name: Fluorine lined valve J41F46Type: J41F46Presure: 1.0~2.5MPaSpecifications: DN15~DN350material: Full liner

Product description
Fluorine of closing of the valve opening and closing parts are plug shaped valve, sealing surface flat or cone, the valve flap along the center line of the fluid for linear motion. The valve stem movement form, the lifting rod type, also has the lifting and rotating pole type (the hand wheel and the valve stem rotates together, the nut is arranged on the valve body). Only applicable to fully open and fully closed, does not allow for adjustment and throttle.
Main connection and dimensions(PN10)
nominal diameter
| Main connection dimensions and connection dimensions |
Body connecting dimensions | Flange connection size |
L | D0 | H | D | D1 | D2 | b | f | Z-Фd |
15 | 130 | 100 | 260 | 95 | 65 | 45 | 14 | 2 | 4-Ф14 |
20 | 150 | 100 | 265 | 105 | 75 | 55 | 16 | 2 | 4-Ф14 |
25 | 160 | 120 | 270 | 115 | 85 | 65 | 16 | 2 | 4-Ф14 |
32 | 180 | 140 | 285 | 135 | 100 | 78 | 18 | 2 | 4-Ф18 |
40 | 200 | 140 | 315 | 145 | 110 | 85 | 18 | 3 | 4-Ф18 |
50 | 230 | 160 | 330 | 160 | 125 | 100 | 20 | 3 | 4-Ф18 |
65 | 290 | 180 | 395 | 180 | 145 | 120 | 20 | 3 | 4-Ф18 |
80 | 310 | 240 | 445 | 195 | 160 | 135 | 22 | 3 | 8-Ф18 |
100 | 350 | 240 | 490 | 215 | 180 | 155 | 22 | 3 | 8-Ф18 |
125 | 400 | 280 | 555 | 245 | 210 | 185 | 24 | 3 | 8-Ф18 |
150 | 480 | 320 | 645 | 280 | 240 | 210 | 24 | 3 | 8-Ф23 |
200 | 495 | 360 | 765 | 335 | 295 | 265 | 26 | 3 | 8-Ф23 |
250 | 622 | 400 | 805 | 390 | 350 | 320 | 28 | 3 | 12-Ф23 |
300 | 698 | 400 | 814 | 440 | 400 | 368 | 28 | 4 | 12-Ф23 |
350 | 787 | 450 | 855 | 500 | 460 | 428 | 30 | f | 16-Ф23 |
Main connection and dimensions(PN16)
nominal diameter
| Main connection dimensions and connection dimensions |
Body connecting dimensions | Flange connection size |
L | D0 | H | D | D1 | D2 | b | f | Z-Фd |
15 | 130 | 100 | 265 | 95 | 65 | 45 | 14 | 2 | 4-Ф14 |
20 | 150 | 100 | 270 | 105 | 75 | 55 | 16 | 2 | 4-Ф14 |
25 | 160 | 120 | 275 | 115 | 85 | 65 | 16 | 2 | 4-Ф14 |
32 | 180 | 140 | 290 | 135 | 100 | 78 | 18 | 2 | 4-Ф18 |
40 | 200 | 140 | 320 | 145 | 110 | 85 | 18 | 3 | 4-Ф18 |
50 | 230 | 160 | 335 | 160 | 125 | 100 | 20 | 3 | 4-Ф18 |
65 | 290 | 180 | 400 | 180 | 145 | 120 | 20 | 3 | 4-Ф18 |
80 | 310 | 240 | 450 | 195 | 160 | 135 | 22 | 3 | 8-Ф18 |
100 | 350 | 240 | 495 | 215 | 180 | 155 | 24 | 3 | 8-Ф18 |
125 | 400 | 280 | 560 | 245 | 210 | 185 | 26 | 3 | 8-Ф18 |
150 | 480 | 320 | 650 | 280 | 240 | 210 | 28 | 3 | 8-Ф23 |
200 | 600 | 360 | 770 | 335 | 295 | 265 | 30 | 3 | 12-Ф23 |
250 | 650 | 400 | 810 | 405 | 355 | 320 | 32 | 3 | 12-Ф25 |
300 | 750 | 400 | 845 | 460 | 410 | 375 | 34 | 4 | 12-Ф25 |
Main part material
material code | Valve body, valve cover, gate valve clove | stem | lining layer | filler | stem mut |
Z | HT250 Gray cast iron | 35# | FEP/PFA/FCTFE | PTFE | ZQAL 9-4 |
C | WCB carbon steel | 1Cr13 |
P | CF8(304) stainless steel | 304 |
R | CF8M(316)stainless steel | 316 |
Other special materials, our company can also be tailored to customer needs.
valve body |
shell material | Applicable medium | Applicable temperature(℃) |
Gray cast iron(Z type) | Water, steam, oil
| ≤200 |
carbon steel(C type) | Water, steam, oil | ≤425 |
Ci Ni Ti(P typr) | Nitric acid | ≤200 |
Ci Ni Mo Ti Steel(R type) | Nitric acid | ≤200 |
lining layer |
material | Applicable medium | Applicable temperature(℃) |
FEP(F46)Poly ethylene propylene | In addition to the molten alkali metals, fluorine and aromatic hydrocarbons hydrochloric acid, sulfuric acid, aqua regia, organic acid, strong oxidizing agents, concentrated and dilute acid alternate, alternating alkaline and various organic solvents. | ≤150 |
PFA Soluble PTFE | ≤180 |
FCTFE Poly three fluoride | ≤190 |
Nominal pressureMPa | housing(MPa) | Test pressure(MPa) | Upper test pressure(MPa) |
seal(liqiud) | seal(gas) | seal(liqiud) |
1.0 | 1.5 | 1.1 | 0.6 | 1.1 |
1.6 | 2.4 | 1.76 | 0.6 | 1.76 |
Implementation standards
Design criteria: GB/T12233 HG/T3215 GB/T12235
Structure length: GB/T12221
Connecting flange: JB/T79, GB/T9113, HG/T20592, HG/T20615
Experiment and test: GB/T13927
Pressure - temperature: GB/T9131
Product label: GB/T12220
Storage and maintenance
Valves can be stored in any area of the mask, but must pay attention to prevent the valve is soil or ground dirty. At the time of shipment, the inlet and outlet of the valve are provided with a protective cover. Note that before the installation of the valve, do not remove these protective cover.
Installation and maintenance
1 before installation should be carefully check valve nameplate content, to ensure that the valve type, size, seat materials, temperature rated values in line with the use of pipeline.
2 rubber lining layer or rubber diaphragm surface fat items are not brushing, so as to avoid affecting the service life of the valve rubber swelling.
3 before the installation of the valve can be used to check all the connections at the valve to ensure that it has been evenly tightened. And check whether the packing is pressed and sealed.
4 in the manual operation of the valve, the valve should not be assisted by the use of the valve opening and closing, so as to avoid excessive torque and damage to the parts or parts of the seal.