Welcome Customer !

Membership

Dongguan Tuancheng automation equipment Co., Ltd
Free Member ·1YRS
,
Other

Main Products: 发电机

Xwboo>Products

Dongguan Tuancheng automation equipment Co., LtdFree·1YRS

  • E-mail

  • Phone

    +86-769-23836636,+86-769-22768286

  • Address

    Wentang Road,Chashang industrial zone #18,Dongcheng,Dongguan,Guangdong,China

Contact Now

R449 Automatic Voltage Regulator

Model
Nature of the Manufacturer
Other
Product Category
Generator AVR
Place of Origin
City, Province
Overview
R449 Automatic Voltage Regulator
Product Details
Introduce
Product:
User manual:
Software Download:

Product description:

The circuitry of the R449 Automatic Voltage Regulator (AVR) provides closed loop control of the alternator output voltage by regulating the exciter field current. Which can be powered by either AREP or the PMG field excitation systems and is fitted as standard on 8100 Series Alternators & 9100 Series Alternators.

R 449 voltage Regulator is of a shunt type. It is designed to fit as Standard on A50 to A54 alternators. It can be supplied with power either by a power VT, or by the AREP field excitation system, or by a single-phase or 3-phase PMG, Using the R 726 external module, the regulator can control the power Factor (2F) and can match the alternator voltage to the mains voltage (3F) prior to synchronization. The circuitry of the R449 automatic voltage regulator provides closed loop control of the alternator output voltage by regulating the exciter field current.    

 

Main features: 

1 、Quad-rature droop adjustment

2、Alternator output voltage adjustment

3、Stability adjustment

4、LAM Threshold (under speed) adjustment

5、Excitation ceiling adjustment

6、Selection of single phase or three phase voltage sensing

7、Selection of normal or rapid response time

8、50 Hz or 60 Hz frequency option

9、Remote voltage adjustment option

10、LAM enable/disable option


Specifications:

Normal AVR supply power:2 

 Auxiliary windings(X1,X2,and Z,Z2)

Shunt supply:150V-50/60Hz

Rated overload current:10A,10s

Electronic built-in(overload,short 

 circuit,and loss of sensing)

Protection of power inputs by fuses F1

Voltage Sensing:5VA insulated transformer with input voltage taps at:

Terminals 0-110V=95 to 140V

Terminals 0-220V=170 to 260V

Terminals 0-380V=340 to 520V