♦ Working temperature: 10℃~40℃
♦ Relative humidity: ≤85%
♦ Power: DC 3V(2 AAA battery)
♦ Size: 59.4mm×37.8mm×43.3mm(L×W×H)
♦ Net weight: 125g
♦ Resolution : 0.1℃
♦ Measurement range: optical surface mode: 0℃~60℃
♦ Consumed power: ≤150mw
♦ Respond: ≤0.5s
♦ Measuring distance: 3cm~5cm
♦ Automatically off without operation in 15 seconds.
Product Appearance
Thetemperature meter consists of the infrared probe, main circuit board, LCD display and enclosure.
Operation
The correct operation is the key to measure the accuracy, otherwise it may cause the measurement error. Please follow the following instructions
1)Press the button to turn on the device. After 1 second the full screen is lighten , “—℃” or "-- ℉" will be displayed, which indicates that the temperature meter is ready to
work. Press the button 1 second to start work.
2)When the temperature difference is big between the temperature meter storage place and its working place, the temperature meter should be taken out 20 minutes before it
is used to detect optical surface temperature.
3)Do not use the product under the direct sunlight.
4)It is recommended to measure 3 times per time, and take the highest temperature as reference
Setting
The default setting parameter can be modified. The factory settings have been made for different sales market before delivery, it is not suggested to modify the setting parameters.
Please follow the steps below if it is a must to modify.
Temperature unit---F1
The temperature unit is ℃ and ℉.
Setting ways: In the standby state, the operator presses the "Set" button for more than 2 seconds, and the display screen shows "F1";Then Select“-”to choose(℃); Select “+” to
choose (°F);
Note: The factory default is ℃
Alarm temperature setting---F2
In the standby state, the operator presses the "Set" button for more than 2 seconds, F1 is displayed, then press the "Set" button once more, F2 is shown; then if "+" button is
pressed once, the alarm temperature increases by 0.1℃; while "-" button is pressed once, the alarm temperature to be decreased by 0.1℃.
Temperature mode
he object optical surface temperature range: 0℃~60℃.
Note: The "object optical surface temperature" mode is only used for test the external temperature. (Such as object optical surface temperature)
The whole offset value setting—F3
The measurement deviation adjustment: In the standby state, the user presses the "Set" button for more than 2 seconds, F1 is displayed, then presses the "Set" button three
times more, F3 is shown; then if "+" button is pressed once, the alarm temperature increases by 0.1℃; while "-" button is pressed once, the alarm temperature to be decreased by
0.1℃.
Note: The factory default is +0.0℃.
Buzzer Switch setting---F4
In the standby state, the user presses the "Set" button for more than 2 seconds, F1 is displayed, then presses the "Set" button four times more, F4 is shown; then if "+" button is
pressed once, the buzzer is on; while "-" button is pressed, the buzzer will be off.
Note:The factory buzzer default is on.
Exit
In F4 mode, if the user can press the "Setting" button once, the screen is off and the device exits the setting automatically.
Data Memory
Every test data will be recorded automatically after the test, 32pcs data records can be saved. If users want to check these data, please follow the steps as below.
In the standby state, when the "-" button is pressed, the penultimate data will be displayed, the other saved datas can deduce the rest from this. Without operation in 5 seconds,
the lastest data will be displayed.
Data Elimination
In the standby state, the operator presses "+" button for 5 seconds, all the saved datas will be eliminated.
23
Battery Replacement
1)Thetemperature meter is equipped with 2pcs AAA Batteries. It indicates lower power when the symbol of battery flashes in the screen. Please replace the battery.
2)Open the battery shell and replace it. Pay more attention on locating it on the correct poles.
3)Rechargeable Batteries are not suitable for the device and is forbidden to use.
If it’s not in use for long period, please take off the battery to prevent the battery leakage
4)The instrument with batteries must be disposed in accordance with the local applicable regulations, and it must not be thrown into domestic garbage, to avoid causing
irreversible pollution.
Storage and Delivery
The device in well package is supposed to be stored indoor ,where it’s 20℃~50℃,relative humidity less than 80%, and no corrosive gas exits. During delivery, no dropping, no
pressing heavily, no step is allowed and please keep package in the same way as the sign indicates.
Daily Maintenance
No maintenance is required under normal conditions, when cases as below appears, please follow the tips.
1 ). Stain and dirty on the optical surface of the device:Please remove the stain by use of a clean soft cloth moistened with water, or by use of a cotton stick with medical alcohol
which have also sterilization and disinfection. Pay attention that too much water or alcohol is harmful to the circuit board, please don’t get the cloth or stick with much water or
alcohol.
2).Stained and dirty inside the temperature meter: The sensor inside the device is the core part. Do not touch or press it by hand or other items, because that will effect the
accuracy. If it’s stained, please try a cotton stick with 95% alcohol without water.
Note: 75% alcohol is not allowed to be used to clean the sensor, water trace may left on it.
Store: Keep the device in the place where it’s dry, cool, no direct sunlight and clean. the temperature between -20℃ and 55℃,and relative humidity less than 80%.
Attentions
1)Please follow the instructions about how to use and keep it.
2)Keep it away from electric shock.
3)Do not drop or crack it, or the temperature meter would be damaged.
4)No application with EMI.
5)Batteries can not be recharged and can not be dropped in the fire. Put the battery into the recovery places. Incorrect batteries would cause fire or explosion.
6)Please take off the battery when it’s in no use for long period.
7)The temperature meter can not be soaked in water or exposed to direct sunlight.
Warranty and After-Sale Service
One year warranty after the device is sold
Note: The damage caused by abnormal operation or dis-assembly is not counted in warranty range.