Fermenter:
Fermentation tanks provide a sterile and pollution-free fermentation process for dairy products, beverages, bioengineering, pharmaceuticals, fine-line chemical industry and other industries. The fermentation tanks use an aseptic system to avoid and prevent microbial pollution in the air and greatly extend The shelf life of your product and the purity of the product, we specially designed and installed a sterile breathing vent or a sterile positive pressure fermentation system on the tank. The tank body is provided with a Milo plate or a labyrinth jacket, which can be heated or cooled by circulating heating or cooling medium.
Enzymatic hydrolysis tank:
Enzymatic hydrolysis tank, also known as enzymatic hydrolysis reactor and biological enzymatic hydrolysis reactor, provides the temperature required for enzymatic hydrolysis, adjusts the PH value and provides stirring and mixing to keep the enzyme activated and play the role of enzyme, accelerate the improvement and complete the biological reaction process. Stainless steel container. Biological enzymolysis technology is to use a suitable biological catalyst, that is, a biological enzyme, to decompose substances, accelerate the process of decomposition and conversion, and turn them into substances that are beneficial to use and the purpose that experiments or production processes want to accomplish. Widely used in the fields of protein enzymatic hydrolysis and conversion, biodegradation of wastewater, etc.
Technical parameters of fermentation tank / enzymolysis tank
Nominal volume | 100L | 300L | 500L | 1000L | 2000L | 3000L | 5000L | 10000L |
Inner diameter size(mm) | 500 | 800 | 900 | 1100 | 1400 | 1500 | 1800 | 2100 |
Heat exchange area (m2) | 0.9 | 2.0 | 2.7 | 4.5 | 7.5 | 10.0 | 13.5 | 22 |
Stirring power (KW) | 0.55 | 0.75 | 1.5 | 3.0 | 4.0 | 5.5 | 7.5 | 11.0 |
Speed (r / m) | Fixed speed or frequency control |
Stirring form | Design and manufacture according to material properties |
Working pressure (Mpa) | Design and manufacture according to technological conditions |
Working temperature ℃ | 0-142° |
Jacket heating / cooling medium | Steam / cooling water |
Applicable PH | 2-12 |
Insulation Materials | Polyurethane |
Nozzle configuration | Can be designed as needed under the conditions |
Tank material | SUS304/316L or other anti-corrosion stainless steel materials |
Container categories | Atmospheric pressure / Class I |