Standards
1. Reference Standard: IEC 61196, BS EN 50117, UL13, UL444
2. Rated Temperature: 70℃
3. Rated Voltage: 300V
Applications
Drop cable for interior application
Characteristics
1. Max. Operating Temp of Conductor. 70℃
2. Conductor with high quality copper, low signal transmission attenuation
3. RG59 & RS-485 insulation material for high-quality PE,anti-aging, low-temperature resistance, anti-chemical corrosion, non-toxic and other characteristics can be customized.
4. Power cable insulation material for high-quality PVC, anti-aging, low-temperature resistance, anti-chemical corrosion, non-toxic and other characteristics can be customized.
5. Sheath material for high-quality PVC, anti-aging, wear resistance, waterproof, anti-chemical corrosion, non-toxic and other characteristics can be customized.
6. RS-485 is shielded with aluminum foil, effectively blocking the external electromagnetic interference.
7. Impedance (ohms):50.0
| Structure | Conductor | Insulation | Shield | Sheath | Outer Sheath (mm) | Max. Conductor DCR at 20℃(ohm/km) | Insulation Resistance @70℃ (MΩ/KM) |
| MTRL | Dia. | AWG | MTRL | Dia. | Al-foil | Braid | MTRL | Nom Thickness (mm) | O.D. |
| (mm) | (mm) | MTRL | Coverage | (mm) |
| RG59 | BC | 0.58 | 23 | Solid PE | 3.6 | | BC | 80% | PVC | 0.95 | 5.80 | 13.80 | 70.0 | 0.013-0.014 |
| Power | BC | 16/0.2 | 20 | PVC | 1.90 | | | | PVC | 0.60 | 5.00 | 39.0 |
| RS-485 | TC | 7/0.20 | 24 | Solid PE | 1.7 | Al-foil | | | PVC | 0.60 | 4.80 | 92.3 |