Standards
1. Reference Standard: IEC 61196, BS EN 50117, UL13, UL444
2. Rated Temperature: 70℃
Applications
Drop cable for interior application
Characteristics
1. Max. Operating Temp of Conductor. 70℃
2. Conductor with high quality copper, low signal transmission attenuation
3. Insulation material for high-quality PE, anti-aging, low-temperature resistance, anti-chemical corrosion, non-toxic and other characteristics can be customized.
4. Sheath material for high-quality PVC, anti-aging, wear resistance, waterproof, anti-chemical corrosion, non-toxic and other characteristics can be customized.
5. Shielded with aluminum foil and copper clad aluminum high-density weaving, effectively blocking the external electromagnetic interference.
6. Impedance (ohms):75.0
7. Nom. Capacitance: 67 pF/m
8. Min. SRL (dB, 5~400MHz): 31
| Conductor | Insulation | Shield | Inner Sheath | Max. Conductor DCR at 20℃(ohm/km) | Nom. Velocity of Propagation (%) |
| Material | Dia. | Material | Dia. | Al-foil | Braid | Material | Thickness (mm) | O.D. |
| (mm) | (mm) | Material | Coverage | Nom. | Min. | (mm) |
| BC | 0.20 | PE | 3.60 | Al-foil | CCA | 80% | PVC | 0.90 | 0.70 | 5.80 | 92.3 | 66 |
| Electrical Characteristics |
| Frequency | Attenuation |
| (MHz) | (dB/100m) |
| 50 | 7.50 |
| 100 | 10.90 |
| 200 | 15.80 |
| 400 | 22.90 |
| 500 | 25.80 |
| 600 | 28.70 |
| 860 | 34.80 |
| 1000 | 38.00 |