Online UPS Full Series 10-300K

Model
Nature of the Manufacturer
Other
Product Category
UPS (Uninterruptible Power Supply)
Place of Origin
City, Province
Overview
Low Frequency UPS
Product Details

Main parameters

Model10KVA20KVA30KVA40KVA60KVA80KVA100KVA120KVA160KVA200KVA250KVA300KVA
Capacity8KW16KW24KW32KW48KW64KW80KW96KW128KW160KW250KW300KW
Input
Rated voltage208/220 Vac three-phase
Voltage range208/220 VAC(+15%,Can be set through the LCD panel)
Frequency range40-70Hz(Automatically select synchronization range according to grid frequency)
Range(HZ)50±5%(±10%)Bypass synchronization tracking
Rectifying pulse number6 pulse rectification6/12 pulse rectification
Phase system3φ4W+PE(Three phase five wire system)
Battery voltage(VDC)384
Battery quantity(section)Standard with 32(30~34, can be set through the LCD panel)Standard 40 knots(38~42 knots,can be set by LCD panel)
Output
Power factor0.8/0.9
Voltage(V)L-N: 110±1%   L-L: 220±1%
Three-phase 99% load unbalance voltage stability≤2%,Allow 99% imbalance
Frequency(HZ)Normal power, tracking the frequency of power, Grid abnormal. 50±0.2%
Transfer time(ms)0
Parallel operation mode(parallel type)   8 parallel machine
Waveform distortionLinear loadTHD<3%; Nonlinear loadTHD<5%
Overload capacity125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the load can automatically restore the inverter
Crest factor>3:1
Others
IndexStandard with no transfer time maintenance bypass switch
Communication function Provides dry contract communication and RS232/RS485, Optional SNMP option to achieve intelligent monitoring of UPS
Panel display LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load ,battery voltage, battery charge and discharge current, etc
DisplayLCD 7" touch screen display
The audio noise(dB)<65(within 1 meter)
Alarm functionBattery low voltage, abnormal power supply, overload, UPS failure, over temperature protection
ProtectionInput over voltage, battery under voltage, overload, short circuit, over temperature protection
Cooling wayForced cooling
Operating temperature(℃) 0~40
Humidity0~95%, non-condensing
Electromagnetic compatibilityConform GB7260.2
Size(W*D*H)(mm)800*800*16001100*800*18001405*1113*2005
Weight0.480.560.891.081.281.381.681.98

Features

High intelligence and reliable power supply:
CNG330 provides maximum protection for vital mission-critical networks, security applications (electro- medical)and industrial applications thanks to its outstanding mechanical and electrical design.
The load is powered continuously by the inverter with a filtered, stabilized and regulated sine wave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges.
 The CNG330 uses on-line double conversion technology (VFI) with isolation transformer on the inverter output.
The CNG330 is supplied with Watch & Save 3000 software as standard and can be remotely monitored
using the Power Net Guard system from anywhere in the world. Additional battery extension packs allow the standard battery routine to be extended up to several hours.

Minimum impact on supplies easy sources: 
 Input current distortion <4% for the CNG330 with filter with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enable CNG330 to deliver maximum performance levels regardless of the installation environment. With these input features CNG330 can achieve significant savings in terms of sizing and power supply sources isolation transformers and generators over less sophisticated power systems.

Maximum battery care:
Battery deep discharge protection;
Temperature compensating charger;
Built-in automatic and manual battery test feature.

Simple to install:
Capability to install the UPS into any distribution system(neutral not required on rectifier input);
Capability to separate the rectifier/bypass power networks and to power these from two separate sources, without Galvanic isolation (Necessary on UPS without an output transformer).

High reliability:
Extremely high short-circuit current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output;
Full microprocessor control with no-break static and manual bypasses;
IGBT technology.

Other characteristics
0.8 power factor make CNG330 suitable for powering ICT and Industrial loads;
High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD with several languages;

Back feed protection: to avoid energy feeding back into the mains supply cause a fault occur.

Maximum reliability and availability
Connect up to 6 units in parallel or N+1 redundancy, even of different power ratings.The UPS continue to work in parallel even if one of the interconnecting communication cables is disconnected (CLOOSED LOOP).

Low consumption level:
CNG330 can achieve efficiencies >98% thanks to selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity when the mains fail.


Advance communication

Compatible with TeleNetGuard for remote maintenance;
Advanced, multi-platform communication for all operation systems and network environments: Watch & Save 3000 monitoring and shut-down software included, with SNMP agent, for Windows 2008, Vista,2003, XP; Mac OS X, Linux, Novell and most popular Unix operating systems;

The UPS is supplied with a cable for direct connection to the PC(Plug and Play);
RS232 double Serial port; Installation slot for an Emergency Power Off (EPO) interface to allow the UPS to be switched off remotely in an emergency;
Generator interface: enables desynchronisation of the UPS output from a generator supply which may be subject to phase and frequency variations. The interface also enables more economic use of the battery charge.

Expandability:
The units can be connected in parallel up to 8 units to increase power availability or redundancy. The single
module or the system can be expanded any time to suit power requirements without influencing the initial investment.