8DIN+4AIN+4DO Remote IO Module (MQTT, Modbus)

Model
Nature of the Manufacturer
Other
Product Category
Industrial IO Modules
Place of Origin
City, Province
Overview
The M150 is designed for IIOT Application and Industrial Automation, it provides 8DIN+4AIN+4DO, compatible with MQTT, Modbus RTU, Modbus TCP protocols, equips 1-2 Ethernet ports and 1 RS485 port.
Product Details
IntroductionFeaturesSpecificationsDownloadApplications
The M150 Ethernet Remote I/O module provides a RS485 interface, through the RS485 bus, it can cascade Modbus RTU I/O devices or Modbus RTU meters, e.g.: a variety of digital input or digital outputs, analog inputs or outputs, thermal resistance IO module combination, save costs. At the same time, the Ethernet Remote I/O module has register mapping function, the cascade Modbus RTU I/O data are automatically collected to the mapping memory area, the Modbus TCP Client query without waiting then can get a quick response to meet the industrial timely requirements.
 

The M150 Ethernet Remote I/O module provides 8 optical-isolated digital inputs, supports max. 700Khz high speed pulse counter, 4 isolated 12bits analog inputs, supports 0~5V,0~10V,4~20mA,0~20mA analog signal, 4 digital outputs, supports 10Hz~300Khz high speed pulse output or relay outputs. All of the I/O with high sampling frequency and special filtering strategy to ensure it’s reliable.

The M150 Ethernet Remote I/O module can work at 12~36VDC with anti-reverse protection design. Also, it provides 1channel 12~36VDC power output for external device to save wiring cost.
1. Embedded 32-Bit High Performance Microprocessor MCU, inbuilt watchdog;
2. Power supply 12~36VDC with over voltage and phase-reversal protection;
3. Management and configuration via LAN connection configuration software for easy operation and maintenance;
4. Support Web real-time monitoring and Web debugging;  
5. DO1 support PWM output;
6. Integrated 10/100M adaptive Ethernet module, supports Modbus TCP protocol;
7. 8 optical isolated digital input, supports max. 700Khz high speed pulse counter;
8. 4 digital output or relay output, supports 10Hz~300KHz high speed pulse output;
9. 4 isolated analog input, 12-bit resolution, supports 0~20mA,4~20mA,0-5VDC, 0-10VDC;
10. High sampling frequency and special filtering strategy to ensure reliability;
11. 1 RS485 Serial port, supports Modbus RTU Master or Slave, can extend I/O modules;
12. Supports register mapping function and extend I/O inquiry strategy;
13. Provides 1 channel 12~36VDC power source output for external device, saving wiring cost;
14. LED instructions work status, with reset button to reset, easy on-site installation and commissioning;
15. Using metal shell, protection class IP30. Metal shell and system security isolation, especially suitable for industrial applications in the field;
16. Small size, L105 * W88 * H30mm, compatible wall installation and DIN35mm industrial rail installation.

M150T Specifications

 

Ethernet Remote I/O Module Specifications

• Digital Input

Sensor Type

Wet Contact (NPN or PNP), Dry Contact

I/O Mode

DI or Event Counter

Dry Contact

• On: short to GND=1
• Off: open=0

Wet Contact (DI to COM)

• On: 10 to 30 VDC=1
• Off: 0 to 3 VDC=0

Counter Frequency

Max. 700kHz(Only the 1st Channel can be used as high speed pulse counter)

Digital sampling frequency

500Hz

Digital filtering strategy

Continues 3 times

Isolation

Optical Isolated,3k VDC or 2k Vrms

• Digital Output

Type

Sink 

I/O Mode

DO or Pulse Output

Pulse Output Frequency

10Hz~300KHz(Only the 1st Channel can be used as high speed pulse outputs)

Over-Voltage Protection

50 VDC

Over-Temperature Shutdown

175°C (typical), 150°C (min.)

Load Current

Max. 500 mA per channel

Digital sampling frequency

500Hz

Isolation

If DO is Sink type, then no isolation. If it is Relay, then is electrical isolation.

• Analog Input

Type

Differential input

Resolution

12 bits

I/O Mode

Voltage / Current (jumper selectable)

Input Range

0 to 10 VDC, 0 to 20 mA, 4 to 20 mA, 4 to 20 mA

Accuracy

±0.1% FSR @ 25°C
±0.3% FSR @ -10 and 60°C
±0.5% FSR @ -40 and 75°C

Sampling frequency

20Hz

Built-in Resistor for Current Input

162 ohms

Isolation

Electrical isolation

• Working Power Requirements

Input Voltage

12~36VDC, Peak Voltage:+40VDC, Power consumption: Less than 3W;

Input Current

139 mA @ 24 VDC

• Power Output

Output Voltage

12~36VDC

Output Current

139 mA @ 24 VDC

• LAN

Ethernet

10/100 Mbps, RJ45 ports

Protection

15KV ESD Protection

Protocols

Modbus TCP, TCP/IP,MQTT,TCP Server,TCP Client 

Max. TCP Connection

5

• Serial Port

RS485

MODBUS- RTU Protocol

Protection

15KV ESD Protection

Modbus Slave address

1~255

Baud Rate

1200,2400,4800,9600,19200,38400,57600,115200,128000Bps;

Mapping registers

Bit Type: 300 Registers, 16-Bit Type: 300 Registers.

• Physical Characteristics

Wiring

I/O cable max. 14 AWG

Dimensions

105 x 88 x 30 mm

Weight

Under 205 g

Mounting

DIN rail or wall

• Environmental Limits

Operating Temperature

Standard Models: -10 to 60°C (14 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)

Storage Temperature

-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity

5 to 95% (non-condensing)

Altitude

Up to 3000 m








 

Typically applications:

 

1.      BTS Monitoring;

2.      Security Alarm System applications;          

3.      Supervision and monitoring alarm systems;

4.      Automatic monitoring system;             

5.      Vending Machines security protection;

6.      Pumping Stations, Tanks, Oil or Water levels;

7.      Buildings and Real Estate;

8.      Weather Stations; 

9.      River Monitoring and Flood Control;

10.   Oil and gas pipelines;  

11.   Corrosion protection

12.   Temperatures, water leakage applications;

13.   Wellheads, boat, vehicle;

14.   Energy saving, street lights control system;

15.   Valve controls;

16.   Transformer stations;   

17.   Unmanned machine rooms;

18.   Control room application;

19.   Automation System, M2M;

20.   Access Control System;

21.  PLC Gateway, PLC Remote Monitoring.