LPPF filter cartridges are constructed of multilayer polypropylene, featuring high flow rates and high dirt holding capacity. They are ideal for removing particles and gel polymer for ophthalmic solutions. In addition, these filters can be personalized according to your specific processes, such as particle size and length, improving filtration efficiency and reducing filtration costs.Features and Benefits● Superior dirt-holding capacity● Reliable retention of particulates● Broad chemical compatibilityQuality● Cartr......
LPPF filter cartridges are constructed of multilayer polypropylene, featuring high flow rates and high dirt holding capacity. They are ideal for removing particles and gel polymer for ophthalmic solutions. In addition, these filters can be personalized according to your specific processes, such as particle size and length, improving filtration efficiency and reducing filtration costs.Features and Benefits● Superior dirt-holding capacity● Reliable retention of particulates● Broad chemical compatibilityQuality● Cartridges produced in a controlled environment● Manufactured according to ISO9001 certified Quality Management System
Specification
LPPF Multi-layer Filter Cartridge for Ophthalmic Solutions
Materials of Construction |
Filter Media | Multi-layer PP |
Support | PP |
Core, Cage and Drainage | PP |
End Caps | PP |
O-rings/Gasket | Silicone/EPDM/FKM/E-FKM |
Sealing Technology | Thermal Bonding, No Adhesives |
Dimensions |
Diameter | Φ68 |
Length | 5 inch, 10 inch, 20 inch, 30 inch, 40 inch |
Filtration Area, ft2 |
2.1~3.2 per 10-inch element |
Pore Size, μm |
0.5, 1.0, 3.0, 5.0, 10, 20 |
Maximum Differential Pressure |
Forward: 4.2 bar @ 23 ℃; 1.5 bar @ 85 ℃ |
Particle Removal Efficiency (%) |
≥ 90 |
Extractables, per 10-inch cartridge |
≤ 50 mg after 24-h soak in water |
Toxicity |
Component materials meet GB/T 14233.2<2005>of Chinese National Standard for Safety Tests. |
TOC |
< 500 ppb after a water flush of 60 liters per 10-inch cartridge |
Sterilization |
Support steam-in-place sterilization or autoclave at 123℃ |
Oxidizable Substances |
Meets the criteria of Chinese Pharmacopoeia 2010, volume Ⅱ for purified water. |
Bacterial Endotoxins |
< 0.25 EU/ml as determined by the LAL test |