Welcome Customer !

Membership

HENAN CHICHENG ELECTRIC CO., LTD
Free Member ·1YRS
,
Other

Main Products: 气体探测仪

Xwboo>Products

HENAN CHICHENG ELECTRIC CO., LTDFree·1YRS

  • E-mail

    sales@cce-china.com

  • Phone

    +86-371-86621122

  • Address

    17th Floor R & D NO.5 Building, National University Science Technology Park, 1 Changchun Road, Zhengzhou,Henan Province, China 450001

Contact Now

QB2000F Gas Detector

Model
Nature of the Manufacturer
Other
Product Category
Fixed Gas Detector
Place of Origin
City, Province
Overview
Gas: Single Gas Like Combustion Gas、Toxic Gas、O2 And So On.
Product Details

QB2000F is a 4-20mA/RS485 Signal Wall-Mounted Fixed Oxygen Sensor O2 Gas Detector Alarm Monitor QB2000F which designed to monitor the gas leakage in the working environment continuously by adopting imported catalytic combustion or electro-chemical gas sensors. The detector has excellent sensibility, quite good accuracy, linearity and receptivity; Big English LCD displays the real-time concentration of the leakage gas. With 2 relay output, once the concentration exceed the preset alarm point (threshold), it will start the acoustic-optical alarm and it can drive the external equipment like exhaust fans; Through 4-20mA signal output, it can be directly connected into the factory DCS system, through RS4845 signal output, it can be connected with factory’s principle computer.

Application:

It is widely applied to coal, petroleum, electrochemical, phamaceutical, metallurgy, tabacco, railway, tunnel, etc.



Beneficios

  • Adopts advanced 16 digit ultra-low power consumption embedded micro controller

  • 128*64 dot matrix ultra-large liquid-crystal display

  • Replaceable sensor module design

  • Automatic calibrating to ensure the detecting accuracy

  • Password management and IR remote function

  • The optional internal battery backup can work continuously for 24 hours

Technical Data

Model

QB2000F

Detected Gas

Multi gas(Toxic gas combustible gas or oxygenco2 up to 4 gases)

Accuracy

3%F.S

Response Time

T90<30s

Operating temperature

-20℃~+50℃

Humidity

<90%RH no condensation

Display

LCD indicates real time and system stategas concentrationhistorical data

Alarm

Audible and visual >=100dB the higher of buzz frequencythe higher gas concentration is

Alarm

Audible visual

Operation

IR remote control

Sampling method


Natural diffusion

Output signal

RS485 or GPRS optional

Net Weight

3790g(including battery)

Sampling method

Natural diffusion

Anti-explosion Class

Ex d IICT6 Gb


Application

Similar Product Recommend