◆ Summary
Pors-TR/TC (B) series integrated thermocouple & RTD are generally used with indicator, recorder, PC to measure temperature of liquid, steam, gas and solid’s surface within range of 0~1800℃, export 4-20mA.
◆ Features Two wire 4-20mA output, high anti-interference;
Save cost for compensation wire and installation of temperature transmitter;
Wide measuring range;
Cold-junction automatic compensation, non-linear calibration circuit;
◆ Standard: The sensors are made complying with standard:
IEC60584, IEC1515, IEC60751, JB/T7391-94
◆ Measuring range and Tolerance
RTD
| Model | Type | Measuring range ℃ | class | Tolerance |
| TRPB | PT100 | -200~500 | A | ±(0.15+0.002|t|) |
| B | ±(0.30+0.005|t|) |
| TRCB | Cu50 | -50~+100 | --- | ±(0.30+0.006|t|) |
| Cu100 |
Thermocouple
| Model | Type | I class | II class |
| Tolerance | Measuring range ℃ | Tolerance | Measuring range ℃ |
| TCK | K | ±1.5℃ | -40~+375 | ±2.5℃ | -40~+333 |
| ±0.004|t| | 375~1000 | ±0.0075|t| | 333~1200 |
| TCN | N | ±1.5℃ | -40~+375 | ±2.5℃ | -40~+333 |
| ±0.004|t| | 375~1000 | ±0.0075|t| | 333~1200 |
| TCE | E | ±1.5℃ | -40~+375 | ±2.5℃ | -40~+333 |
| ±0.004|t| | 375~800 | ±0.0075|t| | 333~900 |
| TCJ | J | ±1.5℃ | -40~+375 | ±2.5℃ | -40~+333 |
| ±0.004|t| | 375~750 | ±0.0075|t| | 333~750 |
| TCT | T | ±0.5℃ | -40~+125 | ±1.0℃ | -40~+133 |
| ±0.004|t| | 125~350 | ±0.0075|t| | 133~350 |
| TCS | S | ±1.0℃ | 0~+1100 | ±1.5℃ | 0~600 |
| ±[1+0.003(t-1100)] | 1100~1600 | ±0.0025|t| | 600~1600 |
Note: t is temperature of the measured medium;
◆ Technical parameters
Power supply: 24V DC ± 10%
Protective class: IP65
Output signal: 4~20mA (2 wire), load: 250ohm, leadwire resistance: 100ohm;
Accuracy: 0.1, 0.2, 0.5 (optional)
working environment
| Field class | Temperature ℃ | Related humidity | Atmospheric pressure |
| Cx1 | -25~+55 | 5~95 | 86~106 |
| Cx2 | -25~+70 |
| Cx3 | -40~+80 |
◆ Connection Mode
◆ Terminal box

◆ Model details