LPS filter cartridges are integrity testable membrane filters specially developed for filtration in vaccines. They are characterized by a unique asymmetric, hydrophilic polyethersulfone membrane, offering high throughputs, low protein adsorption and superior microbiological safety. These filters can remove bacterial and particulate contaminants in vaccine filtration.Features and Benefits● Low protein binding ● Absolute bacteria retention● Long service life and high flow rates Quality● Cartridges produced in a contr......
LPS filter cartridges are integrity testable membrane filters specially developed for filtration in vaccines. They are characterized by a unique asymmetric, hydrophilic polyethersulfone membrane, offering high throughputs, low protein adsorption and superior microbiological safety. These filters can remove bacterial and particulate contaminants in vaccine filtration.Features and Benefits● Low protein binding ● Absolute bacteria retention● Long service life and high flow rates Quality● Cartridges produced in a controlled environment● Manufactured according to ISO9001 certified Quality Management System
Specification
LPS Filter Cartridge for Vaccines
Materials of Construction |
Membrane | Single Layer Hydrophilic PES |
Support | PP |
Core, Cage and Drainage | PP |
End Caps | PP (222/226 with encapsulated stainless steel reinforcing ring) |
O-rings/Gasket | Silicone/EPDM/FKM |
Sealing technology | Thermal Bonding, No Adhesives |
Dimensions |
Diameter | Φ68 |
Length | 5 inch, 10 inch, 20 inch, 30 inch, 40 inch |
Filtration Area, ft2 |
≥ 5.7 per 10-inch cartridges |
Pore Size, μm |
0.1, 0.22, 0.45, 0.65, 0.8, 1.2, 3.0 |
Maximum Differential Pressure |
Forward: 4.2 bar @ 23 ℃; 1.5 bar @ 85 ℃ |
Integrity Test-water bubble point at 23 ℃ |
0.1 μm | ≥ 3800 mbar (58 psig) |
0.22 μm | ≥ 3400 mbar (49 psig) |
0.45 μm | ≥ 2300 mbar (33 psig) |
0.65 μm | ≥ 1300 mbar (19 psig) |
0.8 μm | ≥ 600 mbar (8 psig) |
1.2 μm | ≥ 400 mbar (6 psig) |
Bacterial Retention (for 0.1 μm & 0.22 μm only) |
Passed the bacterial challenge testing using Brevundimonas diminuta(ATCC19146) at a minimum challenge concentration of 1 x 107 CFU/cm2. |
Extractables, per 10-inch cartridge |
≤ 50 mg after 24-h soak in water |
Effluent Particle Level |
Meets the requirements of Chinese Pharmacopoeia 2010, Volume Ⅱ, appendix Ⅸ C. |
Non-Fiber Releasing |
Meets the criteria for a “non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6). |
Toxicity |
Component materials meet GB/T 14233.2<2005>of Chinese National Standard for Safety Tests. |
TOC |
< 500 ppb after a water flush of 60 liters per 10-inch cartridge |
Multiple Sterilization Cycles |
15 steam-in-place sterilization or autoclave cycles of 30 min at 123℃ |
Oxidizable Substances |
Meets the criteria of Chinese Pharmacopoeia 2010, volume Ⅱ for purified water. |
Bacterial Endotoxins |
< 0.25 EU/ml as determined by the LAL test |