DRK-1012 Intelligent Microbiological Detector
Product details
Product Introduction:
DRK-1012 Intelligent biological safety cabinet biological detector by the method of biological safety protection class II biosafety cabinet performance test, accord with the YY0569-2011. II class biosafety cabinets, and other related standards, have personnel protection, product protection, cross contamination three work modes, is mainly used to determine whether the aerosol to stay in a safe, contained in the external contaminants into the safety cabinet work area, and the safe cabinet devices between aerosol pollution is reduced to the minimum, It is applicable to the detection of safety protection performance of grade II biosafety cabinet by medical device testing center, disease control center, metrological verification department and scientific research institute.
Technical Feature:
1.ZIGBEE wireless console can remotely monitor the working status of the machine;
2.The six - way impact sampler, two - way slit sampler and one - way aerosol spray occurred in one;
3.The petri dish inside the two-way slit sampling head rotates at a constant speed for 30 minutes;
4.The upper and lower height and the left and right width of the instrument bracket can be adjusted, which is suitable for testing the safety cabinet of different specifications;
5.Special bacteria spray, spray flow size can be set, atomization effect is good;
6.Embedded high speed industrial microcomputer control;
7.8 inch industrial high brightness color touch screen;
8.USB interface, support U disk data storage;
9.Supporting and moving dual purpose casters;
10.Removable mounting bracket;
11.Special instrument accessory box.
Technical Data:
Main Parameter | Parameter Range | Resolution | Maximum permissible errors |
Impact sampler (six ways) | (12.3~12.6)L/min | 0.1L/min | Overmatch ±2.5% |
Slit sampler (two ways) | 28.3L/min | 0.1L/min | Overmatch±2.5% |
Spray flow | (8~12)L/min | 0.1L/min | Overmatch±5.0% |
Pre-impact pressure of the flowmeter | (-20~0)kPa | 0.01kPa | Overmatch±2.5% |
Slit flowmeter front pressure | (-20~0)kPa | 0.01kPa | Overmatch±2.5% |
Spray flowmeter front pressure | (0~300)kPa | 0.1kPa | Overmatch±2.5% |
Working Temperature | (0~50)℃ |
Data storage capacity | 100 Group |
Hepa filter characteristics | According to 0.3umfiltration efficiency of the above particles≥99.99% |
Dimension | (L 520×W 350×H 640)mm |
Stent Size | (L1500×W150×H600)mm(Maximum) |
Bracket adjustable height | (550~700)mm,(700~910)mm |
Bracket adjustable width | (800~1500)mm |
Instrument noise | <65dB(A) |
Weight | 35kg |
Main Power | AC220V±10%,50Hz |
Power consumption | <600W |
Remote terminal power adapter | Imput :AC100~240V 50/60Hz Output:DC15V 3A |
Remote control terminal working hours | >5h |