Test current:200A The circuit resistance was directly measured by dc 200A recommended by national standard Accurate measurement, stable performance, The resolution of The high
Product Introduction
At present, the contact resistance measurements of the conventional type QJ44 arms widely used in electric power system dc bridge, and the Test of this kind of bridge current only mA level, it is difficult to find circuit conductor cross-sectional area to reduce defects, when measuring contact resistance high-voltage switch electric circuit, due to the contact between the oil film and the influence of the oxide layer, several times the measured value is big, can't reflect real contact resistance.To this end, the ministry of power standards.88 "ac 500kV power equipment handover and preventive test regulations" and the new "preventive test regulations for power equipment" stipulate that the measuring current of circuit breaker and isolating switch contact resistance is not less than dc 100A to ensure the accuracy of test results.
Contact resistance tester is designed according to The People's Republic of China electric power implementation standard DL/ t845.4-2004, using high frequency switch The power supply technology and digital circuit technology combined.Contact resistance tester is applicable to the measurement of circuit resistance of switch control device.Its Test current USES 100A and 200A dc recommended by national standards.The circuit resistance can be directly measured at the current of 100A or 200A, and the final test results are displayed in figures.The instrument is accurate in measurement and stable in performance. It meets the requirements of high voltage switch maintenance and resistance test of high voltage switch factory circuit.
Product names:Contact resistance tester、 switchMicro Ohmmeter、Contact Micro Ohmmeter, contact (circuit) resistance tester
Product Parameters
Technical parameters
| Measuring range | 1~1999μΩ |
| Resolution | 1μΩ |
| Test current | DC50A、100A、150A、200AFour speed fixed output |
| Accuracy | 0.5%±1d |
| Way to work | The connection |
| Display | Three and a half LCD |
| Power supply | AC220V±10% 50Hz |
| Working environment | Temperature -10℃ ~ 40℃, humidity: ≤80%RH |
| Diemension | 370(L)×320(W)×260(H) mm3 |
| Weight | 9.6kg(excluding attachments) |
Note: 1.The appearance of the product is subject to the actual product. Technical parameters and models are subject to change without prior notice.In case of misappropriation or copying, legal liability will be investigated.
2.For more information about huatian products, please enter Product center .Service :qiao@hvtest.cc
Product Characteristics
1、High current: using The new power supply technology, Contact resistance tester can continuously output high current for a long time, overcome The disadvantage of impulse The power supply instantaneous current, can effectively break through The switch Contact oxidation film, get good test results
2、Strong anti-interference ability: under The condition of serious interference, The last digit data of LCD can be stable within ±1 word of The scope of, with stable reading and good repeatability
3、Long service life: all use high precision resistance, effectively eliminate The influence of The environment temperature on The measurement results, at The same time, The use of military connector enhances The anti-vibration performance
4、Easy to carry: small volume、The weight of The weight of The weight
The product video Product Video