DRK4520B Atomic Absorption Spectrometer

Model
Nature of the Manufacturer
Other
Product Category
Plastic soft package testing instrument
Place of Origin
City, Province
Overview
DRK4520B Atomic Absorption Spectrometer
Product Details

Product details

1. Name

Atomic Absorption Spectrometer


2. Model

DRK4520B


3. Introduction

4520Bhas high precision, humanized designation to fully meet the different requirements of users. Users can choose graphite furnace control, automatic injector, hydride generator and so on.


4. Features

4.1 There are four-lamps position and six-lamps position for option, and the preheat lamp number can be customized, which can short the waiting time of operating process.

4.2 The lamps have the functions of self-optimized, and three-dimensional self-adjustment to maximize the energy. 

4.3 The elements have the functions of negative high-voltage self-memory, wavelength scanning, lamps self-optimization and energy optimization with one key step. 

4.4 It is convenient for the testing results to be exported by various formats and operated by office software. 

4.5 This system can be remote controlled so that its problems can be solved in time with remote control technique.

4.6 Hydride generator can be used. 

4.7 Automatic ignition system can be used.


5. Parameters

Optical system

Wavelength range

190nm-900nm

Grating mark density

1800 lines

Monochromator

Czerny-Turner type

Spectral bandwidth

0.2nm, 0.4nm, 1.0nm, 2.0nm,for multiple auto-switching

Wavelength precision

±0.2nm

Wavelength repeatability

0.05nm

Baseline drift

0.002A/30min

Detectors

Wide spectral range photomultiplier tube

Spectral bandwidth deviation

Copper lamp 324.7nm 0.2nm and bandwidth deviation within ±0.01nm

Light source system

Lamp holders

Four lamp holders for auto-switching (six lamp holders for option)

Lamp power supply mode

400Hz square wave pulse

Lamp current adjusting range

0-10mA average current 

Atomization system

Concentration(Cu)

0.025μg/ml/1%

LOQ (Cu)

0.006μg/ml

Burner

100mm, single-slit titanium metal burner, which is air-cooled pre-mixed type

Precision

RSD≤0.8%

Sprayer

High efficiency glass sprayer of metal set

Atomization chamber

Corrosion-resistant plastic atomization chamber

Safety measures

It has functions of various auto safety protection, acetylene leak alarm and system turn off.

Analysis method

Measuring  methods

Air-acetylene flame method and atomic absorption method for hydride generator

Concentration calculate method

Automatically fit the working curve, calibrate sensitivity and calculate the concentration & content.

Repeat measuring times

1~99 timesautomatically calculate the average value, content, standard deviation and relative standard deviation.

Result printed

Print the stage test data or final analysis report, and the results can be exported to Excel.

Software environment

Windows XP/Vista/Windows7 and Chinese professional software

Instrument parameters

Power supply

AC 220V/50HZ

Power

150VA

Weight

70kg

Working environment temperature

10~35

Working environment humidity

≤80%


6. Auxiliary facilities for option

UV722 UV-visible spectrophotometer 


7. Application fields

4520B can be widely used in the fields of geology, metallurgy, medicine, chemical industry, petroleum, agriculture, environment protection, commodity inspection and some other industries. The analysis and application of trace elements has gradually permeated from inorganic chemistry to organic chemistry in recent years.