N530 Gas Permeability Analyzer
Application
To test the gas (O2, N2, CO2 etc) transmission rate (GTR) of packaging materials, such as plastic film, composite film, coextrusion film, aluminum-plated film, aluminum foil, infusion bag, sheets, paper, paper board, solar battery panel, cellophane, ceramics and porcelain, and various containers such as bag, pouch, bottle, can, bowl, box, widely used in the industries of food, pharmaceuticals, personal care, household, electronics and so on.
Working principle
Pressure differential method. Fix the test sample in the middle of test chamber to separate the chamber into upper room and lower room, between which there is a constant pressure difference. The gas molecules penetrate through the sample from higher pressure room into lower pressure room, then the system monitor the pressure change in lower pressure room and calculate the gas transmission rate.
Test range | 0.02~50000cm3/m2 ·24h·0.1Mpa (0.02~600000 optional) |
Test accuracy | 0.01 cm3/(m2·24h·0.1Mpa) |
Temperature range | 5~50 ℃ |
Temperature accuracy | ±0.01℃ |
Humidity range | 0%RH (30~90%RH optional) |
Humidity accuracy | ±2%RH |
Vacuum degree | <10Pa |
Vacuum resolution | 0.1Pa |
Test pressure | -0.1~+0.1MPa |
Test gas | O2, CO2, N2 etc |
Sample thickness | ≤2mm |
Sample size | Φ110mm, test area 50.24cm2 |
Gas supply pressure | 0.2~0.8MPa |
Instrument size | 800x560x400mm |
Power supply | 220V 50Hz |
GB/T 1038, ISO 2556, ISO15105-1, ASTM D1434, YBB, JIS K7126-A
1. Temperature control: International advanced electromagnetic technology, program controlled, automatic temperature rise and fall, speed adjustable. Precision 0.01℃.
2. Automatically keep pressure difference.
3. Unique chamber and gas flow design, specialized sensor, high precision and stability.
4. Adaptable to environment, not affected by environment temperature.
5. Applicable to high barrier material and low barrier material; can test aluminum foil.
6. Real time curves display of transmission rate, pressure, pressure difference and temperature.
7. Simple software interface, easy to use, auto save data and report, can print curves.
8. Wholly automatic, over pressure protection, multiple safety protection.
9. Standard film calibration and pressure calibration.
10. Excellent hermetic sealing of test chamber, can test ceramics and porcelain.
1. Temperature control: International advanced electromagnetic technology, program controlled, automatic temperature rise and fall, speed adjustable. Precision 0.01℃.
2. Automatically keep pressure difference.
3. Unique chamber and gas flow design, specialized sensor, high precision and stability.
4. Adaptable to environment, not affected by environment temperature.
5. Applicable to high barrier material and low barrier material; can test aluminum foil.
6. Real time curves display of transmission rate, pressure, pressure difference and temperature.
7. Simple software interface, easy to use, auto save data and report, can print curves.
8. Wholly automatic, over pressure protection, multiple safety protection.
9. Standard film calibration and pressure calibration.
10. Excellent hermetic sealing of test chamber, can test ceramics and porcelain.