LPT filter cartridges are characterized by permanently hydrophobic PTFE membrane, specially developed for sterile filtration of Active Pharmaceutical Ingredients production. They are integrity testable, providing high throughputs, broad chemical compatibility and high flow rates. Due to their hydrophobic characteristic, they must be pre-wetted with ethanol or IPA before the filtration of aqueous solutions.Features and Benefits● Broad chemical compatibility● High throughputs and superior flow rates● 99% integrity t......
LPT filter cartridges are characterized by permanently hydrophobic PTFE membrane, specially developed for sterile filtration of Active Pharmaceutical Ingredients production. They are integrity testable, providing high throughputs, broad chemical compatibility and high flow rates. Due to their hydrophobic characteristic, they must be pre-wetted with ethanol or IPA before the filtration of aqueous solutions.Features and Benefits● Broad chemical compatibility● High throughputs and superior flow rates● 99% integrity testable prior to releaseQuality● Cartridges produced in a controlled environment● Manufactured according to ISO9001 certified Quality Management System
Specification
LPT Filter Cartridge for Active Pharmaceutical Ingredients
Materials of Construction |
Membrane | Polytetrafluoroethylene (PTFE) |
Support | PP |
Core, Cage and Drainage | PP |
End Caps | PP (222/226 with encapsulated stainless steel reinforcing ring) |
O-rings/Gasket | EPDM/FKM/E-FKM/Silicone |
Sealing Technology | Thermal Bonding, No Adhesives |
Dimensions |
Diameter | Φ68 |
Length | 5 inch, 10 inch, 20 inch, 30 inch, 40 inch |
Filtration Area, ft2 |
≥ 5.8 per 10-inch element |
Pore Size, μm |
0.05, 0.1, 0.22, 0.45, 1.0, 3.0, 5.0, 10 |
Maximum Differential Pressure |
Forward: 4.2 bar @ 23 ℃; 1.5 bar @ 85 ℃ |
Integrity Test-60/40% IPA/water bubble point at 23 ℃ |
0.1 μm | ≥ 1200 mbar |
0.22 μm | ≥ 900 mbar |
0.45 μm | ≥ 600 mbar |
Bacterial Retention (for 0.05, 0.1 and 0.22 μm only) |
Passed the bacterial challenge testing using Brevundimonas diminuta(ATCC19146) at a minimum challenge concentration of 1 x 107 CFU/cm2. |
Extractables, per 10-inch cartridge |
≤ 50 mg after 24-h soak in water |
Effluent Particle Level |
Meets the requirements of Chinese Pharmacopoeia 2010, Volume Ⅱ, appendix Ⅸ C. |
Non-Fiber Releasing |
Meets the criteria for a “non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6). |
Toxicity |
Component materials meet GB/T 14233.2<2005>of Chinese National Standard for Safety Tests. |
TOC |
< 500 ppb after a water flush of 60 liters per 10-inch cartridge |
Multiple Sterilization Cycles |
15 steam-in-place sterilization or autoclave cycles of 30 min at 123℃ |
Oxidizable Substances |
Meets the criteria of Chinese Pharmacopoeia 2010, volume Ⅱ for purified water. |
Bacterial Endotoxins |
< 0.25 EU/ml as determined by the LAL test |