DRK-1000T Mask filter material performance test bench

Model
Nature of the Manufacturer
Other
Product Category
Plastic soft package testing instrument
Place of Origin
City, Province
Overview
DRK-1000T Mask filter material performance test bench
Product Details

Product details

Main uses:

The mask filter material performance test bench is used to quickly and accurately detect the  flow and other performance indicators of various planar materials, such as glass fiber, PTFE, PET and PP with efficiency, resistance and filtration speed features.


Test standards:

GB 2626-2019 Respirator protective self-imbibition filter respirator against particulate matter

GB 19082-2009 Technical requirements for disposable protective clothing for medical use

GB 19083-2010 Technical requirements for medical protective masks

GB/T 32610-2016 technical specification for daily protective masks

YY 0469-2011 medical surgical mask

YY/T 0699-2013 disposable surgical mask

EN 1822-3:2009 high efficiency air filters (sub-high efficiency, high efficiency, ultra-high efficiency) - part 3: filter paper test

ISO 29463-3:2001 high efficiency air filters and filters - part 3: filter paper test

IEST-RP-CC021.3:2009  HEPA and ULPA filter material test

JG/ T 22-1999 test method for performance of air filters for general ventilation

ANSI/ASHRAE 52.2-2012 diameter efficiency test method for general ventilation air filters

EN 779-2012 (air filters for general ventilation - determination of filtration performance)

JISB 9908-2011 (test method for air filters and electric air cleaners for ventilation).

 

Main features:

1. Pressure difference measurement adopts imported high-precision pressure difference transmitter to accurately measure sample resistance.

2. The efficiency test adopts two laser particle counters of well-known brands in the industry, and simultaneously detects the concentration of particles in the upstream and downstream samples to ensure the authenticity and accuracy of the samples adopted in the upstream and downstream

3. The fog system adopts Laskin nozzles to release the multi-dispersed particle size (single dispersed particle size is optional), and the fog concentration can be adjusted quickly and steadily

4. Touch screen control, simple and intuitive operation

5. Test results are automatically calculated and displayed by the system and printed out

6, data port: external storage card, can export data, do not worry about data loss

 

Main technical parameters:

1. The range of test flow was 5 ~ 100L/min (standard condition 32L/min), ±1%

2. Specification of test sample: 100cm 2, various specifications of test fixture can be customized according to customer requirements.

3. Resistance test: range 0 ~ 1500Pa, accuracy up to ±0.025, automatic return to "0" function

4. Efficiency test: efficiency range 0 ~ 99.999%, penetration rate 0.001%.

5. Test particle size: 0.1, 0.15, 0.2, 0.25, 0.3, 0.5, 1.0, 2.0, 5.0, 10.0 m (select the corresponding sensor according to customer requirements)

6. Aerosol dust source: salt aerosol (NaCL, KCL,) oil aerosol (DEHS, DOP, PAO) and PSL (when ordering)

7. Test time: resistance was tested separately for 10s, and both efficiency and resistance were tested for 60s

8. Temperature: 0 ~ 50C°,±0.5C°. Humidity: 0 ~ 99%RH,±3%.

9. Atmospheric pressure: 800 ~ 1100hpa,±0.2%

10. Power supply: AC 220V 50HZ 1.5kw

11. Air source requirements: 0.8mpa, 200L/min

12. Overall size: 700*730*1480mm (length * width * height)

13. Product weight: 180Kg