DRK160 Thermal Deformation Vicat Analyzer

Model
Nature of the Manufacturer
Other
Product Category
Plastic soft package testing instrument
Place of Origin
City, Province
Overview
DRK160 Thermal Deformation Vicat Analyzer
Product Details

Product details

Product Introduction 

The DRK160 Thermal Deformation Vicat Analyzer is used to measure the softening temperature of thermoplastic materials and the thermal load deformation temperature as an indicator of quality identification and material properties. This product is widely using in plastics, rubber chemical companies and scientific research institutions.

 

Technical Parameters

1. Temperature Control Range: Room Temperature to 300 0C

2. Accuracy of temperature measurement: +0.5 0C

3. Uniform heating rate:

A Speed: 5 + 0.5 0C/6 min

B Velocity: 12 +1.0 0C/6 min

4. Deformation measurement range: 0-1 mm

5. Precision of High Precision Digital Display Micrometer: +0.003mm

6. Deformation accuracy: +0.005mm

7. Maximum load of softening point test: GA=10N+0.2N; GB=50N+1N

8. Maximum heating power: <3000W

9. Power supply, frequency, maximum current: 220V 50HZ 30A

10. Span: 64mm, 100mm or continuously adjustable

11. The specimen is laid out horizontally.

12. Accuracy Level: Level 1

 

Product Features

1. Measurement of Vicat softening temperature. (A law)

2. Measurement of load deformation temperature.

3. During the test process, in order to prevent the overflow of oil with excessive oil volume or large expansion coefficient from thermal expansion, the machine is specially equipped with an overflow oil recovery device.

4. Cooling mode: natural cooling, water cooling or nitrogen cooling. It has the upper limit temperature protection function and the automatic lifting function of the test stand (optional). The heating medium is methyl silicone oil.

5. The medium tank is equipped with 45_double helix automatic mixing system. The oil tank has special structure, good temperature uniformity and accuracy (+0.5 0C).

 

Technical Standard

1. ISO75-1:1993 "Determination of Plastic-Load Deformation Temperature".

2. ISO306:1994 "Determination of Vicat Softening Point Temperature of Plastics-Thermoplastics".

3. 3GB/T1633-2000  “Measurement of Vicat Softening Point Temperature of Thermoplastic Plastics".

4. GB/T1634-2001 "Plastics-Load Deformation Temperature Measurement"