certificate of quality

One warranty card

The power cord 4 m

Installation and use conditions

 

 

The power supply

○ AC380V

Voltage fluctuation range: AC380V ±10%

○ frequency fluctuation range: 50Hz ±0.5 Hz

○ The grounding resistance of the PGND cable is less than 4 ohms. Power supply in TN-S or TT mode

Using the environment

Temperature: 5 ° C to 35 ° C, relative humidity: ≤85%RH 

site

The ground is flat, well ventilated, free from flammable, explosive, corrosive gases and dust

No strong electromagnetic radiation source nearby

Reserve proper maintenance space around the device

Ozone aging test chamber meets the standard

This product is designed and manufactured strictly according to the technical parameters of GB/T7762-2003. At the same time meet(ASTM-D1149ASTM-D1171ASTM-D3041)等标准

Special requirements

Can be customized