Large induction heater for wind power ACEPOM190

Model
ACEPOM190
Nature of the Manufacturer
Other
Product Category
Place of Origin
City, Province
Overview
Large induction heater for wind power ACEPOM190
Product Details

It consists of induction coil and iron core, which is controlled by control panel and electric cabinet

It can be used for heating large size, such as bearing block, train wheel and other special-shaped workpieces

A workpiece that can be heated several tons (specific heating weight and size of the workpiece)

The distribution of temperature at the same point on the circle is more uniform

Temperature control heating mode: set the desired heating temperature to prevent the workpiece from overheating

Time control heating mode: can be used to heat the workpiece outside the bearing, improve the flexibility of application

The unique design of customization enables rapid and economical production

Equipment structure: rotating heating rod, main control cabinet separation

Equipment load: 5T

Maximum temperature: 480 degrees

Control mode: time control / digital display / temperature control

Equipment electrical parameters: voltage two-phase AC380V + 10%

Rated capacity: 120KVA

Main equipment: heating by column induction coil; increasing magnetic line

It adopts epoxy resin sealed insulation to ensure the insulation performance of the equipment

Suitable workpiece size: inner diameter: 200-1500mm, outer diameter: maximum Phi 2500mm, thickness: maximum 900mm

The workpiece can be heated to 120 degrees in about 60 minutes

Residual magnetic degaussing: less than 1mT (MT)

When the main engine is automatically powered off, the circuit board, the control circuit, the main control element, the SCR are switched off, the thyristor gradually cuts off the power supply and simultaneously completes the demagnetization of the heating workpiece.

Specific operation process:

The main heating rod is rotated to be opened, and the workpiece is sheathed into the heating rod to be penetrated into the inner hole of the workpiece. Select the time control mode or temperature control mode according to their own requirements, and the corresponding set of required time and the heating temperature, start heating, heating to set time or temperature, automatically stop heating heater, and alarm. Take out the iron, lift the workpiece and assemble it in place.

Safety protection: heating host overheating overload and short-circuit protection device, automatic jump off, and high temperature resistant epoxy resin sealed with host line package with the host shell, insulation performance, have adequate security to ensure personal safety.

Working principle: adopting eddy current principle, under the condition of power frequency (50-60Hz), the heater host is used as a transformer with special structure, and a closed magnetic loop is formed by heating the main iron core of the workpiece and the host. At work, the workpiece passes through the heater's magnetic lines of force to produce eddy currents, which are rapidly heated and heated to swell to meet the interference assembly requirements.

Equipment selection:

Dry self cooled induction heater by frequency induction heating device and control parts, manufactured according to the standard IEC439 - 76, the host for the B class insulation shell is made of high strength engineering plastics, wire selection of double glass fiber aluminum flat wire, winding drying varnish with epoxy resin package, pressure test according to IEC standard, stability assessment under the 2000V to power 5min, the insulation resistance should still be greater than 2M. Taking into account the temperature rise of the heated workpiece is much higher than the allowable temperature rise of B insulation, the design adopts other heat insulation measures in addition to the adoption of anti radiation technology measures. The equipment has reliable automatic demagnetization function and conforms to the ZQ33-85 standard.

Equipment with such as AC contactor, thermal relay, intermediate relay, and other types of overheating protection, power-off function, electrical components.