DRK-1100 Automatic Colony Counter
Product details
Technical Feature:
DRK-1100 automatic colony counting instrument is a high-tech product developed for microbial colony analysis and microparticle size detection. It USES its powerful software image processing function and scientific mathematical analysis method to analyze microbial colony and microparticle size detection, and counts quickly and accurately. It is applicable to the microbiological testing of hospitals, scientific research institutes, health and anti-epidemic stations, disease control centers, inspection and quarantine, quality and technical supervision, environmental testing institutions and pharmaceutical, food and beverage, medical and health supplies industries.
1.Equipped with instrument calibration, as well as a variety of graphic labeling, measurement functions;
2.Detection methods such as monochromatic bacterial colony recognition and simultaneous and automatic recognition of multi-color bacterial colonies
3.Automatic adhesion segmentation, manual segmentation, counting back function, counting results accurate and fast
4.Powerful image processing software
5.High resolution color industrial camera
6.Select regional statistics, and output the data of colony diameter, roundness, circumference, area and number instantly.
7.Data storage and query functions;
8.Report data can be exported directly in EXCEL format or printed directly
9.One standard image processing PC
Standard:
GB/T4789.02-2003
ISO 11737
Model &Specifications:
Model | Specifications |
DRK-1100 | Colony counting, Inhibition zone、Spiral statistics |
DRK-1100A | Clony counting ,inhibition zone |
DRK-1100B | Colony counting |
Technique Data:
Main Parameter | Parameter scale |
CMOS Specifications | 10 megapixels, true color |
Image shoot | Automatic focusing, automatic white balance, automatic color temperature control |
Photo camera | Front opening, automatic elimination of external interference, automatic center, camera camera |
Upper light source | Multi - direction transmission light, light source brightness adjustable |
Down light source | Bottom transmission darkroom shooting system |
The type of plating | Pour, coating, membrane filter, 3M Petrifilm paper and other types of plates |
Counting rate | 500 colonies <1 second |
Automatic impurity removal | According to the shape, size, color and other aspects of the difference, automatic impurity removal |
Colony morphology analysis | The area, circumference, roundness, maximum diameter, minimum diameter and circumference of each colony were analyzed automatically |
Statistical area selection | Fixed circle, semicircle, circle, rectangle, sector, arbitrary region selection |
Inhibition zone | Automatic measurement of bacteriostatic zone | The diameters of multiple bacteriostatic rings in petri dishes were measured automatically and accurately |
The bacteriostatic zone was measured manually | The edge of the fuzzy bacteriostatic circle was precisely measured by 2-point circle |
Image processing | Image intensification | Image adaptive enhancement, color component enhancement, colony edge sharpening, image leveling |
Image filtering | Low pass filter, high pass filter, gauss high pass, mean pass filter, gaussian pass filter, sorting filter |
Edge detection | Sobel detection、Roberts detection、Laplace detection、Vertical detection, horizontal detection |
Vision control | Grayscale conversion, negative phase conversion, RGB channel brightness, contrast, Gama adjustment |
Morphological algorithm | Corrosion, expansion, open operation, closed operation |
Image Segmentation | RGB segmentation, gray segmentation |
Mark measurement | Calibration of instrument | The system has its own calibration function |
Colony marked | Line Angle rectangle broken line curve of a variety of graphics |
Measurement of the colony | Measurement of a variety of shapes of straight Angle rectangular circular circular sector curve |
Colony recognition | Colony color recognition | According to the color of the colony, automatically identify the selected color of the colony statistics |
Polychromatic colony recognition | According to the background color, the deviation statistics of all color colonies were carried out, and a maximum of 7 color colonies were identified |
Statistical data | Data export | Statistics can be printed in Excel format or in data report format |
Data storage | Images and all results are stored in a database |
Data Query | Colony images and statistical results were queried by date |
Automatic paper sensitivity analysis | The system has all the data of the 14th edition of NCCLS |
Basic flora count | E. coli, staphylococcus aureus count, in line with the national standard gb4789.3-2010 plate count method, automatic count method |
Spiral statistics | Helical statistics were performed on petri dishes inoculated with helical inoculation, and the results were verified |
Working Temperature | (0~50)℃ | Frame Dimension | (L340×W355×H400)mm |
The power consumption of the host | ≤50W | Frame Weight | 7.5kg |
Power adapter | Input: AC100~240V 50/60Hz Output:DC24V 2A |