| Models | CNS4830S60 | CNS4840S60 | CNS4850S80 | CNS4825U60 | CNS4830U60 | CNS4835U80 |
| AC mode |
| Rated input voltage | 220/230Vac | 110/120Vac |
| Input voltage range | (170Vac~280Vac) ±2% (90Vac-280Vac) ±2% | (90Vac~140Vac) ±2% |
| Frequency | 50Hz/ 60Hz (Auto detection) |
| Frequency Range | 47±0.3Hz ~ 55±0.3Hz (50Hz); 57±0.3Hz ~ 65±0.3Hz (60Hz); |
|
| Overload/short circuit protection | Circuit breaker |
| Efficiency | >95% |
| Conversion time (bypass and inverter) | 10ms (typical) |
| AC reverse protection | Available |
| Maximum bypass overload current | 40A |
| Inverter mode |
| Output voltage waveform | Pure sine wave |
| Rated output power (VA) | 3000 | 4000 | 5000 | 2500 | 3000 | 3500 |
| Rated output power (W) | 3000 | 4000 | 5000 | 2500 | 3000 | 3500 |
| Power factor | 1 |
| Rated output voltage (Vac) | 230Vac | 120Vac |
| Output voltage error | ±5% |
| Output frequency range (Hz) | 50Hz ± 0.3Hz 60Hz ± 0.3Hz |
| Efficiency | >90% |
Overload protection
| (102% < load <125%) ±10%: report error and turn off the output after 5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds; | (102% < load <110%) ±10%: report error and turn off the output after 5 minutes; (110% < load < 125%) ± 10%: report error and turn off the output after 10 seconds; (Load >150% ±10%): report error and turn off the output after 5 seconds; |
|
|
| Peak power | 6000VA | 8000VA | 10000VA | 5000VA | 6000VA | 7000VA |
Loaded motor capability
| 2HP | 3HP | 4HP | 1HP | 1HP | 2HP |
|
| Output short circuit protection | Circuit breaker |
| Bypass breaker specifications | 40A |
| Rated battery input voltage | 48V (Minimum starting voltage 44V) |
| Battery voltage range | Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery... settable on LCD screen) |
|
| Power saving mode | Load ≤25W |
| AC charging |
| Battery type | Lead acid or lithium battery |
| Maximum charge current | 60A | 30A |
| Charge current error | ± 5Adc |
| Charge voltage range | 40 –58Vdc | 40 –60Vdc |
| Short circuit protection | Circuit breaker and blown fuse |
| Circuit breaker specifications | 40A |
| Overcharge protection | Alarm and turn off charging after 1 minute |
| PV charging |
| Maximum PV open circuit voltage | 145Vdc |
| PV operating voltage range | 60-145Vdc |
| MPPT voltage range | 60-115Vdc |
| Battery voltage range | 40-60Vdc |
| Maximum output power | 3200W | 4200W | 3200W | 4200W |
| PV charging current range (can be set) | 0-60A | 0-80A | 0-60A | 0-80A |
| Charging short circuit protection | Blown fuse |
| Wiring protection | Reverse polarity protection |
| Certified specifications |
| Certification | CE(EN62040-1) |
| EMC certification level | EN62040-2, C2 |
| Operating temperature range | -15°C to 55°C |
| Storage temperature range | -25°C ~ 60°C |
| Humidity range | 5% to 95% (Conformal coating protection) |
| Noise | ≤60dB |
| Heat dissipation | Forced air cooling, variable speed of fan |
| Communication interface | USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control |
| Size (L*W*D) | 430mm*338mm*126mm |
| Weight (kg) | 11 |