DRK710A Melt Flow Updater GB/T9643, GB/T3682.1, JB/T5456, ISO1133

Model
Nature of the Manufacturer
Other
Product Category
Plastic soft package testing instrument
Place of Origin
City, Province
Overview
DRK710A Melt Flow Updater GB/T9643, GB/T3682.1, JB/T5456, ISO1133
Product Details

Product details

Features:

1. Using PID intelligent temperature control, the temperature control accuracy is high, which can ensure that the temperature at the top 10 mm of the die in the barrel is within ±0.5℃

2. The key parts are nitrided, with high strength, hardness and small deformation characteristics, and ensure the accuracy and stability of the measurement data;

3. The heating speed is fast. The heater of the instrument adopts a special spring heating ring for hot runner. Its main material is imported nickel-chromium wire alloy, which is better than traditional dynamic heaters.

4. Stronger dry burning resistance, higher power, better heating uniformity and long service life, supporting the instrument to work for a long time at the highest temperature of 450 ℃;

5. The instrument heating adopts a voltage regulating module, which can adjust the voltage and power in a full range. Compared with the traditional solid-state relay on-off control, the heating is more stable and rapid, so that the constant temperature state can be quickly restored after filling;

6. The instrument adopts a customized armored platinum resistance temperature sensor with the highest accuracy class A, and the accuracy is within 0.1℃. Compared with traditional sensors, it has the characteristics of impact resistance, corrosion resistance, vibration resistance, and can be bent at will. Longer life, can ensure the long-term use of the instrument under the highest temperature of 450 ℃ environment.

Technical parameter:

1. Constant temperature accuracy: ±0.5℃

2. Temperature range: 50-450℃ 3. Temperature recovery time: 2min

5. Timing accuracy: 0.1S

6. Test method: MFR quality method, MVR volume method

7. Test range: 0.1-80g/10min (MFR), 0.1-3000g/10min (MVR)

8. Maximum cutting times: 999 times

9. Maximum cut-off time: 999 seconds

10. Piston rod head diameter: Φ9.475±0.015mm

11. Power supply: AC220V±10%; 50Hz; 600W 12. Dimensions: 53×35×56CM