G0003 - 5 - Glow Wire Thermocouple
Product details
The Glow Wire Thermocouple allows for a test to be carried out assessing the effects of
heat generated by electrical faults and overloads within electrical equipment in solid insulated
materials and non-metallic enclosures containing or supporting current carrying parts with
regard to ignitability and propagation of flame.
An electrically heated small loop of resistance wire “Glow-wire" is applied to those insulation
surfaces likely to be subjected to heat generated by fault conditions or overloads. The
temperature and duration of application of the glow-wire is dependant upon the operational
and service conditions of the equipment under test. The glow-wire thermocouple is an integral
part of this test.
The glow wire must be introduced at right angles to the test specimen with a force of 0.8
to 1.2N and the glow-wire and test specimen must be moved towards each other over a
distance of up to 7mm.
Calibration of thermocouple is to be carried out at 960˚C. Preferred test temperatures are:• 650˚C• 750˚C• 850˚C• 960˚C
Applications:
• Electro technical equipment.
• Solid combustible materials.
• Solid electrical insulating materials.
• Insulation surfaces
Features:
• Complies with very stringent requirements of the standards.
• Certified by FastLab. ECEFast NATA accredited laboratory No.5473.
Options:
• TS-GLOW-ASSNATA– 0.5mm diameter NATA certified Glow-Wire Thermocouple.
• TS-GLOW-ASSNATA1 – 1mm diameter NATA certified Glow-Wire Thermocouple
Standards:
• AS/NZS 60695.2.10:2000 – Glowing Hot-Wire based test method.