Standards
1. Reference Standard: IEC 61196, BS EN 50117, UL13, UL444
2. Rated Temperature: 70℃
Applications
Drop cable for interior application
Characteristics
1. Max. Operating Temp of Conductor. 70℃
2. Conductor with high quality copper, low signal transmission attenuation
3.Insulation material for high-quality PE, anti-aging, low-temperature resistance, anti-chemical corrosion, non-toxic and other characteristics can be customized.
4. Sheath material for high-quality PVC, anti-aging, wear resistance, waterproof, anti-chemical corrosion, non-toxic and other characteristics can be customized.
5. Shielded with aluminum foil and tinned copper high-density weaving, effectively blocking the external electromagnetic interference.
6. Impedance (ohms): 75.0
7. Nom. Capacitance: 53.2pF/m
8. Min. SRL (dB, 5~400MHz): 20
| Model | Conductor | Insulation | Shield | Sheath | Max. Conductor DCR at 20℃(ohm/km) | Nom. Velocity of Propagation (%) |
| Material | Dia. | AWG | Material | Dia. | Al-foil | Braid | Material | Thickness (mm) | O.D. |
| (mm) | (mm) | Material | Coverage | Nom. | Min. | (mm) |
| BC+TC (95%) | BC | 1.02 | 18 | Foam PE | 4.6 | Al-foil | TC | 95% | PVC | 0.85 | 0.70 | 6.90 | 24.5 | 80 |
| Electrical Characteristics |
| Frequency | Attenuation |
| (MHz) | (dB/100m) |
| 5 | 2.70 |
| 55 | 5.30 |
| 211 | 10.12 |
| 250 | 11.11 |
| 270 | 11.61 |
| 300 | 12.24 |
| 330 | 12.86 |
| 350 | 13.25 |
| 400 | 14.22 |
| 450 | 15.41 |
| 500 | 15.97 |
| 550 | 16.82 |
| 600 | 17.71 |
| 750 | 19.8 |
| 870 | 21.4 |
| 1000 | 23.12 |