VLF with dielectric loss testing
Product Description
BVLF (Very Low Frequency) Testers are suitable for testing power cables, transformers, switchgear, rotating machinery and other electrical apparatus.
The product combines modern advanced digital variable frequency technology and micro computer control together, therefore, it can realize the full automatic voltage boost, stepdown, measurement and protection as well as the manual intervention in the process of automatic voltage boost. The full electronic design ensures the small size and light weight. The big LCD screen ensures the clear and visual display, and can display the output sinusoidal wave form. The printer outputs test reports. In addition, the product has features as follows:
1. Data of current, voltage, wave form can be directly sampled at high voltage side, so the data is real and accurate.
2. Overvoltage protection: If the output exceeds the set limit of voltage, the instrument will shut-down to protect itself, the actuation time is less than 20ms.
3. Overcurrent protection: It is high-low voltage dual protection in the design, the accurate shut-down protection can be made according to the set value at high voltage side; If the current on low voltage side exceeds the rated current, the instrument will take shut-down protection, the actuation time are both less than 20ms.
4. A high voltage output protective resistor is provided in the voltage boost body in the design and this eliminates the need of additional protective resistor connected outside.
Technical parameters:
1. Voltage(peak) 0-80kv, sensitivity: 0.1kV, accuracy: 1 %
2. Waveform:ultra-low frequency sine wave, DC voltage, positive and negative voltage peakerror: ≤ 3%, voltage waveform distortion: ≤ 1%
3. Frequencyrange: 0.1 Hz 0.05 Hz 0.02 Hz Load range (ultra-low frequency test): 10nF-10μF
4. Current:Measurement range: 0-70 mA, sensitivity: 1 μA, accuracy: 1 %
5. Dielectricloss.
Ultra lowfrequency sine wave voltage range: 1-80 kVrms
Load range: 50nF - 5 μF
Resolution: notless than 1x10-6
Accuracy: notless than 1x10-3
Measurementrange: 1x10-3 - 21000x10-3
Dielectricmeasurement frequency: 0.1Hz
Capacitancerange: 50nF-5μF
Resistancerange: 30MΩ-10GΩ
Volume:48cm*28cm*58cm
Weight: 45kg
6. Operatingconditions: indoor, outdoor; temperature: -10℃~+40℃; humidity: ≤85%RH
7. Power supply:frequency 50Hz,60hz, voltage 100v -260V±5%.
8. usbcommunication port.
9. Useconditions: indoor, outdoor; temperature: -10℃~+40℃; humidity: ≤85%RH
10.Power supplyfuse: see table 3
11. Powersupply: voltage 220V±5%, 50±5Hz
12. Principle ofdielectric loss test

Electrical modelof cable insulation
Good insulationresistance tends to infinity; capacitive impedance is related to cablecharacteristics and length; resistive current is very small and in phase withthe voltage; capacitive current has a fixed value and is 90° behind the voltagein phase

l The higher the resistivecurrent, the lower the insulation capacity
l The higher the resistivecurrent, the higher the dissipation angle δ
l The larger the angle ofdissipation, the larger the tangent value
l The degree of insulation ageingcan be determined by measuring the tangent of the dissipation angle