Overview
Short Description: Mass flow accuracy: ±[0.2% +(zero stability /flow rate×99%)]Mass flow repeatability: ±(1/2) ×[0.2% +(zero stability /flow rate×99%)]Density range: 0.2 g/cm3~3.5g/cm3Density accuracy: ±0.002g/cm3Temperature range: -60℃~+200℃ (-60℃~+300℃,-200℃~+100℃)
Product Details
Short Description: Mass flow accuracy: ±[0.2% +(zero stability /flow rate×99%)]Mass flow repeatability: ±(1/2) ×[0.2% +(zero stability /flow rate×99%)]Density range: 0.2 g/cm3~3.5g/cm3Density accuracy: ±0.002g/cm3Temperature range: -60℃~+200℃ (-60℃~+300℃,-200℃~+100℃)

Introductions

Coriolis mass flow meters patented and developed by our company are the leading meters for precision flow measurement. And with good performance, Its accuracy is very high, with low requirement on flow status and pressure loss. The meters offer direct mass flow, volume flow, density, and temperature measurement of liquids and slurries — without the need for additional manual calculations, or estimations.

The meters are with unsurpassed performance in even the harshest operating environments. They have no moving parts inside, no any special mounting and low working condition requirements. Every meter is available with stainless steel wetted parts and a wide variety of process connections to meet your need. The meters carry hazardous area approval for P. R. China.

Principles of Measurement

The structure of Coriolis Mass Flow Meters consist of a pair of bended tubes. The principle is to detect Coriolis force on a pair of bended tubes to measure the mass flow of the inside tubes.

A new force—Coriolis force would appear while meeting two conditions: (1) bended tubes vibrating with a fixed frequenc, (2) fluid flowing in tubes. This force was produced upon the mixture from vibrating force and flowing force by fluid in tubes. And tubes would be wresting symmetric the center line because the force forced. Two displacement sensors on sides of tubes detect output electric signals, handle the signal, and then get the mass flow.

Technical Specifications

Mass flow accuracy±[0.2% +(zero stability /flow rate×99%)]
Mass flow repeatability±(1/2) ×[0.2% +(zero stability /flow rate×99%)]
Density range0.2 g/cm3~3.5g/cm3
Density accuracy±0.002g/cm3
Temperature range-60℃~+200℃ (-60℃~+300℃,-200℃~+100℃)
Temperature accuracy±1℃
Output of current loop4mA~20mA
Output of frequency/pulse0Hz~10kHz
CommunicationRS485/MODBUS or HART
Contactor capacity and form of the relay24V/0.1A, normal open