Standards
Standard: JB / T 8734-2012
Operating temperature: -15 ° C to 70 ° C
Applications
It is used for transmission of low frequency audio signal, connection of amplifier and speaker system. Usually used in shopping malls, public venues, buildings, residential interior for background music broadcast, call broadcast and disaster broadcast.
Characteristics
1. The cable long-term allowable operating temperature does not exceed 70 ℃.
2. Cable laying temperature should not be less than 0 ℃.
3. Allowable bending radius: not less than 4 times the cable diameter.
4. Jacket with high quality PVC material, anti-aging, wear resistance.
5. Flame retardant, fire resistance, halogen-free low smoke, waterproof, shielded and other characteristics can be customized.
| Specs | Conductor No./mm | Insulation Thickness (mm) | Approx. O.D. (mm) | Screen | Max. Conductor Resistance at 20℃ |
| Ω/km |
| CU | TC |
| 2×0.75 | 24/0.20 | 0.6 | 1 | 5.7 | 7.1 | 26 |
| 2×1.0 | 32/0.20 | 0.6 | 1 | 6.9 | 7.3 | 19.2 |
| 2×1.5 | 30/0.25 | 0.7 | 1 | 7.7 | 8.1 | 13.3 |
| 2×2.0 | 40/0.25 | 0.7 | 1 | 8.7 | 9.1 | 9.79 |
| 2×2.5 | 50/0.25 | 0.8 | 1.2 | 9.5 | 9.9 | 7.98 |
| 2×4 | 81/0.25 | 0.8 | 1.3 | 10.9 | 11.3 | 4.95 |
| 2×6 | 84/0.30 | 0.8 | 1.3 | 12.3 | 12.7 | 3.3 |