Standards
1. Reference Standard: JB/T 10261-2001
2. Rated Voltage: 300/500V,450/750V
3. Operating Temperature: -60℃-105℃
Applications
Applicable to aircraft low-voltage lines, highway test equipment and inductive coil line (electronic system, sense coil line).
Characteristics
1. Multi-stranded tinned copper wire, strong corrosion resistance
2. Special heat-resistant PVC insulation, heat-resistance, anti-aging
3. Jacket with high quality nylon material with wear-resistant, waterproof, cold-resistance, anti-corrosion and other characteristics
4. In the relative humidity of 98%, cable can be used normally
5. Bending radius should not be less than 6 times the finished diameter
6. Shielded wire can be customized.
| Section Area | Conductor | Insulation Thickness | Sheath Thickness | O.D. | Max. Conductor Resistance at 20℃ |
| Unscreened | Screened |
| mm2 | No./mm | mm | mm | mm | mm | Ω/km |
| 0.3 | 16/0.15 | 0.35 | 0.12 | 1.7 | 2.2 | 71.2 |
| 0.5 | 28/0.15 | 0.35 | 0.12 | 2 | 2.5 | 40.1 |
| 0.75 | 42/0.15 | 0.35 | 0.12 | 2.1 | 2.6 | 26.7 |
| 1 | 32/0.20 | 0.35 | 0.14 | 2.3 | 2.7 | 20 |
| 1.5 | 48/0.20 | 0.4 | 0.14 | 2.7 | 3.2 | 13.7 |
| 2.5 | 49/0.25 | 0.5 | 0.14 | 3.6 | 4.1 | 8.21 |
| 4 | 49/0.32 | 0.6 | 0.16 | 4.4 | 4.9 | 5.09 |
| 6 | 84/0.30 | 0.6 | 0.16 | 5.1 | 5.6 | 3.39 |
| 10 | 19*7/0.32 | 0.9 | 0.2 | 6.6 | 7.1 | 1.95 |
| 16 | 19*7/0.39 | 1 | 0.2 | 8.3 | 8.9 | 1.24 |