SIC tube heat exchanger, consisting of corrosion-resistant tube sheets and silicon carbide tubes, is the best solution for the most demanding corrosive conditions.
SIC tubular heat exchangers use heat-resistant tubes made of corrosion-resistant silicon carbide that are ideal for heating, cooling and condensing chemically corrosive process media. Typical applications include: bromine, sulfuric acid, hydrofluoric acid, nitric acid, hydrochloric acid and other acids; bases; halogenated compounds; salt solutions and organic compounds.
Reinforced double tube plate [steel lined F4 or steel lined PFA] SIC heat exchange
● Test each heat exchange tube under pressure of 185 Bar before installation
● Heat exchanger housing diameter range from DN100 to DN600
● The standard length of the heat exchange tube is 1000 to 3000mm
● Heat exchange area is 1 to 40 square
● Heat exchange tube diameter is 14mm and 19mm
● Horizontal or vertical installation
● steel lining F4 Applicable temperature range -19℃ to 120℃
● steel lining PFA Applicable temperature range -19℃ to 120℃
● Applicable pressure range -0.1Mpa to 0.6Mpa
● Comply with CE, ATEX, FDA
● Double tubeSheet deSign
It is possible to separate the process fluid and the service fluid with a separation chamber, so that in case of o-ring leaking no mix will occur between the two fluids.
Red column must be filled Click to download
Design requests of SIC |
Device number | | |
| | Jacket | in side of heat exchanger |
Fluid name / component | | | |
Total flow | kg/h | | |
Gas flow | kg/h | | |
Liquid flow | kg/h | | |
Non condensable material flow | kg/h | | |
Tempreture ( In / Out) | °C | | | | |
Freezing point / Boiling point | °C | | |
Density | kg/m3 | | |
Viscosity | cP | | |
Gas molecular weigh | g/mol | | |
Molecular weight of non condensates | g/mol | | |
Specific heat | cal/g/k | | |
Thermal conductivity | kcal/m/K/h | | |
latent heat | kcal/kg | | |
Inlet pressure (absolute pressure) | Mpa | | | | |
Current Speed | m/s | | |
Pressure drop | bar | | |
Fouling coefficient | kcal/h/m2/°C | | |
Heat exchange capacity | kcal/h | |
Heat transfer coefficient(clean / dirty / service side) | kcal/h/m2/°C | |
Corrected logarithmic mean temperature difference | °C | |
Heat exchange area (required / provided) | m2 | |
Equipment selection data |
Design temperature | °C | | |
Design pressure | barg | | |
Test pressure | barg | | |
Process number | | | |
Inlet pipe diameter | mm | | |
Outlet pipe diameter | mm | | |
Material | | | |
Weight (empty / full water) | kg | |
Installation method | | |
SIC tubular heat exchangers use heat-resistant tubes made of corrosion-resistant silicon carbide that are ideal for heating, cooling and condensing chemically corrosive process media. Typical applications include: bromine, sulfuric acid, hydrofluoric acid, nitric acid, hydrochloric acid and other acids; bases; halogenated compounds; salt solutions and organic compounds.