RG 6U CATV Shielded Cable
Standards
1. Reference Standard: IEC 61196, BS EN 50117, UL13, UL444
2. Operating Temperature: 20℃~75℃
3. Impedance (ohms): 75.0
4. Nom. Capacitance: 52pF/m
5. Min. SRL (dB, 5~6000MHz): 23
Applications
Drop cable for interior application
Characteristics
1. Max. Operating Temp of Conductor. 75℃
2. Conductor with high quality copper clad steel
3. Insulation material for high-quality PE, anti-aging, low-temperature resistance, anti-chemical corrosion, non-toxic and other characteristics can be customized.
4. Sheath material for high-quality PVC, anti-aging, wear resistance, waterproof, anti-chemical corrosion, non-toxic and other characteristics can be customized.
5. Shielded with aluminum foil and aluminum high-density weaving, effectively blocking the external electromagnetic interference.
| Conductor | Insulation | Shield | Sheath | Max. Conductor DCR at 20℃(ohm/km) | Nom. Velocity of Propagation (%) |
| Material | Dia. | AWG | Material | Dia. | Al-foil | Braid | Material | Thickness (mm) | O.D. |
| (mm) | (mm) | Material | Coverage | Nom. | Min. | (mm) |
| CCS | 1.02 | 18 | Foam PE | 4.75 | Al-foil | AL | 60% | PVC | 0.70 | 0.50 | 6.80 | 100 | 82 |
| Electrical Characteristics |
| Frequency | Attenuation |
| (MHz) | (dB/100m) |
| 1 | 1.21 |
| 10 | 2.16 |
| 50 | 4.62 |
| 100 | 6.30 |
| 200 | 8.66 |
| 400 | 12.23 |
| 700 | 16.56 |
| 900 | 18.99 |
| 1000 | 20.04 |
| 1750 | 29.00 |
| 2150 | 32.50 |
| 2200 | 33.00 |
| 3000 | 39.00 |