WDZB-SYWY75 LSOH 75Ω Coaxial Cable
Standards
Reference Standard: SJ/T11138.3-1997, GY/T135-1998
Min. bending radius: 35mm (indoor installation) , 70mm (outdoor installation)
Operating temperature: -15 ° C to 70 ° C
Applications
As a physical foam polyethylene insulated coaxial cable, it is suitable for 1GHz and the following closed-circuit television system, shared antenna television system, cable television system as branch lines, subscriber lines and other electronic devices.
Characteristics
1. Conductor with high purity oxygen-free copper, lower attenuation impedance, conduction is more excellent
2. Double 99% covered aluminum foil and polyester film shield, fully isolated EMI / RFI and other clutter signal interference
3. Double-layer high-density tinned copper braid shield, to strengthen the isolation EMI / RFI and other clutter interference
4. Nitrogen injection foam polyethylene insulation, 75 ohm characteristic impedance, bandwidth up to 1000MHz
5. Halogen-free low smoke flame-retardant polyolefin sheathed, wear-resistant, anti-interference, more flexible, environmentally friendly materials, in line with ROHS standards
6. 200m / 300m per roll or custom length
| Parameter |
| Model | Inner Conductor (NO./mm) | Insulation | Braided Shield | Sheath | Package (m) |
| Thickness (mm) | O.D (mm) | Specification | Ref. Density | Thickness (mm) | O.D. (mm) |
| SYWY75-5 | 1/1.02 | 1.2 | 4.8±0.20 | 64 | 40% | 0.88 | 7.2±0.30 | 200/300 |
| 96 | 60% |
| 128 | 70% |
| SYWY75-7 | 1/1.66 | 2 | 7.25±0.25 | 96 | 45% | 1.05 | 10.3±0.30 |
| 128 | 55% |
| 144 | 60% |
| 176 | 70% |
| SYWY75-9 | 1/2.15 | 2 | 9.0±0.25 | 96 | 40% | 1.15 | 12.3±0.30 |
| 128 | 50% |
| 160 | 60% |
| 192 | 75% |
| SYWY75-12 | 1/2.77 | 3.2 | 11.5±0.25 | 128 | 40% | 1.3 | 15.1±0.30 |
| 160 | 50% |
| 192 | 70% |
| Parameter |
| Item | Core Dielectric | Insulation Resistance | Sheath Dielectric | Characteristic Impedance | Attenuation at 20℃ | Return Loss | Shield Attenuation |
| Test | 40-60Hz,1min | 500V(DC) 20℃ | 40-60Hz Spark Test | 200MHz |
| Unit | KV | MΩ.km | KV | Ω | dB/100M | dB | dB |
| SYWY-75-5 | ≥1.2 | ≥5000 | ≥3.0 | 75±3 | 5MHz≤2.2 | Above 300MHz:≥18 Below 300MHz ≥20 | 5MHz≥60 |
| 50MHz≤4.8 | 50MHz≥60 |
| 200MHz≤9.7 | 200MHz≥70 |
| 550MHz≤16.8 | 550MHz≥70 |
| 800MHz≤20.3 | 800MHz≥70 |
| 1000MHz≤24.2 | |
| SYWY-75-7 | ≥1.0 | ≥5000 | ≥5.0 | 75±2.5 | 5MHz≤1.5 | 5MHz≥60 |
| 50MHz≤3.2 | 50MHz≥60 |
| 200MHz≤6.4 | 200MHz≥70 |
| 550MHz≤10.7 | 500MHz≥70 |
| 800MHz≤13 | 800MHz≥70 |
| 1000MHz≤15.1 | |
| SYWY-75-9 | ≥1.0 | ≥5000 | ≥3.0 | 75±2.5 | 5MHz≤1.2 | 5MHz≥60 |
| 50MHz≤2.4 | 50MHz≥60 |
| 200MHz≤5.0 | 200MHz≥70 |
| 550MHz≤8.5 | 500MHz≥70 |
| 800MHz≤10.4 | 800MHz≥70 |
| 1000MHz≤19.1 | |
| SYWY-75-12 | ≥1.6 | ≥5000 | ≥5.0 | 75±2 | 5MHz≤0.7 | 5MHz≥60 |
| 50MHz≤1.9 | 50MHz≥60 |
| 200MHz≤3.9 | 200MHz≥70 |
| 550MHz≤6.7 | 500MHz≥70 |
| 800MHz≤8.2 | 800MHz≥70 |
| 1000MHz≤9.5 | |